AT 3020 Скачать руководство пользователя страница 6

 

©2021 A+T                                                                                                                                           5

 

APPENDIX C

 

 

Mounting the 3020 display 

 

DO NOT USE Acetone or any alcohol based solvent agents for cleaning. 
These may damage the plastic materials on the display. 

 

Recommendations: 

a)  A 1mm clearance between the Analogue and the bulkhead cutout 
b)  Use the supplied gasket to mount on a clean, flat surface. 
c)  Should  you  require  additional  waterproofing,  or  are  mounting  on  a 

curved  surface,  use  a  bead  of  proprietry 

NON-ADHESIVE

  sealant 

instead of the supplied gasket and fasten using small spacers to achieve 
an even gasket without squeezing all the sealant out of the gap. 

a.  Once the sealant has cured, remove spacers and gently tighten 

the fastenings to take up on the now formed gasket.  

b.  Clean away any surplus sealant. 

d) 

DO NOT OVERTIGHTEN THE FASTENINGS

. Ovetightening could lead 

to  distortion  of  the  display  body  and  consequential  loss  of 
watertight/airtight integrity or break the glass or the mounting lugs. None 
of these ocurrences are covered by warranty.

 

 

 

 

 

 

Содержание 3020

Страница 1: ...ory basis Warranty is void if opened except by A T An integral tamper sensor is fitted The warranty specifically excludes physical damage lightning strike to the vessel overvoltage on supply or signal lines and use outside the normal operating environment of a yacht Trademarks A T is a registered trademark of A T Instruments Ltd B G H2000 H3000 WTP WPT2 WPT3 are product names or trademarks of Navi...

Страница 2: ...th MFD control Access and control 3020 displays by pressing MENU then navigate to System Remote Displays Once the MFD has found all displays 1 Scroll to the 3020 you want to control and press MENU to highlight the variable 2 Pressing UP or DOWN buttons will scroll through the available pages 3 Pressing the RIGHT button will let you select the data variable for that specific page Bluetooth Control ...

Страница 3: ... the Fastnet power then the 0V of this power supply should be connected common to the 0V black wire of the Fastnet bus The normal requirements for Fastnet bus apply in that two terminator resistors each of 100 Ω at either end of the network The resistance measured across green and white with no power should be close to 50 Ω Ethernet 3020 The colour codes in the cable are A T Colour Cat5e Colour Fu...

Страница 4: ...nd Net Personal dll 4 Turn on the 3020 Bluetooth 4 1 Ensure the system is powered OFF 4 2 Disconnect the Fastnet data wires either green or white from the 3020 4 3 Power ON the system 4 4 The 3020 will display PAIR within 10 seconds and display its serial number in the top line It is now ready to pair 4 5 You may set the Bluetooth to remain always ON see the Bootload instructions below To pair wit...

Страница 5: ...2 The 3020 will display LOAD and is now ready to receive the new firmware 3 Quit Exit TeraTerm 4 Run the A T Bluetooth Uploader program and click on Find unit The target 3020 will appear in the list of available displays 5 Select the target 3020 and click Connect then follow the instructions in the Uploader for opening the update file and Uploading 6 Once uploading starts the addresses on the top ...

Страница 6: ...ved surface use a bead of proprietry NON ADHESIVE sealant instead of the supplied gasket and fasten using small spacers to achieve an even gasket without squeezing all the sealant out of the gap a Once the sealant has cured remove spacers and gently tighten the fastenings to take up on the now formed gasket b Clean away any surplus sealant d DO NOT OVERTIGHTEN THE FASTENINGS Ovetightening could le...