Chapter 2: Hardware setup
2-22
34
2.8.2 Removing/Add the chassis fan (Optional)
To remove the chassis fan:
1. Disconnect the chassis fan cable from the REAR_FAN1 connector on
the motherboard.
2. Locate and remove four chassis
fan screws at the rear panel. Keep
the screws for later use.
Hold the chassis fan with
one hand while removing the
chassis fan screws.
2
3. Remove the chassis fan, then set
aside.
3
3. Use the screwdriver secure the
screw that you removed earlier.
4. Move the drive bay lock toward
the rear panel to secure the lock.
5. Attach the FDD power and signal
cables to the connectors at the
back of the drive.
3
The chassis fan is purchased
separately.