Installation instructions AQUAmax
®
BASIC/CLASSIC 1-75
ATB WATER GmbH, Südstraße 2, D-32457 Porta Westfalica, www.atbwater.com /
Art.-No.: 9060 0209 / Status: 17.01.2019 / Page 14 from 24
Installing AQUAmax
®
A communicating tube forms the connection to the primary chamber. This system
works only with absolute tightness! Please ensure that cables and hoses are long
enough so that the AQUAmax® can be easily take out of the tank. Cables must not be
subjected to tensile stress.
AQUAmax
®
BASIC, CLASSIC M
AQUA
max
®
BASIC, CLASSIC M are placed centrally on the partition wall. The immersion pipe
must dip into the 2
nd
primary settling chamber (not the inlet chamber). With single-chamber primary
settling an additional protective pipe or a scum board is to be provided for the immersion pipe.
Connect the outlet hose with the AQUA
max
®
by means of a coupler connection.
AQUAmax
®
CLASSIC Z / ZB
With the
AQUA
max
®
CLASSIC Z
push the 30 respectively 40 mm PVC hose through the
connecting pipe to the primary settling stage and, using the coupler connection screw on to the
sludge pipe. Lay the hose in such a way that this does not sag. Secure the sludge pipe using the
enclosed pipe clips such theat the inlet opening is at the height of H
W,min
. Connect PVC hose and
immersion pipe by means of the enclosed hose clips. If required, the immersion pipe must be
secured against the ingress of thick matter floating sludge (see below).