10  

LOW TEMPERATURE MODE

  

 

In Low Temperature (Sentinel) mode, system starts your engine automatically when the temperature falls below a preset 
level.  
Engine will run for programmed runtime, after which the system will wait 2½ hours and then start the engine again if 
temperature is still below preset level.  
To activate/cancel Low Temperature mode, press buttons simultaneously. 
 

When mode is activated: 

 

Parking lights will flash 4 times, then, if temperature is below preset level, 

engine will start.  

If temperature is above preset level, system will wait until it goes below the preset level before starting engine. 
In the case of a manual transmission vehicle, the system must have detected a valid security sequence to allow the 

activation of Low Temperature mode. (see “Safety sequence for manual transmission vehicles” on page 2). 

If system cannot execute command (for example, security sequence not valid, hood is open), confirmation will be different 

(lights: 3). 

When mode is cancelled:  

Parking lights will flash twice to confirm that mode is cancelled. Applying brakes cancels Low Temperature mode. 

S

ETTING THE START TEMPERATURE

 

 

 

To change preset temperature at which you want your Remote Starter to start 
engine, press  

  and  

 buttons simultaneously (lights: 1 - 4).  

Parking lights will flash from 1 to 4 times to indicate selected start temperature (see 
table opposite). 
If you send command when ignition has been turned on (by Remote Starter or key), 
preset start temperature does not change. However, confirmation is still sent to 
indicate last selection. 

 

S

ETTING THE RUNTIME 

 

 

Press buttons  

   and  

  simultaneously (parking lights: 1 - 4).  

Parking lights flash one to four times to indicate selected runtime (see table 
opposite). 
If you send this command while the ignition circuits are activated (by remote or key), 
runtime does not change but confirmation is sent to indicate last selection. 
If Low Temperature mode is already activated when this command is sent, the 
command sets or indicates Low Temperature mode runtime. 

Note:

 Runtime is doubled for a diesel engine. 

                                                                                 

1

 A runtime of 2 minutes (4 min. for a diesel engine ) is not recommended for most vehicles unless you intend to drive off immediately after the remote start. This 

selection is not available in Low Temperature mode. 

Remote controls 

4-button 5-button 6-button 

 

 

 

 

 

 

Number of  

Flashes 

Preset start 

temperature  

1 -5°C 

(23°F) 

2 -15°C 

(5°F) 

3 -20°C 

(-7°F) 

4 -30°C 

(-22°F) 

Number of 

flashes  

Runtime 

1 2 

minutes 

1

 

2 4 

minutes 

3 8 

minutes 

4 18 

minutes 

Содержание 2205A

Страница 1: ...acturedinCanadaby Printed in Canada All rights reserved Astroflex 2006 2 WAY REMOTE CONTROL ENGINE STARTER U S E R M A N U A L For all gas and diesel powered vehicles FRAN AIS AU VERSO CONSULT SAFETY...

Страница 2: ...against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual...

Страница 3: ...rter to which an alarm kit has been added Both models offer a keyless entry feature allowing the user to operate the door locks as well as access to the trunk of the vehicle These features are optiona...

Страница 4: ...starter checked annually Contact a dealer in your area All users of the vehicle should be aware of the safety precautions and operation procedures Make sure that the warning sticker is present on the...

Страница 5: ...that the Turbo Mode is unavailable with this option The parking lights will blink once to confirm that the sequence is valid vehicle is ready for a remote start command The end of sequence option is...

Страница 6: ...n the vehicle These signals are transmitted only once and could be neutralized by radio or electromagnetic interferences generated by electronic devices in the vicinity If no confirmation is received...

Страница 7: ...hile engine is stopped and key is not in the ignition or while engine is remote started see Valet Mode on page 14 The valet switch is a small red push button hided under the dash board Parking lights...

Страница 8: ...H ORN P ARKING LIGHTS SIREN 4 BUTTON 5 BUTTON S TART C ONTINUOUS MODE 1 1 S TOP 1 L OCK A RMING 1 1 3 1 3 X P ANIC 5 sec or 5 sec 30 60 SEC U NLOCK D ISARMING 2 4 2 4 X T RUNK _ 5 sec 3 3 A CTIVATE C...

Страница 9: ...TRUNK IS OPEN THIS CONFIRMATION WILL REPEAT ITSELF EVERY 5 MINUTES UNTIL THE TRUNK IS CLOSED W HEN THE DOOR AND TRUNK ZONE ARE IN VIOLATION AT THE SAME TIME THE LCD DISPLAY WILL SHOW THE D OOR ZONE EX...

Страница 10: ...twice depending on reason for failure to start After three attempts it will shut down automatically and wait for a new command In this case confirmations sent by the vehicle are the same but remote co...

Страница 11: ...If Turbo Mode is on it will be activated when the safety sequence is executed Remove the key exit vehicle and lock all doors All safety devices will remain active If you return to your vehicle before...

Страница 12: ...preset temperature at which you want your Remote Starter to start engine press and buttons simultaneously lights 1 4 Parking lights will flash from 1 to 4 times to indicate selected start temperature...

Страница 13: ...or horn PREVENTIVE Depending on the system s configuration the indicator light shows different alarm conditions see ZONE CODES on page 14 It can also act as a deterrent if installed in a place visible...

Страница 14: ...on this vehicle Following table shows effect of each zone on rearming cycle Protection zone Effect on rearming cycle Hood Additional sensor trunk Shock sensor These three zones prolong rearming cycle...

Страница 15: ...ed the system sends another confirmation one chirp or flash if all zones are in normal condition three chirps or flashes if another zone is in violation If a zone is in violation when system is armed...

Страница 16: ...confirms that Temporary Valet Mode has been activated To cancel this mode place ignition key in RUN position then remove it passive rearming is reactivated when you open a door You can also arm the sy...

Страница 17: ...onged by the number of seconds during which dome light is kept on by vehicle s factory system Special condition If during dome light duration a Lock command is sent while a door is opened system arms...

Страница 18: ...ry installed security system and that this system is neutralized by the trunk release command remember to rearm it after trunk is closed Lock command SYSTEM EQUIPPED WITH AN ADDITIONAL SENSOR If your...

Страница 19: ...ped additional optional equipment required The message is sent again after 30 seconds and then every two minutes for as long as the lights remain on This function is only available on gas powered vehi...

Страница 20: ...g by ignition key Use the stop command to abort panic mode START FAIL CODES When a remote start attempt fails it is possible to determine what caused the failure to start Press the and buttons simulta...

Страница 21: ...be present and operational See Safety checks on page 19 Place key in the ignition and turn to the RUN position Apply the brakes once You now have 10 seconds to turn the key from RUN to the OFF positi...

Страница 22: ...pply the brakes 2 Release the parking brake The engine must stop immediately upon releasing the parking brake If the engine does not stop which is not safe place the main switch in OFF position until...

Отзывы: