Publication No. 980956 Rev. A 346B User Manual
Astronics Test Systems
Calibration Procedure 4-1
Chapter 4
Calibration Procedure
The 346B Synthesized Calibrator is packaged on a single, printed circuit board. All
the adjustments are accessible from the top of the unit with the top cover
removed.
Test Equipment
Note: Equivalent equipment can be substituted.
Digital Multimeter
Keithley 191
Voltage to Charge Converter
Trig-Tek 2030
Charge Amplifier
Trig-Tek 203M
Distortion Analyzer
Hewlett Packard 334A
Procedure
Before turning on the unit, check the 115-230 VAC switch S1,
Figure 4-1,
near the
transformer for proper setting to accommodate the power to be used. Connect
the power cord to AC power and place the ON-OFF switch to ON.
Figure 4-1, 115-230 VAC Switch S1