background image

6.

 

Microstep Resolution and Driver Current Output

 

 

This driver uses an 8-bit DIP switch to set microstep resolution, dynamic current and standstill current, 
as shown below: 

Current during motion   Microstep resolution 

 

 

Microstep Resolution Selection

 

Microstep resolution is set by DIP SW5, 6, 7, 8 as shown in the following table: 

 

Microstep Step/rev.(for 

1.8

°

motor) SW5 SW6 SW7 SW8 

No 

rotation 

off off off off 

400 

on on on on 

800 

on off on on 

8 1600 on 

on 

off 

on 

16 3200 on 

off 

off 

on 

32 

6400 

on on on off 

64 

12800 

on off on off 

128 25600  on 

on 

off 

off 

256 51200  on 

off 

off 

off 

5 1000 off 

on 

on 

on 

10 2000 off 

off 

on 

on 

25 

5000 

off on off on 

50 

10000 

off off off on 

125 25000  off 

on 

on 

off 

250 50000  off 

off 

on 

off 

 

Current Setting 

The first three bits (SW1, 2, 3) of the DIP switch are used to set the current during motion (dynamic 
current), while SW4 is used to select standstill current. 

 

P808 DIP Selection for current during motion: 

Current for P808 

SW1 

SW2 

SW3 

2.8A on on on 
3.5A off on 

on 

4.2A on off on 
4.9A off off on 
5.7A on on off 
6.4A off on off 
7.0A on off off 
7.7A off off off 

Note: due to motor inductance, actual coil current may be smaller than dynamic current settings, particularly at higher speeds.  

DIP Selection for current during standstill: 

SW4 is used for this purpose, current setting due to coil inductance. OFF meaning that the standstill 
current is set to be half of the dynamic current and ON meaning that standstill current is set to be the 
same as dynamic current. 

Astrosyn International Technology Ltd, The Old Courthouse, New Rd Ave, Chatham, Kent   ME4 6BE, England

 

Tel: +44(0)1634 815175                 Fax: +44(0)1634 826552 

 

Содержание P808

Страница 1: ...User Manual Model P808 High Performance Microstepping Driver Astrosyn International Technology Ltd The Old Courthouse New Rd Ave Chatham Kent ME4 6BE England Tel 44 0 1634 815175 Fax 44 0 1634 826552...

Страница 2: ...t control for less motor heating z 14 selectable step resolutions in decimal and binary z Microstep resolutions up to 51 200 steps rev z Suitable for 4 6 or 8 lead motors z Over current over voltage a...

Страница 3: ...this signal is used for enable disable high level for enabling driver and low level for disabling driver Usually left unconnected enabled Remark 1 Pul dir is the default mode internal jumper JMP1 can...

Страница 4: ...r and ground in the wrong way it will damage the driver 5 Driver Voltage and Current Selection This driver can match small medium size step motors NEMA 17 23 34 and 42 To achieve good driving results...

Страница 5: ...ff Current Setting The first three bits SW1 2 3 of the DIP switch are used to set the current during motion dynamic current while SW4 is used to select standstill current P808 DIP Selection for curren...

Страница 6: ...lt in high speed optocoupler and can accept signals in the format of line driver open collector or PNP output Line driver differential signals are suggested for reliability In the following figures co...

Страница 7: ...and motor speed can be significantly increased Serial connection will lead to increased inductance and thus the motor can be run well only at lower speeds 9 Connection Diagram A complete stepping syst...

Страница 8: ...be established at least 2 s before the first pulse of the next pulse train Please examine the timing diagrams of the three control signals as follows 11 Dimensions External dimensions are shown in mm...

Отзывы: