ASUS PIKE 2308
2-9
Esc = Exit Menu F1/Shift+1 = Help
SPACE/+/- = Select disk for volume C = Create volume
LSI Corp Config Utility v7.05.01.00 (2010.02.09)
Create New Volume -- SAS2308
Volume Type: RAID 1E
Volume Size(GB): -------
Slot Device Identifier RAID Drive Pred Size
Num
Disk Status Fail (GB)
0 ATA WDC WD800JD-22LS1D06
[No]
---------- No 74
1 ATA WDC WD800JD-22LS1D06
[No]
---------- No 74
2 ATA WDC WD800JD-22LS1D06
[No]
---------- No 74
3 ATA WDC WD800JD-22LS1D06
[No]
---------- No 74
By default, the RAID Disk
field shows
No
before volume creation. This field is grayed out
under the following conditions:
• The disk does not meet the minimum requirements for use in a RAID
volume.
• The disk is not large enough to mirror existing data on the primary drive.
• The disk is already part of another volume.
4.
Repeat step 3 to add the other disks to the volume.
5.
When done, press <C> to create the volume, then select Save changes then exit this
menu.
6.
The utility creates the volume.
Create and save new volume?
Cancel Exit
Save changes then exit this menu
Discard changes then exit this menu
Exit the Configuration Utility and Reboot
LSI Corp Config Utility v7.05.01.00 (2010.02.09)
Create New Volume -- SAS2308
Processing...may take up to 1 minute
Creating RAID Volume...