2

 

Multiply: AMPS X 110 (AC voltage) = WATTS 

This formula yields a close approximation of the continuous load of your appliance 

 

Multiply: WATTS X 2 = Starting Load 

This formula yields a close approximation of the starting load of your appliance. Most often the 

start up load of the appliance or power tool determines whether your inverter has the capability 

to power it. 

 

To determine whether the inverter will operate a particular piece of equipment or appliance, run 

a test. The inverters are designed to automatically shut down in the event of a power overload. 

This protection feature prevents damage to the unit while testing appliances and equipment 

with ratings in the 3000 watt range. 

If an appliance in the 3000 watt range will not operate properly when first connected to the 

inverter, turn the inverter rocker switch ON(I), OFF(0), and ON(I) again in quick succession. If 

this procedure is not successful, it is likely that the inverter does not have the required capacity 

to operate the appliance in question. 

 

Important 

z

  The inverter is designed to operate from a 12-volt power source only. Do not attempt to 

connect the inverter to any other power source, including any AC power source. 

z

  Do not attempt to extend or otherwise modify the 12-volt power cord attached to your 

inverter. 

z

 

110 volts of current can be lethal. Improper use of your inverter may result in property 
damage, personal injury or loss of life.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание ATD-5956

Страница 1: ...r running time and extended battery life Inverters convert low voltage direct current DC to 110 volt alternating current AC Depending on the model and its rated capacity the inverters draw power eithe...

Страница 2: ...it while testing appliances and equipment with ratings in the 3000 watt range If an appliance in the 3000 watt range will not operate properly when first connected to the inverter turn the inverter ro...

Страница 3: ...ing fans When the temperature inside the inverter exceeds the limits of safe operation the Cooling Fan automatically turns on to cool the inverter When the temperature has lowered to a safe operating...

Страница 4: ...ort burst of electrical power required to start combustion engines Using an inverter will cause a battery to discharge and recharge often We recommend that you use a different type of battery that is...

Страница 5: ...explosion 3 Locate the Ground Lug Terminal at the rear of the inverter Run a wire from this terminal to a proper grounding point using the shortest practical length 2 AWG wire or as described on the l...

Страница 6: ...wer Inverter The power rating used with microwave ovens is the cooking power which qualifies as the power being delivered to the food being micro waved The actual operating power requirement rating is...

Страница 7: ...r output the meters will read about 20 to 30 volts too low To accurately measure of the output voltage of the inverter use a true RMS reading voltmeter such as a Fluke 87 Fluke 8060A Beckman 4410 Trip...

Страница 8: ...n the inverter OFF immediately Do not restart the inverter until the source of the problem has been identified and corrected z To avoid battery drain always disconnect the inverter when not in use z D...

Страница 9: ...rter to cool Check for adequate ventilation Reduce the load on the inverter to rated continuous power output Reason Unit may be defective Solution See Warranty and call customer service PROBLEM TV Int...

Страница 10: ...ent Draw 2A Waveform Modified Sine Wave Input Voltage Range DC10 15V AC Receptacles 110V AC 3 prong grounded Fuse 12 x 30 amp spade type Dimensions 501Lx230Wx155Hmm 19 72 x 9 06 x 6 10 Weight 24Ib INV...

Отзывы: