4

4

.

.

 

 

 

 

M

M

E

E

N

N

U

U

S

S

 

 

&

&

 

 

I

I

C

C

O

O

N

N

S

S

 

 
 

 

 

 Dash 8Xe / Dash 8X screen highlighting the Menu Bar and Control Panel 

 

 

MENU BAR 

The menu bar is a group of drop-down menus located across the top of the display.  
All 

Dash 8Xe / Dash 8X

 modes and features can be accessed from this menu.  Options 

available from the menu bar will vary based on the mode of operation (Realtime, Scope, or 
Review) used. 
 
If the date and time are visible instead of the menu bar, choose the 

icon in the upper right 

hand corner, which toggles the display of date/time and menu bar. 
 

 

 
 

 

File

  

 

 

The File menu is used to save and load your setup files. 

 

Configuration 

The Configuration menu is used to select the operation of the 

Dash 8Xe / Dash 8X

.  

 

View 

 

 

The View menu is used to supplement the graph display of your signals. 

 

Setup 

 

 

The Setup menu is used to configure the 

Dash 8Xe / Dash 8X

 

Cursors 

 

The Cursors menu is used for time and amplitude measurements. 

 

Capture

 

 

The Capture menu is used to setup, arm, manual trigger, and abort data captures. 

 

Service 

 

 

The Service menu is for less frequently used parameters such as calibration and security settings. 

 

Chart

   

 

The Chart menu provides for operation of the optional SCR-8 thermal recorder. 

 

Help

 

 

 

The Help menu provides for on-line assistance. 

 
 
 

CONTROL PANEL 

The control panel is an array of icon-based icons located on the right hand side of the display. 
The icon icons allow for a single touch to execute a function. The 

Dash 8Xe / Dash 8X

 ships 

with the control panel displaying icon icons for speed control, analog set up, meter mode, and 
run/halt. 
 
The control panel can be customized to add or remove icon icons to suit your recording 
needs. Further, the control panel settings can be saved to a file for later recall making test 
preparation very easy. 
 

 

Содержание Dash 8X

Страница 1: ...Up the Display Appearance 7 Amplifier Settings 8 Sample Exercises 9 Archiving Data Records 10 Entering Engineering Units 11 Powering Down Astro Med Incorporated Test Measurement Product Group Astro Me...

Страница 2: ...ity to modify the display based on the needs of the user or application 2 2 G GE ET TT TI IN NG G S ST TA AR RT TE ED D Voltage Verification The Dash 8Xe Dash 8X has an auto sensing power supply that...

Страница 3: ...Setup The Setup menu is used to configure the Dash 8Xe Dash 8X Cursors The Cursors menu is used for time and amplitude measurements Capture The Capture menu is used to setup arm manual trigger and ab...

Страница 4: ...pply saves the information you modified in a window without closing the window Select All selects highlights all items in a list box Clear Selection removes the selections highlights from all items in...

Страница 5: ...ANCE SETTING UP THE DISPLAY APPEARANCE The Dash 8Xe Dash 8X gives you total control over chart layout You can set individual channel widths channel location grids ON OFF and major minor division sizin...

Страница 6: ...teps to take using the pull down menus of the Menu Bar I Real time Monitoring Monitor the voltage of a 9 Volt battery Set up the channel so that when there is no signal the waveform trace will be at t...

Страница 7: ...ss OK Input battery voltage into Channel 1 Use the banana jack input connection located on the side of the Dash 8Xe Dash 8X and input the battery voltage into Channel 1 Measure the battery voltage usi...

Страница 8: ...00 Set capture for 10 seconds In the Storage Allocation box press the units pull down box and select Seconds Other choices are minutes hours and Ksamples Press the value box to open the Seconds Window...

Страница 9: ...trigger when 9 Volts is applied Press the Trigger Level icon 1ST icon in the row of icons at the bottom In the Trigger Level window highlight Waveform 1 Press Level Then press New Value Press the digi...

Страница 10: ...to enter the Review Mode Select file to be reviewed Click on the top most file name to highlight the capture Press OK Data Capture Review of 9 Volt battery data capture Show entire capture Choose Dis...

Страница 11: ...the A cursor icon Slide the cursor just to the left of the trigger point Press the B cursor icon Slide the cursor just to the right of the trigger point Time measurements using cursors Choose View Sta...

Страница 12: ...e Files on data capture drive not Windows system drive Select to review or archive Selected file will be highlighted Archived Data Captures Lists archived data capture files on Windows system or exter...

Страница 13: ...ile Select the Archive File icon to archive the selected file A status pop up will appear showing the percentage completed Once the file has completed archiving select OK to exit the Review mode scree...

Страница 14: ...example we will assume we are entering the engineering units for a current probe that provides a 10mV A voltage output to the Dash 8Xe Dash 8X Dash 8Xe Dash 8X Amplifier Channel Settings Analog Chann...

Страница 15: ...G D DO OW WN N When the power switch is set to the off position or if AC power is lost or removed the Dash 8Xe Dash 8X begins the power down sequence This is indicated by the green LED next to the pow...

Отзывы: