ATD Tools ATD-5953 Скачать руководство пользователя страница 6

 

6

Television and Audio Suggestions 

Although these inverters are shielded and filtered to minimize signal interference, some 

interference with your television picture may be unavoidable, especially with weak signals. 

However, here are some suggestions that may improve reception. 

1.  First, make sure that television antenna produces a clear signal under normal operating 

conditions (i.e., at home plugged into a standard 110V AC wall outlet). Also, ensure that the 

antenna cable is properly shielded and of good quality. 

2.  Change the positions of the inverter, antenna cables and television power cord. 

3.  Isolate the television, its power cord and antenna cables from the 12-volt power source by 

running an extension cord from the inverter to the television set. 

4.  Coil the television power cord and the input cables running from the 12-volt power source to 

the inverter. 

5.  Attach a "Ferrite Data Line Filter" to the television power cord. More than one filter may be 

required. These filters are available at most electronic supply stores. 

 Note: 

z

 

Inexpensive sound systems may emit a "buzzing" sound when operated with the inverter. 

This is due to inadequate filters in the sound system. There is no solution to this problem 

short of purchasing a sound system with a higher quality power supply. 

 

Inverter Protection Features. 

The RED LED Indicator light will turn on and the inverter will turn itself off automatically when: 

1.  The power input from the battery drops to 9.5 volts.(When the power input drops to 10.5 

volts, an alarm will sound for an extended period). 

2.  The power input from the battery exceeds 15.5 volts. 

3.  The continuous draw of the equipment or appliance being operated exceeds 800 watts. 

4.  The surge draw of the equipment or appliance being operated exceeds 1600 watts. 

5.  The circuit temperature exceeds 165°F. 

 
Note: 

z

 

The inverter is equipped with a cooling fan, which is designed to run continuously while the 

inverter is operating. Automatic shut down caused by high circuit temperatures will occur 

when the cooling fan is unable to maintain a cool enough temperature for safe operation of 

the inverter. 

z

 

In the event of automatic shut down or continuous audible alarm, turn the inverter rocker 

switch to the OFF(0) position until the source of the problem has been determined and 

resolved. 

 

Safety Precautions. 

For best results place the power inverter on a reasonably flat surface. 

z

 

Keep the inverter dry. Do not expose it to rain or moisture. 

DO NOT operate the inverter if the inverter, device being operated or any other surfaces that 

may come in contact with any power source are wet. Water and many other liquids can 

conduct electricity, which may lead to serious injury or death. 

z

 

Avoid placing the inverter on or near heating vents, radiators or other sources of heat. Do 

Содержание ATD-5953

Страница 1: ...g h e s t e f f i c i e n c y a v a i l a b l e u p t o 9 0 which translates into longer running time and extended battery life Inverters convert low voltage direct current DC to 110 volt alternating...

Страница 2: ...has the capability to power it To determine whether the inverter will operate a particular piece of equipment or appliance run a test The inverters are designed to automatically shut down in the even...

Страница 3: ...curs turn off the inverter and determine the cause of the over load before turning the inverter and the appliance back on C Two Standard North American 110V AC Outlets D High Speed Cooling Fan When th...

Страница 4: ...periods it is not advisable to power the inverter with the same battery used to power your car or truck If the car or truck battery is utilized for an extended period it is possible that the battery...

Страница 5: ...ake certain that the inverter is turned off Operating the inverter without correctly grounding the unit may result in electrical shock 4 Turn On I the inverter Make certain that the Over Load LED Indi...

Страница 6: ...Protection Features The RED LED Indicator light will turn on and the inverter will turn itself off automatically when 1 The power input from the battery drops to 9 5 volts When the power input drops...

Страница 7: ...nced MOSFET Metal Oxide Semiconductor Field effect Transistor transistors in a full bridge configuration This design provides all our inverters with the capability to start and run difficult reactive...

Страница 8: ...chargers monitor the temperature of the battery charger for approximately 10 minutes If the battery charger becomes abnormally warm disconnect it from the inverter immediately z When operating the inv...

Страница 9: ...rter to cool Check for adequate ventilation Reduce the load on the inverter to rated continuous power output Reason Unit may be defective Solution See Warranty and call customer service PROBLEM TV Int...

Страница 10: ...A larger inverter may be required SPECIFICATION Max Continuous Power 1000 Watts Surge Capability Peak Power 2000 Watts No Load Current Draw 0 9A Waveform Modified Sine Wave Input Voltage Range DC10 15...

Страница 11: ...BATTERY CABLES 800W OR GREATER MUST BE HARD WIRED TO BATTERY USE THE THICKEST WIRE AVAILABLE IN THE SHORTEST LENGTH PRACTICAL Wattage 0 4 Length 5 10 Length 800W 2 AWG 0 AWG 1000W 0 AWG 2 0 AWG 1500W...