ATD Tools ATD-5953 Скачать руководство пользователя страница 11

 11

INVERTER CABLES 

 

200W & 400W COME WITH A CIGARETTE LIGHTER PLUG/CABLE

 

& CLAMP ON BATTERY CABLES 

 

800W OR GREATER MUST BE HARD WIRED TO BATTERY 

*USE THE THICKEST WIRE AVAILABLE IN THE SHORTEST LENGTH PRACTICAL 

 

Wattage 

0'-4' Length 

5'-10' Length 

  800W 

#2 AWG 

#0 AWG 

1000W #0 

AWG  #2/0 

AWG 

1500W #0 

AWG  #2/0 

AWG 

2000W 

#2/0 AWG 

#4/0 AWG 

3000W 

#2/0 AWG 

#4/0 AWG 

6000W 

#2/0 AWG 

#4/0 AWG 

 

 

Содержание ATD-5953

Страница 1: ...g h e s t e f f i c i e n c y a v a i l a b l e u p t o 9 0 which translates into longer running time and extended battery life Inverters convert low voltage direct current DC to 110 volt alternating...

Страница 2: ...has the capability to power it To determine whether the inverter will operate a particular piece of equipment or appliance run a test The inverters are designed to automatically shut down in the even...

Страница 3: ...curs turn off the inverter and determine the cause of the over load before turning the inverter and the appliance back on C Two Standard North American 110V AC Outlets D High Speed Cooling Fan When th...

Страница 4: ...periods it is not advisable to power the inverter with the same battery used to power your car or truck If the car or truck battery is utilized for an extended period it is possible that the battery...

Страница 5: ...ake certain that the inverter is turned off Operating the inverter without correctly grounding the unit may result in electrical shock 4 Turn On I the inverter Make certain that the Over Load LED Indi...

Страница 6: ...Protection Features The RED LED Indicator light will turn on and the inverter will turn itself off automatically when 1 The power input from the battery drops to 9 5 volts When the power input drops...

Страница 7: ...nced MOSFET Metal Oxide Semiconductor Field effect Transistor transistors in a full bridge configuration This design provides all our inverters with the capability to start and run difficult reactive...

Страница 8: ...chargers monitor the temperature of the battery charger for approximately 10 minutes If the battery charger becomes abnormally warm disconnect it from the inverter immediately z When operating the inv...

Страница 9: ...rter to cool Check for adequate ventilation Reduce the load on the inverter to rated continuous power output Reason Unit may be defective Solution See Warranty and call customer service PROBLEM TV Int...

Страница 10: ...A larger inverter may be required SPECIFICATION Max Continuous Power 1000 Watts Surge Capability Peak Power 2000 Watts No Load Current Draw 0 9A Waveform Modified Sine Wave Input Voltage Range DC10 15...

Страница 11: ...BATTERY CABLES 800W OR GREATER MUST BE HARD WIRED TO BATTERY USE THE THICKEST WIRE AVAILABLE IN THE SHORTEST LENGTH PRACTICAL Wattage 0 4 Length 5 10 Length 800W 2 AWG 0 AWG 1000W 0 AWG 2 0 AWG 1500W...