4.

 

Set up the Measurement Program 

4.1.

 

Introduction 

Each measurement consists of 3 different files. All files are readable with a text editor. 

Type 

Function 

Measurement Program File (*.mpr) 

This file contains the general structure of the measurement. It can 
be  created  with  the  Editor  Tool  (CCCC  Tool).  If  one  wants  to 
implement  a  custom  software  or  script  to  create  measurement 
flows,one should refer to the step syntax documentation. 

Data File(*.dat) 

The  Data  File  is  created  by  the  CCCC  Software  during  a 
measurement. It contains the measurement data recorded by the 
device. 

Log File (*.log) 

This  File  contains  all  the  events  that  took  place  during  the 
measurement. For example if the measurement was canceled or if 
a counter was set to a specific value during the data recording. 

The files should not be separated from each other during a measurement. Otherwise the CCCC Software will not recognize preexisting 
data and is going to create a new Data File in the folder of the Measurement Program File. 

However if one likes to share the data after a recording, it is sufficient to pass 
just the Data File because it contains all the essential information to visualize 
the results. 

 

 

This window shows the configuration page of a 
cyclovoltametric step

 

Содержание BAT-FLEX

Страница 1: ...e specifications without notice Bat FLEX Manual 1 19 AD 10069 007 Rev 03 BAT FLEX Manual Rev Remarks changes created checked released 01 Initial ported RT 01 03 13 AST 01 03 13 AST 01 03 13 03 Correct...

Страница 2: ...ard 7 2 5 3 BatFlex Small Dual Card 7 3 CCCC Setup 8 3 1 Preparation 8 3 2 Communication Setup 8 3 3 CCCC Overview 9 4 Set up the Measurement Program 10 4 1 Introduction 10 4 2 Measurement Flow 11 4 3...

Страница 3: ...cription how to set the device IP can be found in the BatFlex FPGA Card Menu Guide Ethernet User PC 1 2 Direct Connection Please read Appendix A How to set up a static IP for further instructions User...

Страница 4: ...ected or unavoidable maintenance of the network could cause measurement data loss 2 3 Card Types The BatFlex Device is designed as amodular System where measurement cards can be replaced whenever the...

Страница 5: ...by turning the wheel to the left or to the right Selections are confirmed by pressing the wheel The SD card slot can be used to upgrade the firmware of the device USB and JTAG are for service and deb...

Страница 6: ...ice FPGA IMG from SD A new FPGA image will be transferred from the SD card to the device This is a major update which means that the entire software is renewed Firmware from SDCard The FPGA boots up s...

Страница 7: ...gnation 2 5 4 1 Specification Channels Details Value Unit Number of channels 8 Pcs Current measurement Details Value Unit Resolution 188 uA 100 pA 750 uA 400 pA 3 mA 1 5 nA 24 mA 12 nA Accuracy full s...

Страница 8: ...needs to be restarted On startup the application searches for a viable device on the Network If the device is not yet configured the first action after the main window shows up is to get into the comm...

Страница 9: ...esn t switch automatically to constant current mode The range can be chosen by clicking on I and selecting the appropriate range in the dropdown menu Output Modes Constant voltage By clicking on Uout...

Страница 10: ...is created by the CCCC Software during a measurement It contains the measurement data recorded by the device Log File log This File contains all the events that took place during the measurement For e...

Страница 11: ...en move from position to position during the execution Each step has its unique ID and can be configured with individual parameters It s also possible to jump between the steps by setting conditions t...

Страница 12: ...ostatic Step This step implements a galvanostat or current source Its main purpose is to keep the current through the cell constant disregarding changes in the load itself This step offers a condition...

Страница 13: ...channel has to be selected After that the measurement window can be opened The measurement window contains control elements to start stop and pause the data recording as well as a table with the curre...

Страница 14: ...irst step is a counter step which sets the cycle counter to one The following two steps are galvanostatic steps which charge discharge with a constant current until the defined end voltage is reached...

Страница 15: ...Tool offers two main methods to display the data as a CV diagram Current Voltage or as a time dependent diagram There are many customizable parameters to get the best view on the desired data 7 Expor...

Страница 16: ...twork card with up to date network drivers Open the Network and Sharing Center This can be found in the Control Panel under Network and Internet A Control Panel can be opened by pressing Windows R the...

Страница 17: ...ddress This will activate the input fields One should use the data obtained in the first step to complete the Subnet mask Gateway and the DNS server addresses The computer will change the IP address a...

Страница 18: ...e 1 Guard 2 Never connect different guard types the device could be damaged 2 Aux 2 3 Guard 2 4 Guard 2 5 Aux 2 6 Guard 2 7 NC Not connected 8 Guard 1 9 Aux 1 10 Guard 1 11 Guard 1 12 Out 1 13 Guard 1...

Страница 19: ...l with serial number 11 2 Inside Type label with serial number on the left side 12 Order code Type Order Code BatFlex Base Device with Reference Card AA 10320 001 Bat Flex Small Dual 8 Channels AA 103...