Atag Q-Solar Скачать руководство пользователя страница 5

 Operating instructions ATAG Q-Solar

 Operating instructions ATAG Q-Solar

5

The ATAG Q-Solar boiler is a room sealed,
condensing and modulating central heating boiler
with an integrated hot water facility. The boiler uses
free solar energy for central heating and domestic
hot water.

The boiler anticipates the heat demand of the central
heating system or the hot water facility. As well as
for the heating system as for the domestic hot water
fascility solar heat from the cylinder is used first. The
solar heat is received by the absorber and
transferred to the water in the cylinder. When there
is insufficient sun light the boiler will switch on to
meet the heat demand. The boiler will anticipate its
power to the installation and will switch on as less
as possible. On this way the control strives for a
maximum of comfort and efficiency.

The boiler is provided with an intelligent control
system (CMS Control Management System).
To anticipate on installation noises the boiler is
provided with a so called gradient control. This
control takes care that when the boiler fires it does
not burn on full power, but slowly increases the
power. This taks care of an even increase of the flow
water temperature.

The absorber pump is activated if the temperature in
the absorber is approx. 10°C higher than the
temperature in the cylinder. The absorber pump
switches off automatically as soon as this
temperature difference has dropped to approx. 2°C.
The pump also switches off automatically as soon
as the cylinder has reached a temperature of 80°C.
The controller allows the pump to restart once the
temperature of the cylinder has dropped to 75°C.

Room sealed boiler
The boiler retreives its
combustion air from outside
then discharges the flue
gasses to the outside.

Condensing
Retrieves heat from the
flue gasses. Water
condensates on the heat
exchanger.

Modulating
Higher or lower burning
according to the heat
demand.

Stainless steel
Super  solid kind of steel
which keeps its quality for
life. It will not rust or erode in
contrast to composition
materials, like aluminium.

Description of the boiler

Anti-legionella and
solar cylinder
The adjustment of the
DHW flow temperature
must not be set lower than
60°C.

16

Adjustments

The boiler has a large number of settings options.
We advise you to contact your installer for
adjusting the boiler to the required settings.

Adjusting the flow water temperature (CH)

-

Press the Mode key briefly
(from the Technical reading).

The display will show PARA .

-

Press the Step key once.

The display will show 1  85 .

-

Press the + or the - key to alter the adjustments,
if necessary.

-

Press the Store key to confirm the setting.

The display will flash once.

-

Press the Mode key briefly.

The display will show StbY for a short while and
will return to the Technical reading.

The flow water temperature that has been adjusted

only applies to the central heating and is independent of the hot water facility for the
cylinder.

Содержание Q-Solar

Страница 1: ...tor for UK ATAG Heating UK Ltd Unit 3 Beaver Trade Park Quarry Lane Chichester West Sussex PO19 8NY Phone 01243 815 770 Fax 01243 839 596 E mail info atagheating co uk Internet www atagheating co uk Ditributor for Ireland Total Energy Management Ltd Unit 9 Ballybritt Industrial Estate Monivea Road Galway Ireland Phone 091 769174 Fax 091 769485 E mail info tem ie Internet www tem ie ...

Страница 2: ... Reset key 7 The boiler display 8 Water pressure in the central heating system 9 Replenishing the central heating 10 Turning the boiler off 12 Error maintenance and warranty 13 Adjustments 14 Important It is in your own interest that we should know that you have an ATAG boiler Please fill out the warranty card completely and send it back to us Then we can be fully at your service 19 ...

Страница 3: ...servicing instructions manual for the installer Readthismanualfullybeforeoperatingtheboiler In case of doubt or errors contact your installer ATAG Heating reserves the right to change the specifications and dimensions without prior notice Work on the boiler must be carried out by a competent person Ref Gas Safety Installation and Use using correctly calibrated instruments with current test certifi...

Страница 4: ...nal heating 60 C 04 full under floor heating 50 C factory setting Adjusting the type of installation The boiler is designed in such a way that it will adjust itself automatically to what is necessary for a normal heating system In some cases the installation may have convectors or complete underfloor heating One can easily choose heating installation adjustments appropriate for the system such as ...

Страница 5: ...s soon as this temperaturedifferencehasdroppedtoapprox 2 C The pump also switches off automatically as soon asthecylinderhasreachedatemperatureof80 C The controller allows the pump to restart once the temperature of the cylinder has dropped to 75 C Room sealed boiler The boiler retreives its combustionairfromoutside then discharges the flue gasses to the outside Condensing Retrieves heat from the ...

Страница 6: ...ertotheuser manual ATAG BrainQ Example SEDBUK ClassA Normally the pipes between absorber and cylinder are insulated However it needs your attention that the pipes during operation can be extreemly hot 120 C 15 Error maintenance and warranty If a fault is detected the boiler will be blocked This will be reflected by an alternate display of Good with an Eof Error or a BL of Blocking and a number cod...

Страница 7: ...od Adjust the thermostat to the holiday period See the BrainQ user manual The hot water facility can beswitchedoffbymeansoftheprogramkey on the control panel Re setting the central heating system Switch off the three program keys when these are activated Switch off the power supply When the boiler is being drained one should take into account that a part of the heating water will remain in the boi...

Страница 8: ...D s On the left side of the boiler there is a small door Throughthetransparentpartyoucanseetheboiler statusonthedisplay Afteropeningthisdooryouwill find the function keys On the right side of the door you will find an instruction card in a sleeve with an explanation of the display messages and function keys This is described below 13 The boiler will not function directly The automatic de aeration ...

Страница 9: ...ntact your installer 12 Replenishing the central heating system The central heating installation needs to be filled with potable drinking water For topping up the installation you use the filling loop according to the following procedure If in any doubt please contact your dealer 1 Switch all functions off heating DHW and pump 2 Briefly push the STEP button P x x water pressure in bar 3 Slowly ope...

Страница 10: ...essure in bar If a fault is found the same is shown as described under TheGoodreading Selecting the Technical or Good reading Press the Step key for 5 seconds The display will change from the Good reading to the technical reading or vice versa 11 Water pressure in the central heating system The installation will function optimally with a water pressure of between 1 5 and 1 7 bar Ifthewaterpressure...

Отзывы: