ASUS RS100-E5-PI2
6-9
6.2.6
Rebuilding the RAID
This option is only for the RAID 1 set.
Rebuilding the RAID with other non-RAID disk
If any of the SATA hard disk drives included in the RAID array failed, the system
displays the status of the RAID volume as “
Degraded
” during POST. You can
rebuild the RAID array with other installed non-RAID disks.
To rebuild the RAID with other non-RAID disk:
1. At the prompt, press <Ctrl> + <I> to enter the Intel Matrix Storage Manager
RAID configuration.
2. If there is a non-RAID SATA Hard Disk available, the utility will prompt to
rebuild the RAID. Press <Enter>, then use up/down arrow keys to select the
destination disk or press <ESC> to exit.
Select a destination disk with the same size as the original hard disk.
3. The utilty immediately starts rebuilding after the disk is selected. The status
of the degraded RAID volume is changed to
“Rebuild”
.
[
DEGRADED VOLUME DETECTED
]
[
↑↓
]-Previous/Next [SPACE]-Selects [ENTER]-Selection Complete
“Degraded“ volume and disk available for rebuilding detected.
Selecting a disk initiates a rebuild. Rebuild completes in the
operating system.
Select the port of destination disk for rebuilding (ESC to exit):
Port Drive Model
Serial#
Size
3HDS722580VLSA80
VN6Bxxxx
76.7GB
Intel(R) Matrix Storage Manager Option ROM v5.6.2.1002 ICH7R wRAID5
Copyright(C) 2003-06 Intel Corporation. All Rights Reserved.
1. Create RAID Volume
2. Delete RAID Volume
3. Reset Disks to Non-RAID
4. Exit
RAID Volumes:
ID Name Level Strip Size Status Bootable
0 Volume0 RAID0(Stripe) 128KB 306.8GB
Rebuild
Yes
Physical Disks:
Port Drive Model Serial # Size Type/Status(Vol ID)
0 Hitachi HDS72161 PVB300Z2R93D3D 153.4GB
Non-RAID Disk
3 Hitachi HDS72161 PVB300Z2R93D3D 153.4GB
Non-RAID Disk
[
↑↓
]-Select [ESC]-Exit [ENTER]-Select Menu
[
DISK/VOLUME INFORMATION
]
[
MAIN MENU
]
Содержание RS100-E5 - 0 MB RAM
Страница 1: ...RS100 E5 PI2 1U Rackmount Server User Guide ...
Страница 18: ...Chapter 1 Product introduction 1 8 ...
Страница 22: ...Chapter 2 Hardware setup 2 4 3 Secure the cover with one screw ...
Страница 145: ...A Reference information The Appendix describes the CPU features that the motherboard supports ...
Страница 148: ...A 4 Appendix CPU features ...