5-24
Chapter 5: RAID configuration
5.2.6
Checking the drives for data consistency
You can check and verify the accuracy of data redundancy in the selected logical
drive. The utility can automatically detect and/or detect and correct any differences
in data redundancy depending on the selected option in the
Objects
>
Adapter
menu.
The
Check Consistency
command is available only for logical drives included
in a RAID 1 set.
Using the Check Consistency
To check data consistency using the
Check Consistency
command:
1. From the
Management Menu
, select
Check Consistency
, then press
<Enter>.
2. The screen displays the available RAID set(s) and prompts you to select the
logical drive to check. Press the <Spacebar> to select the logical drive from
the
Logical Drive
selection, then press <F10>.
Содержание P5BV - Motherboard - ATX
Страница 1: ...Motherboard P5BV Series P5BV P5BV SAS ...
Страница 13: ...1 Product introduction This chapter describes the motherboard features and the new technologies it supports ...
Страница 56: ...ASUS P5BV Series Chapter summary 3 3 1 Starting up for the first time 3 1 3 2 Powering off the computer 3 2 ...
Страница 96: ...4 36 Chapter 4 BIOS setup ...
Страница 162: ...6 Chapter 6 Driver installation ICH7R INTEL RAID Driver ICH7R LSI RAID Driver LSI 1068 SAS Driver ...
Страница 182: ...ASUS P5BV Series Chapter summary A A 1 P5BV block diagram A 1 A 2 P5BV SAS block diagram A 2 ...