12
In the case of using the power supply adapter PS-ATM, connect the white wire to positive pole and
the black wire to negative pole.
Connecting of power supply adapter PS-ATM
If the modem and the data logger ATP are operated in a vehicle, it will be necessary to use the
cable for voltage distribution between the data logger and the modem. For more detailed
information see the chapter
The data logger and the modem interconnection
4.3.4.
The data logger and the modem interconnection
The ATV or ATX data logger and the modem interconnection is provided with the
COM adapter
IP65
. Connect the adapter connector to the RS232 connector on the modem and plug the adapter to
the guide slots on the side of the data logger. Heed to keep a minimum distance between the
modem antenna and the data logger during installation to prevent the data logger interference. This
distance may not be in any case less than 50 centimeters. Keeping the distance at least 1 meter is
recommended. The correct way to connect is shown in the picture given below.
The ATV or ATX data logger, the modem and other accessories interconnection