VARENA
8
A73023342
Connecting wires:
Brown:
Live
Blue:
Neutral
Yellow-Green: Earth
The connecting wires must be of the appropriate cross section, with regard to the length of cable,
type of cable and power rating of the appliance.
The appliance must be connected into a
fused
connection box fitted with an appropriately sized
fuse for the radiator (see Characteristics Table on page 15). We recommend that the connecting
box is positioned 10 cm to the right of the appliance and 40 cm above the floor.
According to regulations, the appliance must be connected to the power supply by means of an
all-pole circuit breaker with a contact gap of at least 3 mm or by a thermal-magnetic circuit
breaker. It is recommended to install the heaters on a circuit protected by an RCBO.
4. MOUNTING
The electric radiator should be fixed to the wall by the adjustable brackets supplied with the
radiator, using the cardboard template printed on the box.
If for any reason cardboard template is missing, you can follow the instructions below:
1. Place the two metal brackets provided on the floor and against the wall as shown in image
1 below. Ensure the MB stamp on the metal bracket is at the top.
2. Check Table 1 for the “A” distance between the brackets for your VARENA model.
3. Mark the small hole in the metal brackets on the wall with a pencil. These two marked
points determine the position of the two lower drill holes.
4. With the help of a level, position the brackets matching their lower holes with the previously
marked points and mark the upper holes with the pencil.
1
Model
A (mm)
VARENA 500
160
VARENA 750
240
VARENA 1000
320
VARENA 1200
400
VARENA 1500
400
VARENA 1800
720
Table 1
Содержание VARENA 1000