       WARNING

 

The fi replace cannot be operated without a door 
or fi rescreen.  Consult your dealer to select the 
correct door or fi rescreen.

 

Important! To assure proper alignment of glass 
doors: Install this fi replace in a square and 
plumb condition, using shims as necessary at 
sides and/or bottom.

 

Install the fi replace only as described in these 
instructions.

Listed to standards:

ULC-S610 & UL-127

Report #   14-197

EPA Cert. No. 518

     

WARNING

 

Hot! Do not touch!  The glass and 
surfaces of this appliance will be hot 
during operation and will retain heat 
for a while after shutting off the appli-
ance.  Severe burns may result. 

• 

 

Carefully supervise children in the 
same room as appliance.

 

If small children are present in the home, it is 
recommended that this appliance be fi tted with 
an adjustable safety gate or barrier screen.

A French manual is available upon request. Order P/N 900136-00.

Ce manuel d’installation est disponible en francais, simplement en faire 
la demande. Numéro de la pièce 900136-00.

Wood Burning Fireplaces
P/N  900135-00  REV. B  06/2016

 Villa 

Vista 

 

VILLA VISTA™

This installation manual will enable you to obtain a safe, effi cient and 
dependable installation of your fi replace system. Please read and 
understand these instructions before beginning your installation.

Do not alter or modify the fi replace or its components under any circum-
stances. Any modifi cation or alteration of the fi replace system, including 
but not limited to the fi replace, chimney components and accessories, 
may void the warranty, listings and approvals of this system and could 
result in an unsafe and potentially dangerous installation.

IHP wood-burning fi replaces are designed for use as a supplemental 
heater.   They are not intended for continuous use as a primary heat 
source.

INSTALLATION AND 
OPERATION INSTRUCTIONS

P900135-00

C

US

Содержание VILLA VISTA

Страница 1: ...justable safety gate or barrier screen A French manual is available upon request Order P N 900136 00 Ce manuel d installation est disponible en francais simplement en faire la demande Num ro de la pi...

Страница 2: ...uctionconditions inadequate chimney heights adverse wind conditions and or unusualenvironmentalfactorsor conditions beyond our control WARNING The Villa Vista fireplace must be installed with an outsi...

Страница 3: ...ACBI Chimney Installation Instructions Page 19 Offset Chimney Installation Page 20 Angled Wall Radiation Shield Page 21 Chimney Support Installation Page 22 Chimney Chase And Multiple Terminations Pa...

Страница 4: ...ng the combustor have to be higher than 500 F 260 C That is why the unit is equipped with a by pass damper that allows the draft air to by pass the catalytic combustor Opening the by pass damper contr...

Страница 5: ...ndonmanyfactors includingchimney length and the moisture content of the wood This method of burning should be used only after operating the Villa Vista fireplace with the aircontrolopenedtoproduceahot...

Страница 6: ...including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes It is against federal regulations to operate wood heaters in a man...

Страница 7: ...roper operation will prevent chimneyfires Keepyourchimneyclean Donot allow more than 1 16 creosote build up in your chimney The amount of creosote will depend on variables such as frequency of use and...

Страница 8: ...after a hot fire has been started Burn hardwoods Masking Soot See Photo 8 Combustor has not maintained a light off Burning coal will cause a sulfur based compound to coat the catalyst Place combustor...

Страница 9: ...e Do not use abrasives such as steel wool or steel pads for they may scratch the door frame finish Ashes Whenever ashes get 3 to 4 inches deep in your firebox andwhenthefirehasburneddownand cooled rem...

Страница 10: ...door using the hinge screws see Figure 9 Figure 8 HINGE SCREWS GASKET ADJUSTEMENT SCREW DOOR HINGE SCREWS Figure 9 DO NOT USE CHEMICAL GLASS CLEANERS ON PAINTED SURFACES AS IT MAY CAUSE THE PAINT TO P...

Страница 11: ...nts The Villa Vista fireplace may be installed directly on a combustible floor The supplied safety metal strip must be positioned as fol lows One half under the front of the fireplace and the other ha...

Страница 12: ...llustrations and photographs are nottoscale consultinstallationinstructions Product designs materials dimensions specifications colorsandpricesaresubjectto change or discontinuance without notice Allf...

Страница 13: ...bustibles around chimney components required NOTE Blown or fill type insulation materials must not be in contact with the fireplace or in theenclosureframeasdescribedin Enclosure section NOTE Localcod...

Страница 14: ...he unit 38 and a height of 54 from the base of the appliance see Figure 15 3 Non combustible materials such as brick stone or ceramic tile may project in front of and onto the fireplace facing see Fig...

Страница 15: ...mum length See Figure 17 The height of the louver must be measured from the base of the Villa Vista fireplace to the middle point of the louver When installing the double outlet system the hotairoutle...

Страница 16: ...ral heating system Malfunction of the heating system s fan will cause the furnace duct to overheat A furnace duct is only single wall and not double wall as is required for the Villa Vista fireplace h...

Страница 17: ...basement or garage 4 The air intake register should be installed where it is not likely to be blocked by snow or exposed to extreme wind and well away fromautomobileexhaustfumes gasmeters and other ve...

Страница 18: ...ity Chimneys International Ltd 7 diameter chimney systems models ACBI or ASHT or S2100 or DuraVent model DuraTech DTC chimney systems NOTE Use of ACBI chimney with these fireplaces require the use of...

Страница 19: ...stallauniversalsupportfasteningthestrapsto thesurroundingjoists ASHT Installsupport as required see Chimney Support Installation Section on Page 22 4 Puttheroofflashinginplaceandsealthejoint between t...

Страница 20: ...45mm 19 483mm 21 3 8 545mm CrossSlopeHoleSize Putthechimneycapintoplace Washtheroofflashingwithasolvent or vinegar thenpaintitwithrust proof paint Table 2 1 Install the first elbow Turn it in the requ...

Страница 21: ...TC 15 Deviation 3 5 16 84 mm 4 5 16 110 mm 5 7 8 149 mm 7 7 16 189 mm 10 1 2 268 mm 13 5 8 346 mm 15 3 8 391 mm 16 7 16 418 mm 18 457 mm 19 1 2 495 mm 22 5 8 575 mm Length 15 11 16 398 mm 19 9 16 497...

Страница 22: ...ightly lift the chim neysystemsotheweightwilllieonthesupport notonthefireplacetoreduceexpansionnoises This support has two possible uses 1 For ASHT it must be used on a roof to support the chimney 2 I...

Страница 23: ...SHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the masonry chimn...

Страница 24: ...r Chimney for Relining Masonry Chimneys Tubinox chimney or Projet SS 7 diameter with adaptor for installation in a masonry chimney NOTES Projet Nova Temp HT6000 is equivalent to S2100 Projet Nova Temp...

Страница 25: ...o flexible pipe adaptor BISAVF BISAVF Backdraft damper BISBD BISBD Fireplace to Flex adaptor and 2 clamps BISAF BISAF Thermopile gauge and label replacement J8004 CLEARANCE TO COMBUSTIBLES The followi...

Страница 26: ...orts Support Section 10 long ACBI7SL ACBI7SL Universal Support AC10SU AC10SU Roof Flashings 1 12 7 12 5 30 Adjustable ACBI7FAR ACBI7FAR 8 12 12 12 30 45 Adjustable ACBI7FBR ACBI7FBR Flat Roof Flashing...

Страница 27: ...r ordering information DuraTech DTC 1 High Temp Insulated Stainless Steel Chimney 7 I D and 11 O D Double Wall Stainl Steel Listed to CAN UCL S604 UL 103HT and CAN ULC S629 Description Part Cat No Len...

Страница 28: ...ney Adaptor 45 BISPMA CANADA ONLY BISPMA 30 Adaptor for Masonry Chimney BISPMA30 BISPMA30 SECURITY CHIMNEYS PARTS AND COMPONENTS LISTS The components listed below must be ordered from Security Chimney...

Страница 29: ...may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high ef ciency EPA replaces are approved for burning dry seasoned...

Страница 30: ...CEMENT PARTS See Page 25 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be...