8
1. When the battery
charge falls below
the first level on
the LCD, the fixed
battery symbol
appears. In this
condition, the
meter continues to operate correctly, but
the fixed icon warns the user that it is time to
change the batteries.
Changing the battery
The meter features two low-battery alarm levels
12,345
Q
TS
G
AL
2342,3
TOTAL
6. By pressing CAL
key, the Meter
value changes
in the direction
indicated by the
arrow,
• one unit for every short press of CAL key.
• continually if the CAL key is kept pressed.
The speed increase rises by keeping the
key pressed.
7. Press RESET key
for more than 2
seconds. The meter
detects that the
desired reading
has been set and
the calibration
procedure is finished.
8. At the end of
the calculation,
the new USER K
FACTOR is shown
for a few seconds.
9. The restart cycle is
repeated to finally
achieve standby
mode.
1,003
Cal END
1,003
Cal DIRECT
-----
Cal DIRECT
TOTAL
12.5
0,000
contact with the control outlet
• Always cut off air supply after use, so that
media cannot leak in case any of the pump
component fails
• Before switching the air supply on, check
hoses for sign of wear, leak or loose fittings.
Replace as necessary
• Do not smoke near the pump. Do not use the
pump near a source of spark / open flames
• When changing the working fluid, at least 1
litre of new fluid should be discarded to avoid
mixing of fluids
• Pump should NOT be operated for more than
4 hours continuously
• Pump must be supplied with clean & dry
compressed air via an FRC unit
• Before attempting any repair of this product,
disconnect air supply and then squeeze
control valve trigger to release fluid pressure
MAINTENANCE
Every week clean the FRC (Filter-Regulator
Combination) unit and high pressure hose so the
pump remains free from contamination.
The Oil Control Gun has been designed to require
a minimum amount of maintenance.
The only maintenance jobs required are:
Battery change for meter:
Necessary when the
batteries have run down
Cleaning the measurement chamber:
Necessary
due to the particular nature of the dispensed
fluids or due to the presence of solid particles
following bad filtering.
2. If meter operation
continues without
changing the
batteries, the
second battery
alarm level will be
reached which
will prevent operation. In this condition the
battery icon starts to flash and is the only one
to remain visible on the LCD.
OPERATING INSTRUCTIONS
1. Partially open the on/off air valve (It helps
in creating initial vacuum when filling a
totally dry pump). Pump will start operating
automatically until it gets primed. Pump is
said to be primed when oil is available at the
pump outlet, making the pump ready to use.
Once primed, the air motor will stop. Open the
on/off air valve fully.
2. Hold the oil control gun near a container &
press the trigger. Pump will start operating
with continuous oil discharge as long as the
trigger is pressed. Release the trigger & this will
stop the pump. Check for any leaks from any
of the connections & tighten again if required.
3. Once the trigger is released, pump will stop
dispensing oil & the air motor will stop.
4. When not in use & at the end of each day, air
supply to the pump must be switched off.
WARNING!
• Always wear protection gear like safety
goggles, gloves, apron, and ear plugs while
operating the pump
• Never let any body part come in front of, or in