![Asus ESC4000 G3 Series Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/asus/esc4000-g3-series/esc4000-g3-series_user-manual_26734056.webp)
Chapter 2: Hardware setup
2-28
•
The system automatically combines the two power supply modules as a single one.
The combined output power varies with input voltages. Refer to the table below for
details.
1620W
Input Voltage
Max. Output Power (Watt) per PSU
100V—120Vac, 12-10A, 50-60Hz
1000W
120V—140Vac, 12-10A, 50-60Hz
1200W
180V—240Vac, 10.5-8A, 50-60Hz
1620W
2000W
Input Voltage
Max. Output Power (Watt) per PSU
100-120Vac, 12.7-10.5A, 50-60Hz
1100W
120-140Vac, 13.5-11.5A, 50-60Hz
1400W
200-220Vac, 10.0-9.5A, 50-60Hz
1800W
220-230Vac, 10.0-9.8A, 50-60Hz
1980W
230-240Vac, 10.0-9.8A, 50-60Hz
2000W
•
To enable the hot-swap feature (redundant mode), keep the total power consumption
of the system under the maximum output power of an individual power supply module.
•
Always use PSUs with the same watt and power rating. Combining PSUs with different
wattage (e.g. 1 x 1620 W + 1 x 2000 W) may yield unstable results and potential
damage to your system.
•
For a steady power input, use only the power cables that come with the server system
package.
Содержание ESC4000 G3 Series
Страница 1: ...2U Rackmount Server ESC4000 G3 G3S Series User Guide ...
Страница 12: ...xii ...
Страница 28: ...Chapter 1 Product introduction 1 16 ...
Страница 66: ...Chapter 3 Installation options 3 6 ...
Страница 68: ...4 2 Chapter 4 Motherboard information 4 1 Z10PG D16 Motherboard layout ...
Страница 136: ...5 52 Chapter 5 BIOS setup ...
Страница 176: ...6 40 Chapter 6 RAID configuration ...
Страница 206: ......