Page
8
4.3 GENERAL OPERATION WITH SYSTEM 55
SYSTEM 55 is an IBM Compatible, Windows based proprietary EMC susceptibility program
specially designed to integrate the CMX25 with other IFI equipment into an efficient and flexible
automated EMC Testing System for immunity testing. It is capable for IEC801-3 testing as well
as a real time leveled sweep that maintains a desired preset field level across a given frequency
range.
4.4 GENERAL SPECIFICATIONS
The specifications listed below represent the minimum performance characteristics at the time of
delivery.
SPECIFICATIONS
Frequency Response:
Band One:
10 kHz to 250 MHz
Band Two:
200 MHz to 1000 MHz
Bandpass Ripple:
+ 2 dB maximum
Power Output:
Minimum 25 Watts, 20W min. at <1 dB gain compression
Power Gain:
50 dB (minimum)
Input Impedance:
Nominal 50 Ohms unbalanced
Output Impedance:
Nominal 50 Ohms unbalanced
Input Signal Levels:
< 0 dBm ( 1.0 mW ) See data sheet for specific input drive
levels
Harmonic distortion:
< -20 dB at 20 Watts (Typically < -30 dB)
Gain Adjustment:
Greater than 40 dB (voltage controlled) when using Level
Adjust.
Duty Factor:
No limitation
RF Rise Time:
Approximately 3 ns
Power Requirements:
5 to 10 Amps ( less than 1.0 KVA )