background image

2-4

Chapter 2: Hardware Information

2.2.3 

Motherboard layout

Z10PC-D8/SAS/10G-2S

Содержание Z10PC-D8 Series

Страница 1: ...Z10PC D8 Series User Guide ...

Страница 2: ... MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL ASUS ITS DIRECTORS OFFICERS EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING DAMAGES FOR LOSS OF PROFITS LOSS OF BUSINESS LOSS OF USE OR DATA INTERRUPTION OF BUSINESS AND THE LIKE EVEN IF ASUS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR...

Страница 3: ...n 2 3 2 2 2 Screw holes 2 3 2 2 3 Motherboard layout 2 4 2 2 4 Layout contents 2 8 2 3 Central Processing Unit CPU 2 10 2 3 1 Installing the CPU 2 10 2 4 System memory 2 15 2 4 1 Overview 2 15 2 4 2 Memory Configurations 2 15 2 4 3 Installing a DIMM on a single clip DIMM socket 2 17 2 5 Expansion slots 2 18 2 5 1 Installing an expansion card 2 18 2 5 2 Configuring an expansion card 2 18 2 5 3 Inte...

Страница 4: ...sh Utility 4 3 4 1 3 BUPDATER utility 4 4 4 2 BIOS setup program 4 6 4 2 1 BIOS menu screen 4 7 4 2 2 Menu bar 4 7 4 2 3 Menu items 4 8 4 2 4 Submenu items 4 8 4 2 5 Navigation keys 4 8 4 2 6 General help 4 8 4 2 7 Configuration fields 4 8 4 2 8 Pop up window 4 8 4 2 9 Scroll bar 4 8 4 3 Main menu 4 9 4 3 1 System Date Day xx xx xxxx 4 9 4 3 2 System Time xx xx xx 4 9 4 4 Advanced menu 4 10 4 4 1 ...

Страница 5: ...38 4 5 9 Server ME Configuration 4 38 4 5 10 Runtime Error Logging Support 4 39 4 6 Server Mgmt menu 4 40 4 7 Event Logs menu 4 45 4 7 1 Change Smbios Event Log Settings 4 45 4 7 2 View Smbios Event Log 4 46 4 8 Monitor menu 4 47 4 9 Security menu 4 48 4 10 Boot menu 4 51 4 11 Tool menu 4 52 4 12 Exit menu 4 53 Chapter 5 RAID Configuration 5 1 Setting up RAID 5 2 5 1 1 RAID definitions 5 2 5 1 2 I...

Страница 6: ...Windows 5 32 5 4 1 Creating a RAID set 5 33 5 4 2 Changing a Volume Type 5 35 5 4 3 Deleting a volume 5 36 5 4 4 Preferences 5 37 5 5 LSI Corporation MPT Setup Utility 5 38 5 5 1 RAID 1 volume 5 39 5 5 2 RAID 1E 10 volume 5 45 5 5 3 RAID 0 volume 5 51 5 5 4 Managing the RAID Volumes 5 57 5 5 5 Viewing SAS topology 5 68 5 5 6 Global Properties 5 69 Chapter 6 Driver installation 6 1 RAID driver inst...

Страница 7: ...vii Contents Appendix Z10PC D8 Series block diagram A 2 Simplified EU Declaration of Conformity A 6 ASUS contact information A 7 ...

Страница 8: ...er Connect the equipment to an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help The use of shielded cables for connection of the monitor to the graphics card is required to assure compliance with FCC regulations Changes or modifications to this unit not expressly approved by the party responsible for compli...

Страница 9: ...pal waste This symbol of the crossed out wheeled bin indicates that the battery should not be placed in municipal waste Australia statement notice From 1 January 2012 updated warranties apply to all ASUS products consistent with the Australian Consumer Law For the latest product warranty details please visit https www asus com support Our goods come with guarantees that cannot be excluded under th...

Страница 10: ...our area If you are not sure about the voltage of the electrical outlet you are using contact your local power company If the power supply is broken do not try to fix it by yourself Contact a qualified service technician or your retailer Operation safety Before installing the motherboard and adding devices on it carefully read all the manuals that came with the package Before using the product mak...

Страница 11: ...s Detailed descriptions of the BIOS parameters are also provided Chapter 5 RAID Configuration This chapter provides instructions for setting up creating and configuring RAID sets using the available utilities Chapter 6 Driver Installation This chapter provides instructions for installing the necessary drivers for different system components Appendix Reference Information This appendix includes add...

Страница 12: ...information to help you complete a task Typography Bold text Indicates a menu or an item to select Italics Used to emphasize a word or a phrase Key Keys enclosed in the less than and greater than sign means that you must press the enclosed key Example Enter means that you must press the Enter or Return key Key1 Key2 Key3 If you must press two or more keys simultaneously the key names are linked wi...

Страница 13: ...y Maximum up to 512 GB Memory Type DDR4 2133 1866 1600 1333 RDIMM LR DIMM NVDIMM Refer to www asus com for the latest memory AVL update Memory Size 4 GB 8 GB 16 GB 32 GB RDIMM 32 GB 64 GB LR DIMM Expansion Slots follow SSI Location number Total PCI E Slots 3 Slot Location 1 1 x PCI E x8 X4 Gen2 Link MIO supported Slot Location 5 1 x PCI E x16 X16 Gen3 Link Slot Location 6 1 x PCI E x8 X8 Gen3 Link...

Страница 14: ...1333 RDIMM LR DIMM NVDIMM Refer to www asus com for the latest memory AVL update Memory Size 4 GB 8 GB 16 GB 32 GB RDIMM 32 GB 64 GB LR DIMM Expansion Slots follow SSI Location number Total PCI E Slots 3 Slot Location 1 1 x PCI E x8 X4 Gen2 Link MIO supported Slot Location 5 1 x PCI E x16 X16 Gen3 Link Slot Location 6 1 x PCI E x8 X8 Gen3 Link Storage SATA Controller Intel C612 10 x SATA 6 Gb s po...

Страница 15: ... 8 pin SSI 12V power connector Support both ATX and SSI Power Supply 1 Management connector Onboard socket for optional management card USB Connectors 1 x USB 3 0 pin header up to 2 devices 1 x USB 2 0 pin header up to 2 devices Fan Header 8 x 4 pin SMBus 1 Chassis Intruder 1 Front LAN LED 2 Serial Port Header 1 M 2 Connector 1 NGFF Type 2242 Capacity 16 128 GB Rear I O Connectors External USB Por...

Страница 16: ...wer connector Support both ATX and SSI Power Supply 1 Management connector Onboard socket for optional management card USB Connectors 1 x USB 3 0 pin header up to 2 devices 1 x USB 2 0 pin header up to 2 devices Fan Header 8 x 4 pin SMBus 1 Chassis Intruder 1 Front LAN LED 2 Serial Port Header 1 M 2 Connector 1 NGFF Type 2242 Capacity 16 128 GB Rear I O Connectors External USB Port 2 x USB 3 0 2 x...

Страница 17: ...1 Product Introduction This chapter describes the motherboard features and the new technologies it supports Chapter 1 Product Introduction ...

Страница 18: ...k Standard Bulk Pack I O Shield 1 1 Cables SATA 6G Cable 10 COM port Cable 1 Application CD Support DVD 1 1 piece per carton ASWM Enterprise SDVD 1 1 piece per carton Packaging Quantity 1 piece per carton 10 pieces per carton Optional items Description PIKE II 3008 LSI 8 port SAS 12G RAID card PIKE II 3108 LSI 8 port SAS 12G HW RAID card ASMB8 iKVM Remote management solution provides KVM over IP s...

Страница 19: ... image processing applications Next Generation of processor power management Intel Xeon processor E5 2600 v3 product family enhances the processor power management with the features of Energy Efficient Turbo Uncore Frequency Scaling and Per Core P state Also the Integrated Voltage Regulator enables generational performance and power improvements that the standard VR solutions cannot provide DDR4 m...

Страница 20: ... for Cloud and Storage applications It is optimized and validated to work with the latest Xeon processor E5 2600 v3 product family compared with the last generation it also reduces the TDP supports USB 3 0 with up to 10 SATA III ports thus bringing more features and benefits to the target users Serial ATA III technology The motherboard supports the Serial ATA III technology through the Serial ATA ...

Страница 21: ...mation This chapter lists the hardware setup procedures that you have to perform when installing system components It includes description of the jumpers and connectors on the motherboard Chapter 2 Hardware Information ...

Страница 22: ...object such as the power supply case before handling components to avoid damaging them due to static electricity Hold components by the edges to avoid touching the ICs on them Whenever you uninstall any component place it on a grounded antistatic pad or in the bag that came with the component Before you install or remove any component ensure that the power supply is switched off or the power cord ...

Страница 23: ...ling the motherboard ensure that you place it into the chassis in the correct orientation The edge with external ports goes to the rear part of the chassis as indicated in the image below 2 2 2 Screw holes Place nine 9 screws into the holes indicated by circles to secure the motherboard to the chassis DO NOT overtighten the screws Doing so can damage the motherboard Ensure to unplug the chassis po...

Страница 24: ...2 4 Chapter 2 Hardware Information 2 2 3 Motherboard layout Z10PC D8 SAS 10G 2S ...

Страница 25: ...2 5 ASUS Z10PC D8 Series Z10PC D8 SAS ...

Страница 26: ...2 6 Chapter 2 Hardware Information Z10PC D8 10G 2S ...

Страница 27: ...2 7 ASUS Z10PC D8 Series Z10PC D8 ...

Страница 28: ... DDR4 thermal event setting 3 pin DIMMTRIP1 2 29 6 RAID configuration utility selection 3 pin RAID_SEL1 2 30 7 PMBus 1 2 PSU select jumper 3 pin SMART_PSU1 2 30 Onboard LEDs Page 1 Standby Power LED SB_PWR1 2 22 2 Baseboard Management Controller LED BMC_LED1 2 22 3 CPU Warning LED ERR_CPU1 ERR_CPU2 2 23 4 CATT LED CATTERR_LED1 2 23 5 Q Code LEDs LED1 2 24 Slots Sockets Page 1 CPU sockets 2 10 2 DD...

Страница 29: ...an connectors 4 pin CPU_FAN1 CPU_FAN2 FRNT_FAN1 FRNT_FAN2 FRNT_FAN3 FRNT_FAN4 FRNT_FAN5 REAR_FAN1 REAR_FAN2 2 36 7 Serial port connector 10 1 pin COM1 2 36 8 Trusted Platform Module connector 20 1 pin TPM1 2 37 9 EATX power connectors 24 pin EATXPWR1 8 pin EATX12V1 8 pin EATX12V2 2 38 10 System panel connector 20 1 pin PANEL1 2 39 11 Auxiliary panel connector 20 2 pin AUX_PANEL1 2 40 12 Hard disk ...

Страница 30: ...f you see any damage to the PnP cap socket contacts motherboard components ASUS will shoulder the cost of repair only if the damage is shipment transit related Keep the cap after installing the motherboard ASUS will process Return Merchandise Authorization RMA requests only if the motherboard comes with the cap on the LGA 2011 3 socket The product warranty does not cover damage to the socket conta...

Страница 31: ...it is released from the retention tab B then gently lift the load lever C To prevent damage to the socket pins do not remove the PnP cap unless you are installing a CPU 3 Press the right load lever with your thumb D move it to the left until it is released from then gently lift the load lever F Load lever ...

Страница 32: ...rt the load lever into the retention tab The CPU fits in only one correct orientation DO NOT force the CPU into the socket to prevent bending the CPU pins on the socket 6 Get the CPU 7 Align and position the CPU over the socket ensuring that the triangle mark on the CPU matches the triangle mark on the socket box Triangle mark 5 Hold the edge then gently lift the load plate H 8 Install the CPU int...

Страница 33: ...ver under the retention tab K The PnP cap pops out of the load plate when the right load lever is inserted into the retention tab Keep the PnP cap ASUS will process Return Merchandise Authorization RMA requests only if the motherboard comes with the PnP cap on the LGA 2011 3 socket 11 Push down the left load lever L then insert it under the retention tab M Retention tab PnP cap ...

Страница 34: ... The Thermal Interface Material is toxic and inedible DO NOT eat it If it gets into your eyes or touches your skin wash it off immediately and seek professional medical help Ensure that the Thermal Interface Material is spread in an even thin layer Some heatsinks come with pre applied Thermal Interface Material If so skip this step 12 Apply some Thermal Interface Material to the exposed area of th...

Страница 35: ...onfigurations You may install 4 GB 8 GB 16 GB and 32 GB RDIMMs or 32 GB and 64 GB LR DIMMs into the DIMM sockets using the memory configurations in this section Refer to ASUS Server AVL for the updated list of compatible DIMMs When installing DIMMs always start from slot A1 CPU1 and E1 CPU2 Always install DIMMs with the same CAS latency For optimum compatibility it is recommended that you obtain m...

Страница 36: ...onfiguration Dual CPU configuration DIMM A1 B1 C1 D1 E1 F1 G1 H1 2 DIMMs P P 4 DIMMs P P P P 8 DIMMs P P P P P P P P Single CPU configuration You can refer to the following recommended memory population for a single CPU configuration Single CPU configuration must be installed on CPU1 DIMM A1 B1 C1 D1 1 DIMM P 2 DIMMs P P 4 DIMMs P P P P ...

Страница 37: ...DIMM notch DIMM slot key 1 Press the retaining clip outward to unlock the DIMM 2 Remove the DIMM from the socket Removing a DIMM from a single clip DIMM socket To install two or more DIMMs refer to the user guide bundled with the motherboard package Refer to the user guide for qualified vendor lists of the memory modules Support the DIMM lightly with your fingers when pressing the retaining clips ...

Страница 38: ...he card to the chassis with the screw you removed earlier 6 Replace the system cover 2 5 2 Configuring an expansion card After installing the expansion card configure it by adjusting the software settings 1 Turn on the system and change the necessary BIOS settings if any See Chapter 4 for information on BIOS setup 2 Assign an IRQ to the card Refer to the table Standard Interrupt assignments in sec...

Страница 39: ...le Mouse Port 13 8 Numeric Data Processor 14 9 Primary IDE Channel 15 10 Secondary IDE Channel 2 5 3 Interrupt assignments Standard Interrupt assignments 2 5 4 PCI Express x16 slot x16 link The onboard PCIE5 slot provides one x16 Gen3 link to CPU1 This slot supports VGA cards and various server class high performance add on cards 2 5 5 PCI Express x8 slot x8 link The onboard PCIE6 slot provides on...

Страница 40: ...2 20 Chapter 2 Hardware Information No Slot location Short description 1 PCIE6 PCI E x8 X8 Gen3 Link 2 PCIE5 PCI E x16 X16 Gen3 Link 3 PCIE1 PCI E x8 X4 Gen2 Link MIO supported ...

Страница 41: ...low to install an optional ASMB8 series management board on your motherboard 3 Insert the LAN cable plug to the LAN port 3 dedicated LAN or LAN port shared LAN for server management 1 Locate the Baseboard Management Card header on the motherboard 2 Orient and press the Management Card in place ...

Страница 42: ...you install the ASUS ASMB8 2 6 Onboard LEDs 1 Standby Power LED SBPWR1 The motherboard comes with a standby power LED The green LED lights up to indicate that the system is ON in sleep mode or in soft off mode This is a reminder that you should shut down the system and unplug the power cable before removing or plugging in any motherboard component The illustration below shows the location of the o...

Страница 43: ...ng LED ERRCPU1 ERRCPU2 The CPU warning LEDs light up to indicate failure on either CPU1 CPU2 or both 4 CATT LED CATTERRLED1 The CATT LED indicates that the system has experienced a fatal or catastrophic error and cannot continue to operate ...

Страница 44: ...r 2 Hardware Information 5 Q Code LEDs LED1 The Q Code LED provides a 2 digit display that shows the status of your system Refer to the Q Code table of this user guide for more information about the 2 digit codes ...

Страница 45: ...zation A9 MRC Progress QPI initialization AA MRC Progress QPI initialization AB MRC Progress QPI initialization AC MRC Progress QPI initialization AD MRC Progress QPI initialization AE MRC Progress QPI initialization AF MRC Progress QPI initialization Complete 2F Progress Memory Init B0 MRC Progress Memory Init B1 MRC Progress Memory Init AF MRC Progress RC Reset if require B4 MRC Progress Memory ...

Страница 46: ...s Enumeration 96 Progress PCI Bus Enumeration 97 Progress Console outout connect event 98 Progress Console input connect event 99 Progress AMI Super IO start 9A Progress AMI USB Driver Init 9B Progress AMI USB Driver Init 9C Progress AMI USB Driver Init 9D Progress AMI USB Driver Init b2 Progress Legacy Option ROM Init b3 Progress Reset system b4 Progress USB hotplug b6 Progress NVRAM clean up b7 ...

Страница 47: ...ter and unplug the power cord 2 Move the jumper cap from the default pins 1 2 to pins 2 3 Keep the cap on pins 2 3 for about 5 to 10 seconds then move the cap back to pins 1 2 3 Plug the power cord and turn ON the computer 4 Hold down the Del key during the boot process and enter BIOS setup to re enter data DO NOT remove the cap on CLRTC jumper default position except when clearing the RTC RAM Rem...

Страница 48: ...umper allows you to enable or disable the onboard VGA controller Set to pins 1 2 to activate the VGA feature 3 LAN controller setting 3 pin LAN_SW1 LAN_SW2 These jumpers allow you to enable or disable the onboard LAN_SW1 or LAN_SW2 Set to pins 1 2 to activate the Gigabit LAN feature ...

Страница 49: ...setting 3 pin ME_RCVR1 This jumper allows you to force Intel Management Engine ME boot from recovery mode when ME becomes corrupted 5 DDR4 thermal event setting 3 pin DIMMTRIP1 This jumper allows you to enable or disable DDR4 DIMM thermal sensing event pin ...

Страница 50: ...over pins 1 2 to use the third party software LSI MegaRAID software RAID Configuration Utility otherwise place the jumper caps to pins 2 3 to use the Intel Rapid Storage Technology enterprise SATA Option ROM Utility 7 PMBus 1 2 PSU select jumper 3 pin SMART_PSU1 This jumper allows you to select PSU PMBus version Set to pins 1 2 for PMBus set to pins 2 3 for others Available on Z10PC D8 and Z10PC D...

Страница 51: ... you enable the ASMB8 controller Refer to the Management LAN port LED indications table for more information 5 USB 2 0 ports 1 and 2 These two 4 pin Universal Serial Bus USB ports are available for connecting USB 2 0 devices 6 Video Graphics Adapter VGA port This port is for a VGA monitor or other VGA compatible devices 7 SFP LEDs These LEDs indicates the link status and the link speed of the SFP ...

Страница 52: ...escription Status Description OFF No link OFF 10 Mbps connection ORANGE Linked ORANGE 100 Mbps connection BLINKING Data activity GREEN 1 Gbps connection Management LAN port LED indications LAN port 1 2 SPEED LED ACT LINK LED ACT LINK LED SFP LED indications SFP LED Speed LED Activity LED Activity LED Speed LED Status Description Status Description OFF No activity OFF BLINKING Data activity AMBER 1...

Страница 53: ...chipset this connector is for the Serial ATA signal cables for Serial ATA hard disk drives that allows up to 6 Gbps of data transfer rate If you installed Serial ATA hard disk drives you can create a RAID 0 RAID 1 RAID 10 or RAID 5 configuration The actual data transfer rate depends on the speed of Serial ATA hard disks installed The SSATA4 Light Gray will be automatically turned off if the M 2 co...

Страница 54: ...pply unit to read PSU information Devices communicate with an SMBus host and or other SMBus devices using the SMBus interface This connector functions only when you install the ASUS ASMB8 Power supply is required to meet SMBus specification and customized BMC FW may be needed Please contact ASUS if your need further support This connector supports type 2242 devices on both PCI E and SATA interface...

Страница 55: ...ts up to 480 Mb s connection speed 5 USB 3 0 connector 20 1 pin USB3_34 This connector allows you to connect a USB 3 0 module for additional USB 3 0 front or rear panel ports With an installed USB 3 0 module you can enjoy all the benefits of USB 3 0 including faster data transfer speeds of up to 5Gbps faster charging time for USB chargeable devices optimized power efficiency and backward compatibi...

Страница 56: ...es the ground pin of the connector DO NOT forget to connect the fan cables to the fan connectors Insufficient air flow inside the system may damage the motherboard components These are not jumpers DO NOT place jumper caps on the fan connectors All fans feature the ASUS Smart Fan technology 7 Serial port connector 10 1 pin COM1 This connector is for the serial COM port Connect the serial port modul...

Страница 57: ...ector 20 1 pin TPM1 This connector supports a Trusted Platform Module TPM system which can securely store keys digital certificates passwords and data A TPM system also helps enhance network security protects digital identities and ensures platform integrity ...

Страница 58: ...4 8 pin power plugs when using 85W or below CPU otherwise the system will not boot up DO NOT forget to connect the 24 8 8 pin power plugs when using 105W or above CPU otherwise the system will not boot up Use of a PSU with a higher power output is recommended when configuring a system with more power consuming devices The system may become unstable or may not boot up if the power is inadequate Ens...

Страница 59: ...EAKER This 4 pin connector is for the chassis mounted system warning speaker The speaker allows you to hear system beeps and warnings 4 Hard disk drive activity LED 2 pin HDLED This 2 pin connector is for the HDD Activity LED Connect the HDD Activity LED cable to this connector The HD LED lights up or flashes when data is read from or written to the HDD 5 Power button soft off button 2 pin PWRSW T...

Страница 60: ...ity LED 2 pin LAN1_LINKACTLED LAN2_LINKACTLED These connectors are for Gigabit LAN activity LEDs on the front panel 3 Locator LED 2 pin LOCATORLED1 LOCATORLED2 These connectors are for the locator LED1 and LED2 on the front panel Connect the Locator LED cables to these 2 pin connector The LEDs will light up when the Locator button is pressed 4 Locator Button Switch 2 pin LOCATORBTN These connector...

Страница 61: ...the SATA or SAS add on card causes the front panel LED to light up 13 Chassis Intrusion 2 pin INTRUSION These leads are for the intrusion detection feature for chassis with intrusion sensor or microswitch When you remove any chassis component the sensor triggers and sends a high level signal to these leads to record a chassis intrusion event The default setting is short CHASSIS and GND pin by jump...

Страница 62: ...both Serial Attached SCSI and Serial ATA Each connector supports up to four deives 15 SFP 1 2 LED connectors 5 1 pin LAN34_LED1 These connectors are for 10Gb LAN activity LEDs on the front panel Connect the LAN LED cable to the backplane for LAN activity indications Available on Z10PC D8 10G 2S and Z10PC D8 SAS 10G 2S only Available on Z10PC D8 SAS 10G 2S and Z10PC D8 SAS only ...

Страница 63: ...3 Powering Up This chapter describes the power up sequence and ways of shutting down the system Chapter 3 Powering Up ...

Страница 64: ...it has a power standby feature the monitor LED may light up or switch between orange and green after the system LED turns on The system then runs the power on self test or POST While the tests are running the BIOS beeps or additional messages appear on the screen If you do not see anything within 30 seconds from the time you turned on the power the system may have failed a power on test Check the ...

Страница 65: ...ndows Server 2012 1 Press Ctrl Alt Del 2 Click on the Power icon on the lower right side of the screen 3 Select Shut down 4 In the Shutdown Event Tracker select the Other Planned option in the selection lists Otherwise select the option that best describes why you want to shut down the computer 5 Click Continue 3 2 2 Using the dual function power switch While the system is ON press the power switc...

Страница 66: ...3 4 Chapter 3 Powering Up ...

Страница 67: ...4 BIOS Setup This chapter tells how to change the system settings through the BIOS Setup menus Detailed descriptions of the BIOS parameters are also provided Chapter 4 BIOS Setup ...

Страница 68: ...atically recover the BIOS It resets the system when the BIOS recovery finished DO NOT shut down or reset the system while recovering the BIOS Doing so would cause system boot failure The recovered BIOS may not be the latest BIOS version for this motherboard Visit the ASUS website at www asus com to download the latest BIOS file Save a copy of the original motherboard BIOS file to a bootable USB fl...

Страница 69: ... to update the BIOS without having to use a DOS based utility Before you start using this utility download the latest BIOS from the ASUS website at www asus com To update the BIOS using EZ Flash Utility 1 Insert the USB flash disk that contains the latest BIOS file into the USB port 2 Enter the BIOS setup program Go to the Tool menu then select ASUS EZ Flash Utility Press Enter ASUS Tek EzFlash Ut...

Страница 70: ...B flash disk drive 2 Copy the BUPDATER utility BUPDATER exe from the ASUS support website at https www asus com support to the bootable USB flash disk drive you created earlier 3 Boot the system in DOS mode then at the prompt type BUPDATER i filename CAP where filename is the latest or the original BIOS file on the bootable USB flash disk drive then press Enter A BUPDATER i file name CAP This func...

Страница 71: ...lity returns to the DOS prompt after the BIOS update process is completed Reboot the system from the hard disk drive The BIOS update is finished Please restart your system C Current Platform Platform Z10PC D8 Version 0020 Build date 12 04 2014 New Platform Platform Z10PC D8 Version 0022 Build date 01 01 2015 ASUS Tek EzFlash Utility Start Programming Flash DO NOT SHUTDOWN THE SYSTEM Write 75 ...

Страница 72: ...un this program Press Del during the Power On Self Test POST to enter the Setup utility otherwise POST continues with its test routines If you wish to enter Setup after POST restart the system by pressing Ctrl Alt Delete or by pressing the reset button on the system chassis You can also restart by turning the system off and then back on Do this last option only if the first two failed The Setup pr...

Страница 73: ...r changing the event log settings Monitor For displaying the system temperature power status and changing the fan settings Security For changing the security settings Boot For changing the system boot configuration Tool For configuring options for special functions Exit For selecting the exit options To select an item on the menu bar press the Right or Left arrow key on the keyboard until the desi...

Страница 74: ... change the settings 4 2 6 General help At the top right corner of the menu screen is a brief description of the selected item 4 2 7 Configuration fields These fields show the values for the menu items If an item is user configurable you can change the value of the field opposite the item You cannot select an item that is not user configurable A configurable field is enclosed in brackets and is hi...

Страница 75: ...nu screen appears The Main menu provides you an overview of the basic system information and allows you to set the system date time language and security settings 4 3 1 System Date Day xx xx xxxx Allows you to set the system date 4 3 2 System Time xx xx xx Allows you to set the system time ...

Страница 76: ...for the CPU and other system devices Take caution when changing the settings of the Advanced menu items Incorrect field values can cause the system to malfunction Optimized Performance Settings Default Allows you to select BIOS setting from a list of recommended BIOS setting to optimize the performance ...

Страница 77: ...tions Disabled Enabled Enable Hibernation Enabled Allows you to enable or disable the ability of the system to hibernate OS S4 Sleep State Configuration options Disabled Enabled This option may be not be effective with some OS 4 4 2 Smart Settings SMART Self Test Enabled Allows you to run SMART Self Test on all HDDs during POST Configuration options Disabled Enabled ...

Страница 78: ... IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port 2 Configuration Allows you to set the parameters of Serial Port 2 Serial Port Enabled Allows you to enable or disable Serial Port Configuration options Disabled Enabled Change Settings Auto Allows you to choose the setting for Super IO device Configuratio...

Страница 79: ...Enable Enabled Allows you to enable or disable the Intel LAN Configuration options Disabled Enabled Intel LAN ROM Type PXE Allows you to select the Intel LAN ROM type Configuration options Disabled PXE iSCSI 4 4 4 Onboard LAN I210 Configuration ...

Страница 80: ...ettings specify how the host computer and the remote computer which the user is using will exchange data Both computers should have the same or compatible settings The following item appears only when you set Console Redirection to Enabled COM1 COM2 Console Redirection Enabled Allows you to enable or disable the console redirection feature Configuration options Disabled Enabled ...

Страница 81: ...t indicates the beginning The standard setting is 1 stop bit Communication with slow devices may require more than 1 stop bit Configuration options 1 2 Flow Control Hardware RTS CTS Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re st...

Страница 82: ...gement of a Windows Server OS through a serial port Configuration options COM1 COM2 Terminal Type VT UTF8 Microsoft Windows Emergency Management Services EMS allow for remote management of a Windows Server OS through a serial port Configuration options VT100 VT100 VT UTF8 ANSI Bits per second 115200 Microsoft Windows Emergency Management Services EMS allow for remote management of a Windows Server...

Страница 83: ...te was before the AC power loss Configuration options Power Off Power On Last State Power On By PCIE Disabled Disabled Disables the PCIE devices to generate a wake event Enabled Enables the PCIE devices to generate a wake event Power On By Ring Disabled Disabled Disables the PCIE devices to generate a wake event Enabled Enables the PCIE devices to generate a wake event Power On By RTC Disabled Dis...

Страница 84: ...oding Configuration options Disabled Enabled SR IOV Support Disabled This option enables or disables SIngle Root IO Virtualization Support if the system has SR IOV capable PCIe devices Configuration options Disabled Enabled 4 4 7 Advanced Power Management Configuration Allows you to configure the advanced power management features of the system Power Boost Normal Allows you to increase extra power...

Страница 85: ... Support Enabled Enables or disables the Ipv4 PXE Boot Support If disabled Ipv4 PXE boot option will not be created Configuration options Disabled Enabled Ipv6 PXE Support Enabled Enables or disables the Ipv6 PXE Boot Support If disabled Ipv6 PXE boot option will not be created Configuration options Disabled Enabled PXE boot wait time 0 Wait time to press ESC key to abort the PXE boot Media detect...

Страница 86: ...isplay mode for option ROM Configuration options Force BIOS Keep Current Boot Option filter Legacy only This option allows you to control the Legacy UEFI ROMs priority onfiguration options UEFI and Legacy Legacy only UEFI only Network Storage Video Legacy This option allows you to control the execution of UEFI and Legacy PXE Storage Video OpROM Configuration options UEFI Legacy Other PCI devices L...

Страница 87: ...21 ASUS Z10PC D8 Series 4 4 11 Trusted Computing Configuration Security Device Support Disabled Allows you to enable or disable the BIOS support for security device Configuration options Disabled Enabled ...

Страница 88: ...e should be claimed by XHCI driver Configuration options Disabled Enabled EHCI Hand off Disabled This is a workaround for 0Ses without EHCI hand off support The EHCI ownership change should be claimed by EHCI driver Configuration options Disabled Enabled USB Mass Storage Driver Support Enabled Allows you to enable or disable the USB Mass Storage drvier support Configuration options Disabled Enable...

Страница 89: ... up delay Auto This is the maximum time the device will take before it properly reports itself to the host controller Configuration options Auto Manual Mass Storage Devices JetFlashTranscend 4GB 8 07 Auto Allows you to select the mass storage device emulation type Configuration options Auto Floppy Forced FDD Hard Disk CD ROM USB Ports Per Port Disable Control USB3_1 6 USB_7 8 Enabled Allows you to...

Страница 90: ...4 24 Chapter 4 BIOS Setup 4 5 IntelRCSetup menu The IntelRCSetup menu items allow you to change the processor and chipset settings ...

Страница 91: ...d Configuration options Disabled Enabled Execute Disable Bit Enabled XD can prevent certain classes of malicious buffer overflow attacks when combined with a supporting OS Windows Server 2003 SP1 Windows XP SP2 SuSE Linux 9 2 Redhat Enterprise 3 Update 3 Configuration options Disabled Enabled Enable Intel TXT Support Disabled Forces the XD feature log to always return 0 when disabled Configuration...

Страница 92: ...L1 line based upon sequential load history Configuration options Disabled Enabled DCU Mode 32K 8Way Without ECC Configuration options 32K 8Way Without ECC 16K 4Way With ECC Direct Cache Access DCA Auto This Item allows you to enable or disable Direct Cache Access Configuration options Auto Disabled Enabled DCA Prefetch Delay 32 This Item allows you to set the time for the DCA Prefetch delay Help C...

Страница 93: ... Disabled Enabled CPU Advanced PM Turning This item allows you to set additional CPU Power Management settings Energy Perf BIAS Energy Performance Tuning Disabled Allows your system to select from BIOS or operating system to choose enable energy performance bias tuning Configuration options Disabled Enabled Energy Performance Bias setting Balanced Performance Allows you to set the Energy Performan...

Страница 94: ...ad Configuration Balanced Optimization for the workload characterization Configuration options Balanced I O sensitive Averaging Time Window 23 This is used to control the effective window of the average for CO and PO time PO TotalTimeThreshold Low 35 The HW switching mechanism disables the performance setting 0 when the total PO time is less than this threshold PO TotalTimeThreshold High 58 The HW...

Страница 95: ...mode Configuration options Slow Fast Link Frequency Select Auto This item allows you for selecting the QPI link frequency Configuration options Auto 6 4 GT s 8 0 GT s 9 6 GT s Link L0p L1 Enable Enable This item allows you to disable or enable Link L0p or Link L1 Configuration options Disable Enable Snoop Mode Early Snoop This item allows you to select the snoop mode Configuration options Not Supp...

Страница 96: ...e halt on mem Training Error Configuration options Disabled Enabled ECC Support Auto Allows you to enable or disable the ECC support Configuration options Auto Disabled Enabled Enhanced Log Parsing Disabled Allows you to enable or disable the enhanced log parsing Configuration options Auto Disabled Enabled Dram Maintenance Test Direction UP Direction Allows you to select the dram maintenance test ...

Страница 97: ...nabled Dram Maintenance Refresh enabling Enabled Allows you to enable or disable dram maintenance refresh Configuration options Disabled Enabled Data Scrambling Auto Allows you to enable disable data scrambling Configuration options Auto Disabled Enabled Enable ADR Disabled Allows you to set the detecting and enabling of ADR Configuration options Disabled Enabled C A Parity Enable Auto Allows you ...

Страница 98: ...other related Memory Power Savings features Configuration options Auto Disabled APD On User Defined Reserved Reserved Memory Power Savings Advanced Options CK in SR Auto Configuration options Auto Driven Tri State Pulled Low Pulled High MDLL Off Auto Allows you to shutdown MDLL during SR when enabled Configuration options Auto Disabled Enabled MEMHOT Throttling Mode Input only Allows you to shutdo...

Страница 99: ...iguration Setup RAS Mode Disabled Allows you to enable or disable RAS Modes Configuration options Disabled Mirror Lockstep Mode Memory Rank Sparing Disabled Allows you to enable or disable Memory Rank Sparing Configuration options Disabled Enabled Correctable Error Threshold 32767 Allows you to set the Correctable Error Threshold used for sparing tagging and leaky bucket The range is from 1 to 327...

Страница 100: ...led Allows you to enable or disable the PCIE1 PCIE5 PCIE6 Option ROM Configuration options Disabled Enabled Intel VT for Directed I O VT d Intel VT for Directed I O VT d Enabled Allows you to enable or disable the Intel Virtualization Technology for Directed I O Configuration options Disabled Enabled PCI Express Global Options TX EQ WA Enabled Use special table for TX_EQ and vendor specific cards ...

Страница 101: ...Only This option enables or disables the ASPM support for all downstream devices Configuration options Disabled L1 Only DeepSx Power Policies Disabled Allows you to configure the DeepSx Mode configuration Configuration options Disabled Enabled in S5 Enabled in S4 S5 PCI Express Configuration ...

Страница 102: ...ntroller Enabled Allows you to enable or disable the sSATA Controller Configuration options Disabled Enabled Configure sSATA as AHCI Allows you to identify the SATA port is connected to Solid State Drive or Hard Disk Drive Configuration options IDE AHCI RAID Support Aggressive Link Power Management Enabled Allows you to enable or disable the Suport Aggressive Link Power SALP Management Configurati...

Страница 103: ...SATA port is connected to Solid State Drive or Hard Disk Drive Configuration options IDE AHCI RAID Support Aggressive Link Power Management Enabled Allows you to enable or disable the Suport Aggressive Link Power SALP Management Configuration options Disabled Enabled SATA Port 1 6 Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Enabled Allows you to enable or disable the SATA port Configuration options ...

Страница 104: ...sabled Enabled Alert Enable Lock Disabled Allows you to lock all Alert Enable settings Configuration options Disabled Enabled 4 5 8 Miscellaneous Configuration Active Video Offboard Device Allows you to select the video type Configuration options Onboard Device Offboard Device 4 5 9 Server ME Configuration Displays the Server ME Technology parameters on your system ...

Страница 105: ...e S W error injection support Configuration options Disabled Enabled Whea Settings Whea Support Enabled This item allows you to enable or disable the WHEA support Configuration options Disabled Enabled Memory Error Enabling Memory corrected Error enabling Disabled This item allows you to enable or disable memory corrected error Configuration options Disabled Enabled ...

Страница 106: ...ure the length fo the OS Boot Watchdog Timer Configuration options 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Reset This item allows you to configure the how the system should respond if the OS Boot Watch Timer expires Configuration options Do Nothing Reset Power Down Power Cycle Serial Mux Disabled This item allows you to enable or disable Serial Mux configuration Configuratio...

Страница 107: ...All values changed here do not take effect until computer is restarted Erase SEL No Allows you to choose options for erasing SEL Configuration options No Yes On next reset Yes On every reset When SEL is Full Do Nothing Allows you to choose options for reactions to a full SEL Configuration options Do Nothing Erase Immediately Log EFI Status Codes Error code Disable the logging of EFI Status Codes o...

Страница 108: ...M_LAN1 Shared LAN Previous State This item allows you to configure LAN channel parameters statistically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Configuration options Previous State Static DynamicBmcDhcp DynamicBmcNonDhcp View System Event Log This item allows you to view the system event log records ...

Страница 109: ... Disable Enable IPv6 Display Letter Case Upper Case Displays the uppercase or lowercase letters of the alphabet Configuration options Lower Case Upper Case IPv6 BMC DM_LAN1 IPv6 BMC LAN IP Address source Previous State Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Configuration options Previous State Static Dynamic Obtained by BMC running DHCP The following it...

Страница 110: ...onfigure LAN channel parameters statically or dynamically by BIOS or BMC Configuration options Previous State Static Dynamic Obtained by BMC running DHCP The following items appear only when you set IP BMC Lan IP Address Source to Static IPv6 BMC LAN IP Address Allows you to input IPv6 BMC Lan IP address IPv6 BMC LAN IP Prefix Length Allows you to input IPv6 BMC Lan IP Prefix Length IPv6 BMC LAN D...

Страница 111: ...n Enabling Disabling Options Smbios Event Log Enabled Change this to enable or disable all features of Smbios Event Logging during boot Configuration options Disabled Enabled Erasing Settings Erase Event Log No Choose options for erasing Smbios Event Log Erasing is done prior to any logging activation during reset Configuration options No Yes Next reset Yes Every reset All values changed here do n...

Страница 112: ...s Event Log Configuration options Do Nothing Erase Immediately Smbios Event Log Standard Settings Log System Boot Event Disabled Allows you to choose options to enable disable logging of System boot event Configuration options Enabled Disabled 4 7 2 View Smbios Event Log Press Enter to view all smbios event logs ...

Страница 113: ...ear fan in rotations per minute RPM If the fan is not connected to the motherboard the field shows N A VCCIO VCORE1 2 VDDQ_AB VDDQ_CD VDDQ_EF VDDQ_GH 5VSB 5V 12V 3 3V VBAT 3 3VSB The onboard hardware monitor automatically detects the voltage output through the onboard voltage regulators CPU_FAN1 2 FRNT_FAN1 4 REAR_FAN1 2 mode Generic Speed Allows you to configure the ASUS Smart Fan feature that sm...

Страница 114: ...rom the Create New Password box key in a password then press Enter 3 Confirm the password when prompted To change an administrator password 1 Select the Administrator Password item and press Enter 2 From the Enter Current Password box key in the current password then press Enter 3 From the Create New Password box key in a new password then press Enter 4 Confirm the password when prompted To clear ...

Страница 115: ...assword box key in a new password then press Enter 4 Confirm the password when prompted To clear a user password 1 Select the Clear User Password item and press Enter 2 Select Yes from the Warning message window then press Enter Secure Boot Menu This item allows you to customize the Secure Boot settings Secure Boot Disabled Secure Boot can be enabled if the system is running in User mode with enro...

Страница 116: ... This item will ask you if you want to Install Factory Default secure keys Select Yes if you want to load the default secure keys otherwise select No Save All Secure Boot Variables This item will ask you if you want to save all secure boot variables Select Yes if you want to save all secure boot variables otherwise select No Platform Key Key Exchange Key Authorized Signatures Authorized TimeStamps...

Страница 117: ...en Disabled POST Report 5 sec Allows you to set the desired POST Report waiting time from 1 to 10 seconds Configuration options 1 sec 10 sec Until Press ESC Chassis Intrusion Warning Allows you to set an action when chassis intrusion has occured Configuration options Warning Halt Boot Option Priorities These items specify the boot device priority sequence from the available devices The number of d...

Страница 118: ...33 Disabled Hard Drive BBS Priorities Network Device BBS Priorities These items appear only when you connect SATA ODD or hard drive to the SATA ports and allow you to set the booting order of the SATA devices 4 11 Tool menu The Tool menu items allow you to configure options for special functions Select an item then press Enter to display the submenu ASUS EZ Flash Allows you to run ASUS EZ Flash BI...

Страница 119: ...to the BIOS items Save Changes Exit Exit System setup after saving the changes Discard Changes Exit Exit System setup without saving any changes Save Changes Reset Reset the system setup after saving the changes Discard Changes Reset Reset system setup without saving any changes Save Options Save Changes Save changes done so far to any of the setup options Discard Changes Discard changes done so f...

Страница 120: ... the User Defaults to all the setup options Boot Override These items displays the available devices The device items that appears on the screen depends on the number of devices installed in the system Click an item to start booting from the selected device Launch EFI Shell from filesystem device Attempts to launch EFI Shell application shellx64 efi from one of the available filesystem devices ...

Страница 121: ...5 RAID Configuration This chapter provides instructions for setting up creating and configuring RAID sets using the available utilities Chapter 5 RAID Configuration ...

Страница 122: ...es or use an existing drive and a new drive for this setup The new drive must be of the same size or larger than the existing drive RAID 1E Enhanced RAID 1 has a striped layout with each stripe unit having a secondary or alternate copy stored on a different disk You can use three or more hard disk drives for this configuration RAID 10 is data striping and data mirroring combined without parity red...

Страница 123: ...each RAID controller For example use the LSI MegaRAID Software Configuration Utility or the Intel Rapid Storage Technology if you installed Serial ATA hard disk drives on the Serial ATA connectors supported by the Intel C612 chipset Refer to the succeeding section for details on how to use the RAID configuration utility 5 1 2 Installing hard disk drives The motherboard supports Serial ATA for RAID...

Страница 124: ...ng RAID set s Press Ctrl M to enter the utility The LSI MegaRAID software RAID configuration utility automatically configures to RAID 1 when the SATA to RAID Mode is enabled The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference When you create RAID sets with the LSI MegaRAID software RAID conf...

Страница 125: ...n command This menu also allows you to view add or clear RAID configurations or select the boot drive Initialize Allows you to initialize the virtual drives of a created RAID set Objects Allows you to initialize virtual drives or change the virtual drive parameters Rebuild Allows you to rebuild failed drives Check Consistency Allows you to check the data consistency of the virtual drives of a crea...

Страница 126: ...ing a RAID 1 set You need at least four identical hard disk drives when creating a RAID 10 set SPACE Sel ENTER EndArray F10 Configure F2 Drive Info F3 Virtual Drives F4 HSP LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Port 2 DISK 74 74GB HDS728080PLA380 05 01C05 Configure Initialize Objects Rebuild Check Consistency Management Menu Easy Configuration ARR...

Страница 127: ...AY SELECTION MENU ONLIN A00 00 ONLIN A00 01 READY READY 0 1 2 3 PORT Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 1 148 580GB 2 64KB ONLINE RAID 1 Units MB Size 152146MB DWC OFF RA On Accept SPAN NO Virtual Drive 0 Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523...

Страница 128: ... Objects Rebuild Check Consistency Management Menu Easy Configuration ARRAY SELECTION MENU ONLIN A00 00 ONLIN A00 01 READY READY 0 1 2 3 PORT Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 1 148 580GB 2 64KB ONLINE MB GB TB Select Units For VD Size RAID 1 Units MB Size 152146MB DWC OFF RA On Accept SPAN NO Virtual Drive 0 Use Cursor Keys To Navigate Between Items And Press Enter ...

Страница 129: ...eck Consistency Management Menu Easy Configuration ARRAY SELECTION MENU ONLIN A00 00 ONLIN A00 01 READY READY 0 1 2 3 PORT Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 1 148 580GB 2 64KB ONLINE RAID 1 Units MB Size 152146MB DWC OFF RA On Accept SPAN NO Virtual Drive 0 Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration U...

Страница 130: ...ursor Keys To Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Clear Existing Configuration And Start A New Configuration Configure Initialize Objects Rebuild Check Consistency Management Menu Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive Configurat...

Страница 131: ... the screen 3 Follow step 3 to 12 of section 5 2 1 Creating a RAID set Using Easy Configuration to add a new RAID set Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R View Add to The Existing Configuration Configure Initialize Objects Rebuild Check Consistency Management Menu Easy ...

Страница 132: ...e Use the arrow keys to select the virtual drive from the Virtual Drive selection and then press Space Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Initialize VD s Configure Initialize Objects Rebuild Check Consistency Management Menu SPACE De Select F10 Initialize LSI Software...

Страница 133: ...ta On Selected VD s Configure Initialize Objects Rebuild Check Consistency Management Menu Easy Configuration ARRAY SELECTION MENU Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 1 148 580GB 2 64KB ONLINE Virtual Drive 0 Virtual Drives Yes No Initialize SPACE De Select F10 Initialize LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Configure...

Страница 134: ...Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Change VD Parameters Configure Initialize Objects Rebuild Check Consistency Management Menu Adapter Virtual Drive Physical Drive Objects Press ENTER To Select A VD Del To Delete A VD LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Select VD Con...

Страница 135: ... A 10 09231523R Initialize VD Configure Initialize Objects Rebuild Check Consistency Management Menu Adapter Virtual Drive Physical Drive Objects Virtual Drive 0 Virtual Drive 1 Initialize Check Consistency View Update Parameters Virtual Drive 0 Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A ...

Страница 136: ...Space Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Rebuild VD s Configure Initialize Objects Rebuild Check Consistency Management Menu SPACE De Select F10 Start Rebuild F2 Drive Information F3 View Virtual Drives LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS...

Страница 137: ...Rebuild F2 Drive Information F3 View Virtual Drives LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Port 1 DISK 77247MB HDS72808PLA380 PF20A60A Configure Initialize Objects Rebuild Check Consistency Management Menu REBUILD PHYSICAL DRIVES SELECTION MENU ONLIN A00 00 FAIL A00 01 0 1 PORT Rebuilding of Drive Will Take A Few Minutes Start Rebuilding Drive Y N ...

Страница 138: ...2 The screen displays the available RAID set s and prompts you to select the virtual drive to check Press Space to select the virtual drive from the Virtual Drive sub menu and then press F10 Use Cursor Keys to Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R CC of VD s Configure Initialize Objects Re...

Страница 139: ... Initialize LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Select VD s Configure Initialize Objects Rebuild Check Consistency Management Menu Easy Configuration ARRAY SELECTION MENU Virtual Drive s Configured LD RAID Size Stripes StripSz Status 0 10 154494MB 2 64KB ONLINE Virtual Drive 0 Virtual Drives Yes No Consistency Check SPACE De Select F10 Initializ...

Страница 140: ...ects and then select Virtual Drive from the sub menu 2 Use the arrow keys to select the virtual drive you want to check and then press Enter 3 Select Check Consistency from the pop up menu and then press Enter 4 When prompted use the arrow keys to select Yes from the dialog box to check the drive 5 When checking is complete press any key to continue ...

Страница 141: ... Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Clear Existing Configuration Configure Initialize Objects Rebuild Check Consistency Management Menu Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive Configuration Menu Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17...

Страница 142: ...o Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Select A Boot VD Configure Initialize Objects Rebuild Check Consistency Management Menu Easy Configuration New Configuration View Add Configuration Clear Configuration Select Boot Drive Configuration Menu Use Cursor Keys To Navigate Between Items And...

Страница 143: ...ct Disk WC and then press Enter to turn on the option Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option LSI Software RAID Configuration Utility Ver C 05 Sep 17 2010 BIOS Version A 10 09231523R Disk Write Cache Off Write Through or On Write Back Configure Initialize Objects Rebuild Check Consistency Management Menu Adapter Virtual Drive Physical Drive Objects Rebuild Rat...

Страница 144: ...ss Ctrl I to display the utility main menu Before you proceed ensure that you have installed the Serial ATA hard disk drives have set the correct jumper settings of the motherboard and have set the correct SATA mode in the BIOS setup You can refer to the Installing hard disk drives Setting Jumpers and Setting the RAID items in BIOS for more information ESC Exit ENTER Select Menu Select Intel R Rap...

Страница 145: ...you are done ESC Previous Menu ENTER Select Change Intel R Rapid Storage Technology enterprise SATA Option ROM 3 6 0 1023 Copyright C 2003 12 Intel Corporation All Rights Reserved CREATE VOLUME MENU HELP Name RAID Level Disks Strip Size Capacity Syne Create Volume Enter a unique volume name that has no special characters and is 16 characters or less Volume0 RAID0 Strips Select Disks 128KB 0 0 GB N...

Страница 146: ...igher stripe size for multimedia computer systems used mainly for audio and video editing 7 In the Capacity field item key in the RAID volume capacity that you want to use and press Enter The default value field indicates the maximum allowed capacity 8 Press Enter to start creating the RAID volume 9 From the following warning message press Y to create the RAID volume and return to the main menu or...

Страница 147: ...rn to the utility main menu or press N to return to the DELETE VOLUME menu ESC Previous Menu Select Intel R Rapid Storage Technology enterprise SATA Option ROM 3 6 0 1023 Copyright C 2003 12 Intel Corporation All Rights Reserved DELETE VOLUME MENU HELP Deleting a volume will reset the disks to non RAID WARNING ALL DISK DATA WILL BE DELETED This does not apply to Recovery volumes DEL Delete Volume ...

Страница 148: ...pace A small triangle before the Port number marks the selected drive Press Enter when you are done 3 Press Y in the confirmation window to reset the drive s or press N to return to the utility main menu Port Drive Model Serial Size Status 0 ST3300656SS HWAS0000991753TR 279 3GB Member Disk 1 ST3300656SS 37VN00009846RAJ1 279 3GB Member Disk Select the disks that should be reset Resetting RAID disk ...

Страница 149: ... Hard Disk available the utility will prompt you to rebuild the RAID Press the up down arrow keys to select the destination disk then Press Enter to start the rebuilding process or press ESC to exit 5 3 4 Exiting the Intel Rapid Storage Technology enterprise SATA SSATA Option ROM utility To exit the utility 1 From the utility main menu select 4 Exit then press Enter 2 Press Y to exit or press N to...

Страница 150: ...ded during POST You may replace the disk drive and rebuild the RAID array To rebuild the RAID with a new hard disk 1 Remove the failed SATA hard disk and install a new SATA hard disk of the same specification into the same SATA Port Select a destination disk with the same size as the original hard disk 2 Reboot the system then follow the steps in section Rebuilding the RAID with other non RAID dis...

Страница 151: ...rray in the BIOS Set at least one of the arrays bootable to boot from the hard disk 1 Reboot the system and press Del to enter the BIOS setup utility during POST 2 Go to the Boot menu and select the boot option priority 3 Use up down arrow keys to select the boot priority and press Enter See the Boot menu section of Chapter 4 for more details 4 From the Exit menu select Save Changes Exit then pres...

Страница 152: ...on the system and go to the windows desktop 2 Click the Intel Rapid Storage Technology enterprise icon to display the main menu Your storage system is configured for data protection increased performance and optimal data storage capacity You can create additional volumes to further optimize your storage system To enter the Intel Rapid Storage Technology enterprise utility under Windows operating s...

Страница 153: ...lume type 2 Click Next 3 Enter a name for the RAID set then select the array disks 4 Select Volume Size tab you can drag the bar to decide the volume size 5 Click Next If you do not want to keep the data on one of the selected disks select NO when prompted If you want to Enable volume write back cache or Initialize volume click Advanced ...

Страница 154: ... number and size of the disks You can continue using other applications during this time 7 Wait until the process is completed then click OK when prompted You still need to partition your new volume using Windows Disk Management before adding any data The RAID set is displayed in the Volumes list and you can change the settings in Volume Properties ...

Страница 155: ...pe size for server systems and a higher stripe size for multimedia computer systems used mainly for audio and video editing 3 You can change the Name Select the new volume type and Select additional disks to include in the new volume if needed 4 Select the Data stripe size for the RAID array for RAID 0 10 and 5 only and click OK The available stripe size values range from 4 KB to 128 KB The follow...

Страница 156: ...that you back up all your important data from your hard drives To delete a volume 1 From the utility main menu select the volume exp Volume_0000 in Volumes field you want to delete 3 Click Yes to delete the volume and return to the utility main menu or click No to return to the main menu 2 Select Delete volume in Volume Properties field The following screen appears ...

Страница 157: ...rences Allow you to set to show the notification area icon and show system information warning or errors here E Mail Preferences Allow you to set to sent e mail of the following events Storage system information Storage system warnings Storage system errors ...

Страница 158: ...l ATA and SAS disk drives in one volume The RAID setup screens shown in this section are for reference only and may not exactly match the items on your screen due to the controller version difference The adapter name shown on the setup screens differs according to the installed SAS RAID card MPTFW and MPTBIOS version of the SAS RAID card Take note of the MPTFW and MPTBIOS version of your SAS RAID ...

Страница 159: ...ored volumes with two disks The RAID 1 feature supports hot swap capability so when a disk in an RAID 1 volume fails you can easily restore the volume and the swapped disk is automatically re mirrored To create a RAID 1 volume 1 Turn on the system after installing all SAS hard disk drives 2 During POST press Ctrl C to enter the SAS configuration utility To avoid data loss do not turn off the syste...

Страница 160: ... Configuration 4 From the Adapter Properties screen use the arrow keys to select RAID Properties then press Enter 5 From the Select New Volume Type screen use the arrow keys to select Create RAID 1 Volume then press Enter ...

Страница 161: ...ult the RAID Disk field shows No before volume creation This field is grayed out under the following conditions The disk does not meet the minimum requirements for use in a RAID volume The disk is not large enough to mirror existing data on the primary drive The disk is already part of another volume 7 If a selected disk contains no files or data the utility adds the disk to the array ...

Страница 162: ...s files or data the following message appears on the screen To proceed perform either of the following Click any key to continue Press M to keep existing data on the first disk If you choose this option data on the first disk will be mirrored on the second disk that you will add to the volume later Ensure the data you want to mirror is on the first disk Press D to overwrite any data and create the...

Страница 163: ...5 43 ASUS Z10PC D8 Series 11 Wait while utility creates the volume 12 When done the utility displays the Adapter Properties screen From this screen click RAID Properties ...

Страница 164: ...5 44 Chapter 5 RAID Configuration 13 From the Select New Volume Type screen click View Existing Volume 14 From the View Volume screen the utility displays the new volume you created ...

Страница 165: ...e use even numbers of hard disk drives to create a RAID 10 volume 3 From the Adapter List screen select an item and press Enter The number of items displayed depends on the controller To create a RAID 1E 10 volume 1 Turn on the system after installing all SAS hard disk drives 2 During POST press Ctrl C to enter the SAS configuration utility To avoid data loss do not turn off the system when rebuil...

Страница 166: ...onfiguration 4 From the Adapter Properties screen use the arrow keys to select RAID Properties then press Enter 5 From the Select New Volume Type screen use the arrow keys to select Create RAID 1E 10 Volume then press Enter ...

Страница 167: ...ault the RAID Disk field shows No before volume creation This field is grayed out under the following conditions The disk does not meet the minimum requirements for use in a RAID volume The disk is not large enough to mirror existing data on the primary drive The disk is already part of another volume 7 If a selected disk contains no files or data the utility adds the disk to the array ...

Страница 168: ...k contains files or data the following message appears on the screen To proceed do either of the following Click any key to continue Press M to keep existing data on the first disk If you choose this option data on the first disk will be mirrored on the second disk that you will add to the volume later Ensure the data you want to mirror is on the first disk Press D to overwrite any data and create...

Страница 169: ...5 49 ASUS Z10PC D8 Series 11 Wait while utility creates the volume 12 When done the utility displays the Adapter Properties screen To check the new volume you created click RAID Properties ...

Страница 170: ...5 50 Chapter 5 RAID Configuration 13 From the Select New Volume Type screen click View Existing Volume 14 From the View Volume screen the utility displays new volume you created ...

Страница 171: ...r RAID 1E 10 volume 3 From the Adapter List screen select an item and press Enter The number of items displayed depends on the controller To create a RAID 0 volume 1 Turn on the system after installing all SAS hard disk drives 2 During POST press Ctrl C to enter the SAS configuration utility To avoid data loss do not turn off the system when rebuilding ...

Страница 172: ... Configuration 4 From the Adapter Properties screen use the arrow keys to select RAID Properties then press Enter 5 From the Select New Volume Type screen use the arrow keys to select Create RAID 0 Volume then press Enter ...

Страница 173: ...ault the RAID Disk field shows No before volume creation This field is grayed out under the following conditions The disk does not meet the minimum requirements for use in a RAID volume The disk is not large enough to mirror existing data on the primary drive The disk is already part of another volume 7 If a selected disk contains no files or data the utility adds the disk to the array ...

Страница 174: ...k contains files or data the following message appears on the screen To proceed do either of the following Click any key to continue Press M to keep existing data on the first disk If you choose this option data on the first disk will be mirrored on the second disk that you will add to the volume later Ensure the data you want to mirror is on the first disk Press D to overwrite any data and create...

Страница 175: ...5 55 ASUS Z10PC D8 Series 11 Wait while utility creates the volume 12 When done the utility displays the Adapter Properties screen To check the new volume you created click RAID Properties ...

Страница 176: ...5 56 Chapter 5 RAID Configuration 13 From the Select New Volume Type screen click View Existing Volume 14 From the View Volume screen the utility displays new volume you created ...

Страница 177: ...rform volume consistency check activate the volume delete volume and expand the volume capacity using the utility Viewing volume properties To view volume properties 1 From the Adapter Properties screen use the arrow keys to select RAID Properties then press Enter 2 From the Select New Volume Type screen click View Existing Volume ...

Страница 178: ...From the View Volume screen you can view properties of the RAID volume s you created If you have configured a hot spare for a volume it will also be listed If you created more than one volume you can view the next volume by pressing Alt N ...

Страница 179: ...ection when adding a hot spare disk on an existing volume If a disk on an RAID 1 1E 10 volume fails the utility automatically rebuilds the failed disk data on the hot spare When the failed disk is replaced the utility assigns the replacement as the new hot spare To create a hot spare 1 From the Adapter Properties screen use the arrow keys to select RAID Properties then press Enter 2 From the Selec...

Страница 180: ...5 60 Chapter 5 RAID Configuration 3 From the View Volume screen click Manage Volume 4 From the Manage Volume screen select Manage Hot Spares then press Enter ...

Страница 181: ... use the arrow keys to select the disk you want to configure as hot spare Move the cursor to the Hot Spr column then press or Space 7 Press C to commit the changes 9 Wait for the utility to finish 8 Select Save changes then exit this menu to create the hot spare ...

Страница 182: ...nning a consistency check To run a consistency check on the RAID volume 1 From the Adapter Properties screen use the arrow keys to select RAID Properties then press Enter 2 From the Select New Volume Type screen click View Existing Volume ...

Страница 183: ...63 ASUS Z10PC D8 Series 4 From the Manage Volume screen select Consistency Check then press Enter 3 From the View Volume screen click Manage Volume ...

Страница 184: ...ith the volume consistency check To check the status go to the Manage Volume screen and look at the information displayed on the Volume Status field If you see a screen similar to the one shown below press Enter to proceed with the volume consistency check ...

Страница 185: ...ler computer or moved to another the volume is considered inactive To add the volume back to the system you need to reactivate the volume To activate the volume 1 Go to the Manage Volume screen select Activate Volume then press Enter 2 Press Enter to activate the inactive RAID volume ...

Страница 186: ...p important data before deleting a volume The hot spare disk that you configured for a volume is also be deleted when you delete the volume If you delete a RAID 1 volume the data is preserved on the primary disk To delete a volume 1 Go to the Manage Volume screen select Delete Volume then press Enter 2 Press Y to delete ...

Страница 187: ...lume The capacity of the new hard disk drives should be 50GB larger than the existing one This function is available only when the RAID 1 volume is optimal To expand the capacity of the currently displayed RAID volume 1 Go to the Manage Volume screen select Online Capacity Expansion then press Enter 2 Press Enter to proceed with the online capacity expansion ...

Страница 188: ...SAS topology To view the SAS Topology 1 Go to the Adapter Properties screen select SAS Topology then press Enter 2 Press Alt D to display device properties or Alt M to display more keys Information about the volume and its member disks are displayed ...

Страница 189: ... the Global Properties menu Go to the Adapter List screen then press Alt N From Global Properties menu you can change the following settings A Pause When Boot Alert Displayed Sets whether to pause or not when the boot alert displays Configuration options Yes No ...

Страница 190: ...ets the disk information display mode Configuration options Display adapters installed devices Display adapters only Display adapters and all devices Display minimal information C Support Interrupt Configuration options Hook interrupt the Default Bypass interrupt hook ...

Страница 191: ...5 71 ASUS Z10PC D8 Series D Restore Defaults This option allows you to discard the selections you made and restore the system defaults ...

Страница 192: ...72 Chapter 5 RAID Configuration ...

Страница 193: ... Driver Installation This chapter provides the instructions for installing the necessary drivers for different system components in both Linux and Windows Operating Systems Chapter 6 Driver installation ...

Страница 194: ...Otherwise the system will not boot from the connected SATA ODD To create a RAID driver disk in Windows environment 1 Start Windows 2 Place the motherboard support DVD into the optical drive 3 Go to the Make disk menu and then select the type of RAID driver disk you want to create 4 Insert a floppy disk into the USB floppy disk drive 5 Follow succeeding screen instructions to complete the process W...

Страница 195: ...o install the RAID controller driver when installing Windows Server 2008 R2 OS 1 Boot the computer using the Windows Server 2008 R2 OS installation disc Follow the screen instructions to start installing Windows Server 2008 R2 2 When prompted to choose a type of installation click Custom advanced 3 Click Load Driver ...

Страница 196: ...port DVD into the optical drive Click Browse to continue 5 Locate the driver in the corresponding folder of the Support DVD then click OK to continue 6 Select the RAID controller driver you need from the list and click Next 7 When the system finishes loading the RAID driver replace the motherboard Support DVD with the Windows Server installation disc Select the drive to install Windows and click N...

Страница 197: ...iver Disk OK Back Insert your driver disk into dev fd0 and press OK to continue Red Hat Enterprise Linux OS 5 x To load the LSI MegaRAID controller driver when installing Red Hat Enterprise OS 1 Boot the system from the Red Hat OS installation CD 2 At the boot type linux dd then press Enter To install or upgrade in graphical mode press the ENTER key To install or upgrade in text mode type linux te...

Страница 198: ...een instructions to finish the OS installation 7 When the installation is completed DO NOT click Reboot Press Ctrl Alt F2 to switch to the command line interface from graphic user interface 8 Type the following commands when using a Legacy floppy mkdir mnt driver mount dev fd0 mnt driver cd mnt driver sh replace_ahci sh reboot Do you wish to load any more driver disks ...

Страница 199: ... the following command at the boot Linux dd blacklist isci blacklist ahci nodmraid then press ENTER Red Hat Enterprise Linux OS 6 x To install the LSI MegaRAID controller driver when installing Red Hat Enterprise OS 1 Boot the system from the Red Hat OS installation CD 2 Press Tab to edit options ...

Страница 200: ... 5 You have multiple devices which could serve as source for a driver disk Choose one you like to use and select OK then press Enter OK Cancel Main Menu Yes No Driver Disk Sou8rce You have multiple devices which could serve as source for a driver disk Which would you like to use sdc sdd sdb sr0 Do you have a driver disk ...

Страница 201: ... RAID card are installed to the system 7 When asked if you will load additional RAID controller drivers select No then press Enter More Driver Disks Yes No Insert Driver Disk OK Back 8 Follow the onscreen instructions to finish the OS installation Insert your driver disk into dev sdb and press OK to continue Do you wish to load any more driver disks ...

Страница 202: ... a 64bit RAID driver for SUSE11 sp1 1 Copy the image file into the Linux system Example megasr 15 00 0120 2012 1 sles11 ga x86_64 img 2 Create a folder Example image 3 Mount the image file into the image folder using this command format mount oloop image file name image Example mount oloop megasr 15 15 00 0120 2012 1 sles11 ga x86__64 img image 4 Copy the contents of the image directory labeled as...

Страница 203: ...e menu Press Enter Installing SUSE 11 Linux OS To install the LSI MegaRAID controller driver when installing SUSE Linux Enterprise Server OS 1 Boot the system from the SUSE OS installation CD 2 Use the arrow keys to select Installation from the Boot Options menu ...

Страница 204: ...ve to provide the third party driver during the OS installation Type the command brokenmodules ahci in Boot Options field and press Enter 5 When below screen appears select the USB floppy disk drive sda as the driver update medium Select OK then press Enter Please choose the Driver Update medium sda USB Floppy other device OK Back ...

Страница 205: ... The contents of the support DVD are subject to change at any time without notice Visit the ASUS website www asus com for the latest updates on software and utilities 2 The support DVD is supported on Windows Server 2008 R2 and Windows Server 2012 The support DVD that is bundled with your motherboard contains drivers management applications and utilities that you can install to maximize the featur...

Страница 206: ...the available device drivers if the system detects installed devices Install the necessary drivers to activate the devices 6 3 2 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports 6 3 1 Drivers menu ...

Страница 207: ...iver disks 6 3 3 MakeDisk menu Press the arrow down button in the lower part of the menu to view more items 6 3 4 Manual menu The Manual menu provides the link to the Broadcom NetXtreme II Network Adapter user guide You need an internet browser installed in your OS to view the User Guide ...

Страница 208: ... 6 Driver Installation 6 3 5 Contact information menu The Contact menu displays the ASUS contact information e mail addresses and useful links if you need more information or technical support for your motherboard ...

Страница 209: ...r and then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 3 Click...

Страница 210: ...es to accept the terms of the License Agreement and continue the process 6 Read the Readme File Information and press Next to continue the installation 7 Toggle Yes I want to restart the computer now and click Finish to complete the setup process ...

Страница 211: ...rs Driver on the Windows operating system 1 Restart the computer 2 Log on with Administrator privileges 3 Insert the motherboard system support DVD to the optical drive If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 4 Click Intel I350 AM4 I350 AM2 I210 X540 AT2 ...

Страница 212: ...ions InstallShield Wizard window appears 7 Tick I accept the terms in the license agreement and click Next to continue 8 From the Setup Options window click Next to start the installation By default Intel R PROSet for Windows Device Manager and Windows PowerShell Module are ticked ...

Страница 213: ...ASUS Z10PC D8 Series 6 21 9 Click Install to start the installation 10 When the installation is done press Finish to complete the installation ...

Страница 214: ...ith Administrator privileges 2 Insert the motherboard system support DVD to the optical drive The support DVD automatically displays the Drivers menu if Autorun is enabled in your computer If Autorun is NOT enabled in your computer browse the contents of the support DVD to locate the file ASSETUP EXE from the BIN folder Double click the ASSETUP EXE to run the support DVD 3 Click the ASPEED AST2300...

Страница 215: ...ASUS Z10PC D8 Series 6 23 6 Click Finish to complete the installation 5 Click Install to proceed with the installation ...

Страница 216: ...Storage Technology enterprise 4 1 utility on a Windows operating system To install the Intel Rapid Storage Technology enterprise 4 1 utility 1 Restart the computer and then log on with Administrator privileges 2 Insert the motherboard system support DVD to the optical drive and find the utility menu 3 Click the Intel Rapid Storage Technology enterprise 4 1 to begin installation 4 When the Welcome ...

Страница 217: ...ASUS Z10PC D8 Series 6 25 5 Read the Warning message and click Next to continue 6 Read the License Agreement and click Yes to continue 7 Read the Readme File Information and click Next to continue ...

Страница 218: ... 6 Driver Installation 9 Select Yes I want to restart my computer now and click Finish to restart your computer before using the program 8 After completing the installation click Next to complete the setup process ...

Страница 219: ...ASUS Z10PC D8 Series A 1 A Appendix This appendix includes additional information that you may refer to when configuring the motherboard Appendix ...

Страница 220: ...A 2 Appendix Z10PC D8 Series block diagram Z10PC D8 SAS 10G 2S ...

Страница 221: ...ASUS Z10PC D8 Series A 3 Z10PC D8 SAS ...

Страница 222: ...A 4 Appendix Z10PC D8 10G 2S ...

Страница 223: ...ASUS Z10PC D8 Series A 5 Z10PC D8 ...

Страница 224: ...тствующим условиям соответствующих директив Подробную информацию пожалуйста смотрите на www asus com support Български С настоящото ASUSTeK Computer Inc декларира че това устройство е в съответствие със съществените изисквания и другите приложими постановления на свързаните директиви Пълният текст на декларацията за съответствие на ЕС е достъпна на адрес www asus com support Hrvatski ASUSTeK Compu...

Страница 225: ...dress 4F No 150 Li Te Rd Peitou Taipei 112 Taiwan Telephone 886 2 2894 3447 Fax 886 2 2890 7798 Web site https www asus com tw Technical Support Telephone 886 2 2894 3447 0800 093 456 Online Support https www asus com support Product ContactUs Services questionform lang zh tw ASUSTeK COMPUTER INC China Address No 5077 Jindu Road Minhang District Shanghai China Telephone 86 21 5442 1616 Fax 86 21 5...

Страница 226: ...Harkort Str 21 23 40880 Ratingen Germany Fax 49 2102 959911 Web site https www asus com de Technical Support Telephone 49 1805 010923 Support Fax 49 2102 959911 Online support https www asus com support Product ContactUs Services questionform lang de de ASUS Czech Service s r o Europe Address Na Rovince 887 720 00 Ostrava Hrabová Czech Republic Telephone 420 596766888 Web site https www asus com c...

Страница 227: ...ionform lang nl nl ASUS Polska Sp z o o Poland Address Ul Postępu 6 02 676 Warszawa Poland Web site https www asus com pl Technical Support Telephone 48 225718033 Online Support https www asus com support Product ContactUs Services questionform lang pl pl ASK Service Russia and CIS Address г Москва ул Орджоникидзе д 10 Россия Telephone 495 640 32 75 Web site https www asus com ru Technical Support...

Страница 228: ...C D8 SAS Z10PC D8 10G 2S Z10PC D8 Conforms to the following specifications FCC Part 15 Subpart B Unintentional Radiators Supplementary Information This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesi...

Отзывы: