5-42
Chapter 5: BIOS setup
5.8
Monitor menu
The Monitor menu displays the system temperature/power status, and allows you to change
the fan settings.
CPU1 Temperature
60.0ºC/140.0ºF
CPU2 Temperature
54.5ºC/130.1ºF
TR1 Temperature
26.8ºC/80.2ºF
TR2 Temperature
27.0ºC/80.6ºF
FRNT FAN1 Speed
7031 RPM
FRNT FAN2 Speed
3948 RPM
FRNT FAN3 Speed
4005 RPM
FRNT FAN4 Speed
7105 RPM
FRNT FAN5 Speed
7142 RPM
FRNT FAN6 Speed
3580 RPM
FRNT FAN7 Speed
3452 RPM
+VTT_CPU
+1.044 V
VCORE1
+0.960 V
VCORE2
+0.962
+VDDQ_AB_CPU1
+1.510 V
+VDDQ_CD_CPU1
+1.526 V
+VDDQ_EF_CPU2
N/A
+VDDQ_GH_CPU2
N/A
+5VSB +4.921 V
+5V
+5.036 V
+12V +11.592 V
+3.3V +3.276 V
VBAT +3.168 V
+3.3VSB
+3.234 V
CPU 1/2; MB; TR1/TR2 Temperature [xxx°C/xxx°F]
The onboard hardware monitor automatically detects and displays the CPU and motherboard
component temperatures. Select
Ignore
if you do not wish to display the detected
temperatures.
FRNT FAN1–7 Speed; [xxxx RPM] or [Ignore] / [N/A]
The onboard hardware monitor automatically detects and displays the speed of CPU fans,
front fans, and rear fan in rotations per minute (RPM). If the fan is not connected to the
motherboard, the field shows
N/A
.
+VTT_CPU Voltage, VCORE1/2 Voltage, +VDDQ_AB_CPU1 Voltage, +VDDQ_
CD_CPU1 Voltage, +VDDQ_EF_CPU2 Voltage, +VDDQ_GH_CPU2 Voltage,
+5VSB Voltage, +5V Voltage , +12V Voltage, +3.3V Voltage, VBAT Voltage,
+3.3VSB Voltage
The onboard hardware monitor automatically detects the voltage output through the onboard
voltage regulators.
FAN Speed Control [Generic Mode]
Allows you to configure the ASUS Smart Fan feature that smartly adjusts the fan speeds for
more efficient system operation.
Configuration options: [Generic Mode] [High Speed Mode] [Full Speed Mode]
Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
Main Advanced Server Mgmt Event Logs Boot
Monitor
Security Tool Exit
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
→←:
Select Screen
↑↓:
Select Item
Enter: Select Item
+/-: Change Opt.
F1: General Help
F2: Previous Values
F5: Optimized Defaults
F10: Save & Exit
ESC: Exit
Disable: Voltage monitor.
Enabled: Temperature monitor.
Содержание ESC4000 G2S
Страница 1: ...2U Rackmount Server ESC4000 FDR G2S ESC4000 G2S User Guide ...
Страница 12: ...xii ...
Страница 22: ...Chapter 1 Product introduction 1 10 ...
Страница 51: ...2 29 ASUS ESC4000 G2S Series 14 Secure the accelerator brackets to the server chassis with four screws ...
Страница 52: ...Chapter 2 Hardware setup 2 30 ...
Страница 58: ...4 2 Chapter 4 Motherboard information 4 1 Motherboard layout Z9PG D16 FDR Z9PG D16 ...
Страница 74: ...4 18 Chapter 4 Motherboard information ...
Страница 160: ...6 40 Chapter 6 RAID configuration ...
Страница 202: ......