PUREFIRE EMISSION CONTROL SYSTEM  

Continued

NOTE:

 Chimney smoke may be visible during the first 8 to 10 minutes 

of fireplace operation when the fire is first getting started and the 

final 8 to 10 minutes of operation while the fire is dissipating. Under 

normal operating conditions, you should see little or no smoke coming 

out of the chimney. If continuous smoke is visible, make sure only 

dry seasoned wood is being burned. If visible smoke continues, the 

combustor has ceased to function or there is thermal crumbling. Call 

your

 IHP distributor or dealer 

for replacement parts. 

MANUFACTURER:                                   INNOVATIVE HEARTH PRODUCTS, LLC

MODEL NO:                                             GEORGIAN CAT 50

 

    

    

PARTICLE EMISSIONS:                         4.4 GRAMS/KG OF WOOD BURNED

                                                             

FIREPLACE

 SMOKE EMISSIONS RANGE

Higher Emissions

Lower Emissions

0

12.0

THIS MODEL

EPA PHASE 2 EMISSIONS LEVEL

4.4

5.1

Better

Worse

U.S. Environmental Protection Agency 

Wood-burning Fireplace Program

Phase 2 Qualified models are cleaner and pollute less than those models that 
have not met this emissions level. Exposure to smoke has been associated with 
respiratory illness and other health problems. Models that have lower smoke 
emissions may reduce your risk.

PHASE 2 QUALIFIED

For more information go to www.epa.gov/burnwise

Fireplaces with lower emissions produce less smoke when installed and operated properly.

* EPA has determined, based on testing by an accredited independent laboratory and a certification

of conformity by a nationally recognized certification body, that this model qualifies at the Phase 2 

emissions level for U.S. EPA's Voluntary Fireplace Program. 

For proper operation, catalyst must be replaced every 3 to 5 years.

127095-01

For more information go to 

www.epa.gov/burnwise

U.S. Environmental Protection Agency 

Wood-burning Fireplace Program

Phase 2 Qualified models are cleaner and pollute less than those models that
have not met this emissions level. Exposure to smoke has been associated with
respiratory illness and other health problems. Models that have lower smoke
emissions may reduce your risk.

MANUFACTURER:  

INNOVATIVE HEARTH PRODUCTS, LLC

MODEL NAME:   

GEORGIAN CAT 42

   

PARTICLE EMISSIONS: 

4.4 GRAMS/KG OF WOOD BURNED

*EPA has determined, based on testing by an accredited independent laboratory and a certification 

of conformity by a nation ally recognized certification body, that this model qualifies at the Phase 2 

emissions level for U.S. EPA’s Voluntary Fireplace Program.

Better

Worse

FIREPLACE

 SMOKE EMISSIONS RANGE

Higher Emissions

Lower Emissions

0

12.0

THIS MODEL

EPA PHASE 2 EMISSIONS LEVEL

4.4

5.1

Better

Worse

Fireplaces with lower emissions produce less smoke when installed and operated properly.

127094-01

WARRANTY

INNOVATIVE HEARTH PRODUCTS (IHP) warranty obliga

-

tions for the PureFire Emissions Control System are limited 

to the terms set forth below. 

IHP warrants to the consumer who purchases a new solid 

fuel  burning  fireplace  containing  a  PureFire  Emissions 

Control System as a new component, to replace the catalyst 

at no charge should it cease to function within three years 

from  the  date  of  purchase.  The  PureFire  Catalytic  Com

-

ponent is designed to perform efficiently for three years 

of  fireplace operation.  ONLY  recommended fuels should 

be burned. Follow the fueling directions in manufacturers 

operation manual. For warranty purposes, proof of fireplace 

purchases is required. Labor for removal and/or installation 

of the catalytic component is not the responsibility of the 

manufacturer. 

Neither IHP nor the dealer who sells the PureFire Emissions 

Control System is responsible for indirect, incidental, spe

-

cial, punitive or consequential damages arising out of the 

improper use of this product or the continued use of this 

product beyond the required replacement period.

TECHNICAL SERVICE

You  may  have  further  questions  about  installation,  operation,  or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns a. When contacting your dealer please have your model 

and serial numbers of your fireplace ready. You can also visit our 
web site at Astria.US.com.

REPLACEMENT PARTS

See Pages 20 TO 22 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.

Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:

1. The model number of the fireplace.

2. The serial number of the fireplace.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the fireplace.

If you encounter any problems or have any questions concerning the 

installation or application of this fireplace, please contact your dealer.

IHP

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210

Visit us at Astria.US.com

Содержание Georgian Cat 42

Страница 1: ...d FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CA...

Страница 2: ...s in the vicinity of this or any other appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Do not place clothing or other flammable...

Страница 3: ...s and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poisoning Ea...

Страница 4: ...Continued 42 MODEL 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17 5 8 67 61 49 7 1 30 11 58 42 51 1 8 4 1 2 3 1 2 9 1 2 10 1 2 81 2 13 17 OUTSIDE AIR ACCESS GAS LINE ACCESS 42 HEARTH 1 1 4 23 Ref 41 3 8 26 3 8...

Страница 5: ...IONS Continued 50 MODEL Figure 2 50 Model Georgian Cat 50 38 1 2 28 1 2 43 8 17 5 8 19 1 4 24 49 30 11 61 67 58 7 1 59 50 4 1 2 3 1 2 9 1 2 10 1 2 8 1 2 13 17 GAS LINE ACCESS OUTSIDE AIR ACCESS 50 HEA...

Страница 6: ...s and height of termination assembly at level of the flue gas outlet see Figure 14 page 10 FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 3 and 4 2 If fireplace is to be insta...

Страница 7: ...rial see Figure 5 WARNING Hearth extension is to be installed only as shown in Figure 5 Figure 5 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front...

Страница 8: ...e Section 34 5 8 48 12DM 48 12HT Pipe Section 46 5 8 RLT 12D RLT 12HT Round Termina tion 7 3 4 STL 12D Square Chase Top with Slip Section 7 to 15 The lineal gain for the terminations is measured to th...

Страница 9: ...tions of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 9 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to rafters or joists see Figure...

Страница 10: ...restopspacersarerequiredateachpointwherethechimneypenetrates a floor space Their purpose is to establish and maintain the required clearancebetweenthechimneyandthecombustiblematerials Whenthe pipepass...

Страница 11: ...5 Min 30 Min 2 Min 2 Min 2 Min Opening A Figure 14 Roof Opening Measurements Nail Only Outer Perimeter of Flashing Storm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles Top and Sides...

Страница 12: ...re to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stacked at a v...

Страница 13: ...ING OR LIFTING Figure 20 Installing Hearth and Leading Brick panels Hearth Panel Side leading brick Panel 3 Install the left and right firebrick walls There is a bracket with 2 tabs on the bottom of e...

Страница 14: ...e 5 Grout all joints where two firebrick walls come together 6 Using a trowel remove excess grout mixture by moving trowel in the direction of the joint Grout mixture in the joint should now be flush...

Страница 15: ...hook up should be done by your supplier or a qualified service person Note Before you proceed make sure your gas supply is turned off Use only a 1 2 black iron pipe and appropriate fittings 1 Remove...

Страница 16: ...requirements for Gas Fired Log Lighters for Wood Burning Fireplaces Draft NO 4 dated August 1993 If you install a decorative gas appliance vented gas log the deco rative gas appliance must comply wit...

Страница 17: ...igure 31 Installing Bottom Door Frame and Air Deflector Hex Screw Bottom Door Frame Ash Lip Ash Lip Air Deflector OPERATION AND MAINTENANCE GUIDELINES GLASS DOORS Glassdoorsareoptionalwiththefireplace...

Страница 18: ...re building technique and ash removal procedures These fueling guidelines must be fol lowed in order to achieve maximum emissions performance from the PureFire System OPERATION The proper use of a woo...

Страница 19: ...ally recognized certification body that this model qualifies at the Phase 2 emissions level for U S EPA s Voluntary Fireplace Program Better Worse FIREPLACE SMOKE EMISSIONS RANGE Higher Emissions Low...

Страница 20: ...Astria US com 126640 01D 20 PARTS MODELS 42 AND 50 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Страница 21: ...4369 Conduit Two 2 18 Heat Shield Support 1 19 J6020 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 J4341 Screen 42 2 J4340 Screen 50 2 24 J4391 Screen Ro...

Страница 22: ...included for convenience CATALOG NO MODEL NO DESCRIPTION F0366 Estate42P2 Stacked Rust F1367 Estate42P2 Stacked Cappuccino F0368 Estate42P2 Stacked Creamer F0369 Estate42P2 Stacked Gray F0370 Estate42...

Страница 23: ...Wall Pipe Snap Lock F0933 18 12DM 18 Section Double Wall Pipe Snap Lock F0934 24 12DM 24 Section Double Wall Pipe Snap Lock F0935 36 12DM 36 Section Double Wall Pipe Snap Lock F0936 48 12DM 48 Section...

Страница 24: ...2D Round Top Termination with Louvered Screen F0960 RLT 12HT Hi Temp Round Top Termination with Louvered Screen FIRESTOP THIMBLE F0944 FST10 Firestop Thimble LABEL UL127 50PK WARNING HOT Fire Risk Ins...

Страница 25: ...ey Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel deliver...

Страница 26: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Страница 27: ...sing a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burni...

Страница 28: ...lso to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 126640 01 Rev D 10 2015 P126640 01 1508 Elm Hill Pike Suit...

Отзывы: