Operation
21
5 Operation
Overview
This section covers the following topics:
•
System Start-up
•
System Shutdown
•
Hood Opening/Closing Operation
•
Setting Conveyor Clearance
Safety First
Before operating or performing maintenance on any of the equipment described in this section, please
review the important information provided in the
Safety
section.
System Start-up
WARNING!
Initial start-up of the TC V3 Conformal Curing Oven should be performed by a
trained service technician only to prevent damage to the equipment. Failure to do
so could render the factory warranty null and void.
Before starting up the Cure Module check the following:
•
Electrical network is compatible with the cure module design
•
Main circuit breaker is in the neutral position
•
Correspondence of phases (for first use)
•
Exhaust
connections
"
NOTE
When first operating the Cure Module, check the proper rotation of the oven blower,
exhaust blower, and hood blowers.
To start the Cure Module:
1. Connect the Cure Module's main power cord to the facility power source.
2. Connect the SMEMA cables to the connectors on the rear panel of the Cure Module.
3. If the Cure Module was locked out for servicing, make sure that any locks and any tags have
been removed.
4. Switch
ON
the facility power.
5. Verify that all doors are properly closed to prevent an Interlock condition. See "Interlock" in
the
Safety
section