Television and Audio Suggestions 

Although these inverters are shielded and filtered to minimize signal interference, some 

interference with your television picture may be unavoidable, especially with weak signals. 

However, here are some suggestions that may improve reception. 

1.  First, make sure that television antenna produces a clear signal under normal operating 

conditions. Also, ensure that the antenna cable is properly shielded and of good quality. 

2.  Change the positions of the inverter, antenna cables and television power cord. 

3.  Isolate the television, its power cord and antenna cables from the 12 volt power source by 

running an extension cord from the inverter to the television set. 

 

4.  Coil the television power cord and the input cables running from the 12 volt 

power source to the inverter. 

5.  Attach a "Ferrite Data Line Filter" to the television power cord. More than one filter may be 

required. These filters are available at most electronic supply stores. 

Note: 

z

  Inexpensive sound systems may emit a "buzzing" sound when operated with the inverter. 

This is due to inadequate filters in the sound system. There is no solution to this problem 

short of purchasing a sound system with a higher quality power supply. 

 

Operating a Microwave oven with Your Power Inverter 

The power rating used with microwave ovens is the "cooking power" which qualifies as the 

power being "delivered" to the food being micro waved. The actual operating power 

requirement rating is higher than the cooking power rating. This is usually referenced on 

the back of the microwave. If the operating power requirement cannot be found on the back of 

the microwave, check the owner's manual or contact the manufacturer. 

Safety Precautions. 

For best results place the power inverter on a reasonably flat surface. 

z

 

Keep the inverter dry. Do not expose it to rain or moisture. 

DO NOT operate the inverter if the inverter, device being operated or any other surfaces 

that may come in contact with any power source are wet. Water and many other liquids can 

conduct electricity, which may lead to serious injury or death. 

z

 

Avoid placing the inverter on or near heating vents, radiators or other sources of heat. Do 

not leave the inverter in the passenger compartment of your vehicle. Store in a cool dry 

place. Do not place the inverter in direct sunlight. Ideal air temperature should be between 

50°F and 80°F. 

z

 

In order to properly disperse heat generated while the inverter is in operation, keep it well 

ventilated. While in use, maintain several inches of clearance around the top and sides of 

the inverter. 

z

 

Do not use the inverter near flammable materials. Do not place the inverter in areas such 

as battery compartments where fumes or gases may accumulate. 

 

 

 

 

 

Содержание ATD-5956

Страница 1: ...r running time and extended battery life Inverters convert low voltage direct current DC to 110 volt alternating current AC Depending on the model and its rated capacity the inverters draw power eithe...

Страница 2: ...it while testing appliances and equipment with ratings in the 3000 watt range If an appliance in the 3000 watt range will not operate properly when first connected to the inverter turn the inverter ro...

Страница 3: ...ing fans When the temperature inside the inverter exceeds the limits of safe operation the Cooling Fan automatically turns on to cool the inverter When the temperature has lowered to a safe operating...

Страница 4: ...ort burst of electrical power required to start combustion engines Using an inverter will cause a battery to discharge and recharge often We recommend that you use a different type of battery that is...

Страница 5: ...explosion 3 Locate the Ground Lug Terminal at the rear of the inverter Run a wire from this terminal to a proper grounding point using the shortest practical length 2 AWG wire or as described on the l...

Страница 6: ...wer Inverter The power rating used with microwave ovens is the cooking power which qualifies as the power being delivered to the food being micro waved The actual operating power requirement rating is...

Страница 7: ...r output the meters will read about 20 to 30 volts too low To accurately measure of the output voltage of the inverter use a true RMS reading voltmeter such as a Fluke 87 Fluke 8060A Beckman 4410 Trip...

Страница 8: ...n the inverter OFF immediately Do not restart the inverter until the source of the problem has been identified and corrected z To avoid battery drain always disconnect the inverter when not in use z D...

Страница 9: ...rter to cool Check for adequate ventilation Reduce the load on the inverter to rated continuous power output Reason Unit may be defective Solution See Warranty and call customer service PROBLEM TV Int...

Страница 10: ...ent Draw 2A Waveform Modified Sine Wave Input Voltage Range DC10 15V AC Receptacles 110V AC 3 prong grounded Fuse 12 x 30 amp spade type Dimensions 501Lx230Wx155Hmm 19 72 x 9 06 x 6 10 Weight 24Ib INV...

Отзывы: