T3-OPX installation
T3-OPX User Guide
30
All parts require printing and scanning the result. The print unit will calibrate the nozzles and ink
drop based on the scans. Below is an overview of the Diagnostics menu:
Prerequisites
•
1 x scanner (EPSON v600)
•
High grade ColorLok paper (Minimum A4), 160 grs (or heavier)
•
Print height is calibrated to the high grade paper height
•
Media entry sensor is calibrated to the high grade paper
Nozzle alignment
1.
Open the
Diagnostics
menu.
2.
Press
Print Nozzle Alignment Plot
.
3.
Place the paper on the table.
4.
Press
Print Nozzle Alignment chart
.
5.
Examine the print.