5-15
ASUS ESC8000 G3
Parity [None]
A parity bit can be sent with the data bits to detect some transmission errors. [Mark]
and [Space] parity do not allow for error detection.
[None]
None
[Even]
parity bit is 0 if the num of 1’s in the data bits is even
[Odd]
parity bit is 0 if num of 1’s in the data bits is odd
[Mark]
parity bit is always 1
[Space]
parity bit is always 0
Stop Bits [1]
Stop bits indicate the end of a serial data packet. (A start bit indicates the beginning.)
The standard setting is 1 stop bit. Communication with slow devices may require more
than 1 stop bit.
Configuration options: [1] [2]
Flow Control [Hardware RTS/CTS]
Flow control can prevent data loss from buffer overflow. When sending data, if the
receiving buffers are full, a “stop” signal can be sent to stop the data flow. Once the
buffers are empty, a “start” signal can be sent to re-start the flow. Hardware flow control
uses two wires to send start/stop signals.
Configuration options: [None] [Hardware RTS/CTS]
VT -UTF8 Combo Key Support [Enabled]
This allows you to enable the VT -UTF8 Combination Key Support for ANSI/VT100
terminals. Configuration options: [Disabled] [Enabled]
Recorder Mode [Disabled]
With this mode enabled only text will be sent. This is to capture Terminal data.
Configuration options: [Disabled] [Enabled]
Legacy OS Redirection Resolution [80x24]
This allows you to set the number of rows and columns supported on the Legacy OS.
Configuration options: [80x24] [80x25]
Putty Keypad [VT100]
This allows you to select the FunctionKey and Keypad on Putty.
Configuration options: [VT100] [LINUX] [XTERMR6] [SCO] [ESCN] [VT400]
Redirection After BIOS POST [Always Enable]
This setting allows you to specify if Bootloader is selected than Legacy console
redirection.
Configuration options: [Always Enable] [Bootloader]
Содержание ESC8000 G3
Страница 1: ...3U Rackmount Server ESC8000 G3 User Guide ...
Страница 28: ...Chapter 2 Hardware Setup 2 6 2 Carefully lift the CPU air duct 3 Loosen the screws on the CPU heatsink ...
Страница 35: ...2 13 ASUS ESC8000 G3 19 Replace the CPU air duct 20 Tighten the screws on the CPU air duct ...
Страница 62: ...4 2 Chapter 4 Motherboard Information 4 1 Z10PG D24 Motherboard layout ...
Страница 84: ...4 24 Chapter 4 Motherboard Information ...
Страница 136: ...5 52 Chapter 5 BIOS Setup ...
Страница 176: ...6 40 Chapter 6 RAID Configuration ...
Страница 199: ...ASUS ESC8000 G3 7 23 6 Click Finish to complete the installation 5 Click Install to proceed with the installation ...
Страница 203: ...Appendix This appendix includes additional information that you may refer to when configuring the motherboard Appendix ...