Installation and Operation Instructions

Astria™ Unvented (Vent-Free) Yellow Flame 

Fireplace

Models

Zeta21ZMN   F1241

Zeta21ZMP   F1242

Report No. F09-168

P/N 126885-01 Rev.  B 04/2015

PFS

®

US

P126885-01

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not 

prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This 

appliance is not convertible for use with other gases.

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions 

for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation 

section on page 6 of this manual.

 

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

 

 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance.

 

 WHAT TO DO IF YOU SMELL GAS: 

•   Do not try to light any appliance. 

•   Do not touch any electrical switch; do not use any phone in your building. 

•   Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. 

•  If you cannot reach your gas supplier, call the fire department.

 

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Содержание Zeta21ZMN F1241

Страница 1: ...h it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on page 6 of this manual WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the...

Страница 2: ...r nausea If you have these signs the fireplace may not be working properly Get fresh air at once Have fireplace serviced Some people are more affected by carbon monoxide than others These include pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes Natural and Propane LP Gas Natural and propane LP gases are odorless An odor mak...

Страница 3: ...ith the fireplace 6 Do not add extra logs or ornaments such as pine cones vermiculite or rock wool Using these added items can cause sooting Do not add lava rock around base Rock and debris could fall into the control area of fireplace 7 This fireplace is designed to be smokeless If logs ever appear to smoke turn off fireplace and call a qualified service person Note During initial operation sligh...

Страница 4: ...sachusetts The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Mas sachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Vent free gas products are prohibited for bedroom and bathroom installation in the Commonwealth of Massachusetts COMMONWEALTH OF MASSAC...

Страница 5: ...E Tools Required Phillips screwdriver 5 16 hex wrench slotted screwdriver scissors 1 Remove two screws that hold fireplace screen in place for ship ping These screws are located near top of screen Discard screws Lift fireplace screen up and pull out to remove see Figure 2 Set screen aside until installation has been completed 2 Remove all packaging from inside of unit 3 Remove bubble wrap from log...

Страница 6: ... three criteria you must provide additional fresh air See Ventilation Air From Outdoors page 8 If your home does not meet all of the three criteria above proceed to Determining Fresh Air Flow For Fireplace Location Confined and Unconfined Space The National Fuel Gas Code ANSI Z223 1 NFPA 54 defines a con fined space as a space whose volume is less than 50 ft3 per 1 000 Btu hr 4 8 m3 kw of the aggr...

Страница 7: ... fresh air would come from an adjoining unconfined space When ventilating to an adjoining unconfined space you must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 4 You can also remove door into adjoining room see option 3 Figure 4 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Secti...

Страница 8: ...d depth of the fireplace Use the dimensions shown for rough openings to create the easiest installation see Built In Fireplace Installation page 9 CHECK GAS TYPE Use the correct gas type natural or propane LP for your unit If your gas supply is not correct do not install fireplace Call dealer where you bought fireplace for proper type fireplace WARNING This appliance is equipped for natural or pro...

Страница 9: ...ont Width 19 3 4 17 1 2 Depth 8 7 8 8 7 8 Bottom 0 0 1 Frame in rough opening Use dimensions shown in Figure 7 for the rough opening If installing in a corner use dimensions shown in Figure 8 for the rough opening The height is 22 1 4 which is the same as the wall opening above 2 Install gas piping to fireplace location This installation includes an approved flexible gas line if allowed by local c...

Страница 10: ...e 10 Make sure to locate access hole so cabinet mantel will cover it when installed Note You can secure base to floor using wood screws Countersink screw heads and putty over 3 Route flexible gas line through access hole in hearth base 4 Center cabinet mantel on hearth base see Figure 11 Make sure mantel is flush against wall and centered left to right on base 5 Use hardware provided with mantel a...

Страница 11: ...place If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locate NPT tap within reach for test gauge hook up NPT tap must be upstream from heater see Figure 14 IMPORTANT Install equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance C...

Страница 12: ...t all leaks at once WARNING Never use an open flame to check for a leak Apply a noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once CAUTION Make sure external regulator has been installed between propane LP supply and fireplace See guidelines under Connecting to Gas Supply page 11 PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressures In Excess O...

Страница 13: ...ocedures WARNING Do not connect this thermostat to any electrical source Electrical shock and or fire hazard will occur 1 Disconnect jumper wire from control valve see Figure 19 page 14 2 Connect one terminal of 25 ft wire to TPTH terminal on control valve see Figure 19 page 14 3 Connect remaining wire terminal to the TH terminal on the control valve Make sure that wire terminals are in the positi...

Страница 14: ...re terminals are in the positions on your unit as pictured in Figure 19 If wires are not crossed the thermostat will not work 3 Route the 25 ft wire to a convenient location to mount your wall switch no outside walls WARNING Do not connect the switch to a power source Electrical shock and or fire hazard will occur IMPORTANT The wire may be shortened but must not be lengthened 4 Connect one bare wi...

Страница 15: ...smell This will only last a few hours WARNING Burnerwillcomeonautomaticallywithin one minute when control valve is in the ON position after the pilot is lit 1 STOP Read the safety information in column 1 2 Make sure equipment shutoff valve is fully open 3 Press in and turn control knob clockwise to the OFF position see Figure 23 4 Wait five 5 minutes to clear out any gas Then smell for gas includi...

Страница 16: ... See Lighting Instruc tions on page 15 After lighting let pilot flame burn for about one minute Turn control knob to ON position Slide the remote selector switch to the REMOTE position see Figure 26 Note The burner may light if hand held remote was on when the remote selector switch was last turned off You can now turn the burner on and off with the hand held remote control unit IMPORTANT Do not l...

Страница 17: ... FLAME PATTERN Figure 29 shows a correct burner flame pattern Figure 30 shows an incorrect burner flame pattern The incorrect burner flame pattern shows sporadic irregular flame tipping The flame should not be dark or have an orange reddish tinge Note When using the fireplace the first time the flame will be orange for approximately one hour until the log cures If burner flame pattern is incorrect...

Страница 18: ...PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner pilot and primary air inlet holes on injector h...

Страница 19: ...mote Ready Models Only 4 Burners will not come on in remote position Remote Ready Models Only REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 3 Replace ignitor cable 4 Replace ignitor 5 Replace pilot assembly 6 Replace pilot assembly 7 Install new alkaline battery in electronic ig nitor Verify battery is installed correctly 1 Turn on g...

Страница 20: ...ax carpet cleaners etc may turn into white powder residue 1 Not enough combustion ventilation air REMEDY 1 Contact local natural or propane LP gas com pany 2 Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 1 Clean burner see Cleaning and Maintenance page 18 or replace burner orifice 2 Replace damaged burner 3 Replace gas regulator 4 Contact local natural or propane LP g...

Страница 21: ... Low line pressure 3 ODS pilot is partially clogged 1 Gasleak SeeWarningstatementattopofpage 2 Control valve defective 1 Foreign matter between control valve and burner 2 Gasleak SeeWarningstatementattopofpage REMEDY 1 Replacebatteriesinreceiverandremotecontrol 1 This is normal with most fireplaces If noise is excessive contact qualified service person 1 Open window to ventilate room Stop using od...

Страница 22: ...re is too low If so contact your local gas supplier TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting Please contact your IHP dealer for any questions or concerns When contacting your dealer please have your model and serial numbers of your fireplace ready You can also visit our web site at Astria US com REPLACEMENT PARTS See Pages 24 to 25 for a comp...

Страница 23: ...SCREEN THERMOSTAT REMOTE CONTROL KIT For all models Allows gas log heater to be operated in a manually thermostatically or programmed controlled mode MODE SET PROG F1079 TSRC Receiver and Touch Screen Remote Control Kit RECEIVER AND HAND HELD THERMOSTAT REMOTE CONTROL KIT For all Remote Ready Models Allows the fireplace to be operated in a manually or thermostatically controlled mode You can turn ...

Страница 24: ...REMOTE READY MODELS ZETA21ZMN AND ZETA21ZMP 1 2 34 33 31 33 3 39 4 32 15 16 33 33 33 27 30 14 28 29 26 33 38 25 24 36 40 5 22 40 15 16 19 34 20 41 18 23 17 21 6 7 35 9 34 11 13 10 37 12 8 AAA Battery Negative UP Install Battery According To This Illustration ...

Страница 25: ...8264 03 Connector 3 8 MPT x 1 2 Flare 1 22 119318 01 Outlet Tube 1 120078 02 Outlet Tube 1 23 101628 04 Flexible Connector 1 24 118606 01 Ignitor Bracket 1 25 111435 01 Electronic Ignitor 1 26 098271 12 Ignitor Cable 1 27 103778 01 ODS Pilot Propane LP Gas 1 112376 01 ODS Pilot Natural Gas 1 28 119425 01 Injector LP 1 119425 02 Injector NG 1 29 099387 18 Pilot Tube 1 30 112881 03 Pilot Shield 1 31...

Страница 26: ..._____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________...

Страница 27: ...dent riot fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce exc...

Страница 28: ...ons pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126885 01 Rev B 04 2015 1508 Elm Hill Pike Suite 108 Nashville TN 37210 Model Number Serial Number Date Installed Dealer s Name Dealer s Phone Number Keep receipt for warranty verification P126885 01 ...

Отзывы: