ATC W10-u Скачать руководство пользователя страница 4

-4-

ATC Electrical & Mechanical, 

ATC House, Broomhill Drive, Tallaght, D24 EF99, Ireland

IE: 01 4678301, UK:0203 564 9164, Email [email protected]

GENERAL WIRING DIAGRAM 

HEATER MOUNTING INSTRUCTIONS

45

45

14

66

Concrete or Brick

Timber or Plaster

Hang the heater on the 

Bracket

The water heater should be installed close to a water drainpipe so that excess water from 

the safety relief valve can drain away without harm; this drain pipe should always be kept 

free of obstruction.

Fix the mounting bracket supplied with the heater to the wall; see below for dimensions 

of the holes required; always use screws that are suitable for the wall material and the 

weight of the heater otherwise the heater may pull the bracket off the wall.

Hang the water heater on the bracket.

Tug downwards on the heater to ensure that both “fingers “of the bracket are seated in 

the mounting slots. 

The heater can also be stood on its base using the rubber feet provided for this purpose.  

Attach the four adhesive feet to the base of the heater before plumbing.

Confirm water piping orientation before wall mounting.

Note: If using the rubber feet, it is not neces-
sary to  use the wall bracket also. 
Should the installer wish to use the bracket as 
an additional fixing method, confirm location 
of bracket with feet attached to heater prior to 
installation.

Содержание W10-u

Страница 1: ...Ireland IE 01 4678301 UK 0203 564 9164 Email sales atc ie 1 ATC PACIFIC WATER HEATING INSTALLATION AND OPERATION MANUAL W5 u 5 Litre Undersink water heater W10 u 10 Litre Undersink water heater W15 u...

Страница 2: ...examine and if necessary replace the anode rod at least once a year could cause the tank to fail and leak and void the warranty 8 Cable connection should be to a 13A double pole Switched Spur 9 This...

Страница 3: ...nter 100 Thermostat Type Capillary type Thermostat Range C Min C Max 30 80 35 75 External Switch No Yes Heating Indicator LED Yes Installation location Undersink wall mounted or standing on rubber fee...

Страница 4: ...the holes required always use screws that are suitable for the wall material and the weight of the heater otherwise the heater may pull the bracket off the wall Hang the water heater on the bracket Tu...

Страница 5: ...dation must be made for the expanded water that will occur with each operating cycle Regulations permit expanded hot water to be accommodated within the supply pipe work provided that an expansion rel...

Страница 6: ...in the pipework is not possible An expansion vessel must be used Cold in Hot out 5 10 or 15 Ltr Water heater CLOSED SYSTEM THERMAL EXPANSION There is a Pressure relief safety valve supplied with the...

Страница 7: ...rs shall only switch on off the water heater provided that it has been installed in its intended normal operating position and they have been given instruction concerning use of the heater in a safe w...

Страница 8: ...oint outlined above check the water tempera ture do not place hands directly under water outlet as there could be a risk of scalding If it is necessary to adjust thermostat turn the dial clockwise to...

Страница 9: ...acidity alkalinity in the water supply To replace the Anode 1 Turn off the power supply and drain the heater see previous section 2 Remove heating element see previous section 3 Remove the spent anod...

Страница 10: ...thermostat to desired setting Note a lower setting is more economical and reduces the risk of scalding CAUTION Call a technician if the high limit needs to be reset frequently 5 Litre Hi Level Reset...

Страница 11: ...heater is not suitable for use on gravity fed systems Unit Leaking 1 Check water connection fittings at the top of tank ensure the connections to the water heater are sound and are not the cause of th...

Страница 12: ...65 ERP RATING INFORMATION Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking shown on the product or its...