Manual for use of thermo-hygro-barometer COMMETER C4141 with external 

probe 

 

Instrument is designed for measurement of temperature, relative humidity, atmospheric 

pressure and pressure tendency. It enables to display the dew point temperature and atmospheric 
pressure corrected to the sea level. Measured values are displayed on a dual line LCD display. 
Temperature is measured by RTD sensor Ni1000/6180ppm. Instrument is equipped with an 
external temperature - relative humidity probe. Instrument compares all measured values (except 
pressure tendency) with two adjustable levels for each measured quantity. Breaking the level is 
indicated by  blinking the proper value on display and by audio indication (switchable). Instrument 
is equipped with minimum and maximum memory and Hold function. Minimum and maximum 
values and Hold value are possible to display on the LCD anytime. 
 

Technical parameters: 

 

Parameters of measurement: 

 

  Temperature: Range of measurement: internal sensor (INT) -10 to +60 °C 

external sensor (EXT) -30 to +105 °C (temperature 

from +85 to +105°C with the limitation accordingly to the graph below)  

   Resolution: 

0.1 

°C 

   Accuracy: 

±0.4 

°C 

 

  Humidity: 

Range measurement: 0 to 100 %RH 

   Resolution: 

0.1 

%RH 

  

 

Accuracy: ±2.5 % RH at the range of 5 to 95 %RH 

 Dew point temperature (calculated from temperature and humidity): 
  

 

Range: -50 to +60 °C 

   Resolution: 

0.1 

°C 

 

 

 

Accuracy: ±0.5 °C at the range of 30 to 95 % RH 

 

Atmospheric pressure: Range of measurement: 800 to 1100hPa 

Resolution: 0.1 hPa 

 

 

 

Accuracy: ± 2hPa at ambient temperature of 23°C 

Measuring interval and display reading refresh: approximately 0.7 s in FAST mode 

  

 

 

 

 

 

        

                0.7 to 5 s in dynamic mode 

 

Interval of  refresh of pressure tendency display: 0.5 h  
Power: battery 9V or ac/dc adapter 12V with NiCd accumulator 9V 

 

Typical life of Zinc-Chloride battery: 2 months 
Typical life of Alkali-Mangan battery: 3 months  
 
Average current consumption: 0.3 to 1.3 mA (depending on operation mode) 

 Operation 

conditions: 

 

  Ambient temperature range: -10 to +60 °C 

 

  Ambient relative humidity range: 5 to 95 %RH 

Outer characteristics in accordance with EN 33-2000-3: normal environment with   
characteristics AD1, AE1, AF1, AG1, AH1, AK1, AL1, AN1, AP1, AQ1, AR1, 
AS1, BA1, BE1 

 

Not allowed manipulation: it is not allowed to touch sensors under the cover to avoid  

 

 

sensors damaging or to effect calibration. 

 

The sensors (under the cover) should not be exposed to direct contact with water or other 
liquids.  

 

Storing conditions: temperature -10 to +60 °C relative humidity 5 to 95 %RH 

 

Dimensions: 141 x 71 x 27 mm 

Содержание COMMETER C4141

Страница 1: ...COMMETER C4141 Digital thermo hygro barometer with external probe Instruction manual ...

Страница 2: ... 0 4 C Humidity Range measurement 0 to 100 RH Resolution 0 1 RH Accuracy 2 5 RH at the range of 5 to 95 RH Dew point temperature calculated from temperature and humidity Range 50 to 60 C Resolution 0 1 C Accuracy 0 5 C at the range of 30 to 95 RH Atmospheric pressure Range of measurement 800 to 1100hPa Resolution 0 1 hPa Accuracy 2hPa at ambient temperature of 23 C Measuring interval and display r...

Страница 3: ...internal 9V battery is replaced with rechargeable NiCd accumulator In usual operation from adapter accumulator is charged only with small current If accumulator is totally discharged its full charging in instrument takes approximately 100 hours Instrument with accumulator is not recommended for permanent operation without ac dc adapter plugged Accumulator works only as a standby source in case of ...

Страница 4: ...actual measured values and minimum a maximum memory Press HOLD key in the default mode displaying of actual measured value to store actual measured values to internal memory indicated by short beep Anytime it is possible to display stored values from MENU see below Each pressing of the HOLD key in the default mode causes values stored in HOLD memory are replaced with actual ones Switched ON instru...

Страница 5: ...partially loaded battery is displayed This value illustrates battery condition This selection by pressing ENTER key enables to enter mode of pressure correction to the sea level see below Display refresh mode is indicated In the FAST mode refreshment is fastest with regular interval approximately 0 7 s In the dynamic refresh mode DYN each 15 s refresh interval of display is doubled to maximum 5 s ...

Страница 6: ...measurement display starts to display the value out of limits If at least one alarm is active audio indication can be activated if menu AUDI On is selected see setting described above Alarm activation of each value can be disabled by setting lower alarm limit of the desired value up to its maximum This is indicated by OFF reading at the position of numeric value Value of upper limit of the same al...

Страница 7: ...cessary to replace battery with instrument switched OFF otherwise setting of d REF and AUDI from menu selections and data in memory HOLD MIN and MAX will be lost For the same reason do not disconnect the battery for longer than 1 minute even if instrument is switched OFF If it happens or if battery is totally discharged it is necessary to set again in appropriate menu selection LCD refreshment mod...

Отзывы: