Selects the time unit in minutes, seconds or hours in the desired unit. In default settings, “minute” is selected.
Output menu enables different relay outs according to different set values. There are 11 different output
type. For detailed information refer to Annex-A part at the end of the manual. In order to select output
mode, pressed to prg button at operation mode. Found to output menu with up-down button and pressed
to prg button then bottom row choice flashes. Assigned value with up-down button and saved value by
prg button. Then return with rst button to operating mode.
4.7. Relay Output Modes (Output)
PRG
The relay function is turned off.
When passed over Set1 value, Output1 will be
active.
When passed over Set2 value, Output2 will be
active.
When passed over Set1 value, Output1 will be
active.
When passed over Set2 value, Output2 will be
active. Counter will be Hold position as long as
without reset.
When passed over Set1 value, Output1 will be
active.
When passed over Set2 value, Output2 will be
active. So Output1 is not active.
When passed over Set1 value, Output1 will be
active.
When passed over Set2 value, Output2 will be
active. Out1 will be inactive and the value on the
screen returns to the ofset value.
When passed over Set1 value, Output1 will be
active.
When passed over Set2 value, Output2 will be
active. Out1 is not active. And then and the
value on the screen returns to the ofset value.