Parameter
number
Name
Description
Unit
Range
Default
Combi
4. ZONE 1 PARAMETERS (CONTINUED)
4.7 Zone 1 Regulation parameters (Continued)
( 4.7.1 Cont.)
2 = Medium
3 = Good
4.7.2
Building insulation level
0 = Poor
0 - 2
0
1 = Average
2 = Good
4.7.3
Building size
0 = Small
0 - 2
0
1 = Average
2 = Large
4.7.4
Climate Zone
Setting as a base for the heatline calculation
-60 to +50
-12
4.7.5
Auto slope adaptation
0 = Off 1 - On
0 - 1
0
4.7.6
Pre-heat Function
0 = Off 1 - On
0 - 1
1
5. SETTINGS ZONE 2 (SEE ZONE 1 CHAPTER 4)
6. SETTINGS ZONE 3 (SEE ZONE 1 CHAPTER 4)
8. SERVICE PARAMETERS
8.0 Boiler statistics - 1
8.0.0
diverter valve
Number of diverter valve cycles
times
xx
8.0.1
Pump
Number of running hours pump
h
xx
8.0.3
Boiler lifetime
Number of hours since 1st boiler power up.
h
xx
8.1 Boiler statistics - 2
8.1.0
Burner on CH
Number of hours burner active for CH
h
xx
8.1.1
Burner on DHW
Number of hours burner active for DHW
h
xx
8.1.3
Ignition
Number of ignition cycles
times
xx
8.2 Boiler
8.2.1
Fan status
Fan: 0 = OFF 1 = ON
8.2.2
Fan speed
Number of revolutions
Rpm
8.2.4
Diverter valve position
Position of the diverter valve 0 = DHW 1 = CH
8.2.5
DHW flowrate
l/min
8.2.7
pump modulation
%
8.2.8
gas power
Actual boiler power based on fan revolutions
kW
8.2.9
system pressure
bar
8.3 Boiler temperatures
8.3.0
CH T-Set
Calculated target flow temperature
°C
8.3.1
CH flow temperature
°C
8.3.2
CH Return temperature
°C
8.3.3
DHW Temperature
°C
8.3.4
flue gas temperature
Only if flue gas sensor is connected
°C
8.3.5
Outside temperature
Only if outside sensor is connected or connected to the internet
°C
8.4 Storage
8.4.0
N/A
8.4.2
N/A
8.5 Service
8.5.0
Months to next maintenance Months to go before next Maintenance warning comes up
0-60
12
8.5.1
Maintenance warning active Switch on or of the maintenance warning 0 = OFF 1 = ON
0 - 1
0
8.5.2
Maintenance warning reset
Reset the maintenance warning in the display and the timer
0 - 1
8.6 Error History
8.6.0
Error history
Overview of the last 10 errors occurred
8.6.1
Reset Error list
OK = Yes ESC = No
8.7 Free Parameter
8.7.5
Ionization Current
8.7.6
Safety Flame Sensor
Burner status of the boiler 0 = OFF 1 = ON
8.7.7
CH Flow switch State
0 = OFF 1 = ON
29