Chapter 2: Hardware setup
2-24
2.7
Removable/optional components
You may need to remove previously installed system components when installing or removing
system devices. Or you may need to install the optional components into the system. This
section tells how to remove/install the system fans:
Ensure that the system is turned off before removing any components from your system.
2.7.1
System fans
To uninstall the system fans:
1.
Disconnect the system fan cable from the fan connector on the motherboard.
2.
Lift the fan, then set aside.
3.
Repeat steps 1 to 2 to uninstall the other system fans.
To reinstall the system fans
1.
Insert the fan to the fan cage.
RS400-E8-PS2
RS400-E8-PS2-F
2.
Connect the system fan cable to the fan connector on the motherboard.
Ensure that the fans are installed in the correct direction. For RS400-E8-PS2, the airflow
directional arrow on the fan side should point to the inner part of the chassis; for RS400-
E8-PS2-F, the airflow directional arrow on the fan side should point to the outer part of the
chassis