6
INITIAL ELECTRICAL INSTALLATION
CAUTION:
CABLES WHICH HAVE A GREEN/YELLOW COLOURED INSULATION ARE FOR
EARTHING PURPOSES ONLY. NEVER USE THESE CABLES FOR ANY OTHER PURPOSE.
SELECTING LEFT OR RIGHT HAND INSTALLATION.
Using the figure below, place the motor connector for the drive
unit so as to reflect the side of the doorway that it is installed.
NOTE:
The wiring diagram on Page 7 is for right hand
installation. If left hand installation is required - interchange the
brown and white either inside the pendant switch.
Left Hand
Right Hand
FIG. 5
FIG. 6