![Asus PRIME TRX40-PRO Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/asus/prime-trx40-pro/prime-trx40-pro_manual_2993032089.webp)
PRIME TRX40-PRO
4-1
Chapter 4
RAID Support
4
Chapter 4:
RAID Support
4.1
AMD RAID Array configurations
The motherboard comes with the RaidXpert2 Configuration Utility that supports Volume,
RAIDABLE, RAID 0, RAID 1, and RAID 10 (depends on system licensing) configurations.
For more information on configuring your RAID sets, please refer to the
RAID
Configuration Guide
which you can find at https://www.asus.com/support.
4.1.1
RAID definitions
Volume
provides the ability to link-together storage from one or several disks, regardless
of the size of the space on those disks. This configuration is useful in scavenging space on
disks unused by other disks in the array. This configuration does not provide performance
benefits or data redundancy, disk failure will result in data loss.
RAIDABLE
arrays (also known as RAID Ready) are a special type of Volume (JBOD) that
allows the user to add more storage space or create a redundant array after a system is
installed. RAIDABLE arrays are created using Option ROM, UEFI, or rcadm.
The ability to create RAIDABLE arrays may vary per system.
RAID 0 (Data striping)
optimizes two identical hard disk drives to read and write data in
parallel, interleaved stacks. Two hard disks perform the same work as a single drive but at a
sustained data transfer rate, double that of a single disk alone, thus improving data access
and storage. Use of two new identical hard disk drives is required for this setup.
RAID 1 (Data mirroring)
copies and maintains an identical image of data from one drive to
a second drive. If one drive fails, the disk array management software directs all applications
to the surviving drive as it contains a complete copy of the data in the other drive. This RAID
configuration provides data protection and increases fault tolerance to the entire system.
Use two new drives or use an existing drive and a new drive for this setup. The new drive
must be of the same size or larger than the existing drive.
RAID 10
is data striping and data mirroring combined without parity (redundancy data)
having to be calculated and written. With the RAID 10 configuration you get all the benefits
of both RAID 0 and RAID 1 configurations. Use four new hard disk drives or use an existing
drive and three new drives for this setup.
Содержание PRIME TRX40-PRO
Страница 1: ...Motherboard PRIME TRX40 PRO ...
Страница 16: ...xvi ...
Страница 40: ...1 24 Chapter 1 Product Introduction Chapter 1 ...
Страница 46: ...2 6 Chapter 2 Basic Installation Chapter 2 2 1 4 DIMM installation To remove a DIMM ...
Страница 47: ...PRIME TRX40 PRO 2 7 Chapter 2 2 1 5 ATX power connection AND Ensure to connect the two 8 pin power plugs ...
Страница 48: ...2 8 Chapter 2 Basic Installation Chapter 2 2 1 6 SATA device connection OR ...
Страница 52: ...2 12 Chapter 2 Basic Installation Chapter 2 For M 2_1 and M 2_2 Type 22110 M 2 ...
Страница 53: ...PRIME TRX40 PRO 2 13 Chapter 2 For M 2_3 Type 2242 2260 2280 22110 M 2 ...
Страница 62: ...2 22 Chapter 2 Basic Installation Chapter 2 ...
Страница 90: ...4 2 Chapter 4 RAID Support Chapter 4 ...