Chapter 3
–
Gateway Setup and Configuration
22
IO
T G
at
eway
Sy
ste
m
SPG
-M0
41
Label
Interface
Connector Type
Description
1
Reset
Push button
Reboot: Use a pointed object to press
reset button to reboot.
2
V1-
Terminal block
Negative pole of power input 1
3
V1+
Terminal block
Positive pole of power input 1
4
V2-
Terminal block
Negative pole of power input 2
5
V2+
Terminal block
Positive pole of power input 2
6
Ground
Terminal block
Earthing point for power supply
7
Ground
screw
-
-
•
Insert a small flat-bladed screwdriver in the V1-/V1+ wire-clamp screws and
loosen the screws
•
Insert the negative/positive DC wires into the V1-/V1+ terminals of DC1. If
power redundancy is enabled, connect DC2 in the same manner
•
Tighten the wire-clamp screws to secure the DC wires in place
•
Insert the terminal block and press it in until it is flush with the terminal block
receptor on the SPG-M041