FIREPLACE INSTALLATION 

Continued

Figure 3 - Hearth Extension

 WARNING: Hearth extension is to be installed 

only as shown in Figure 3.

FIREBOX

SAFE ZONE

Figure 6 - Side Mantel Clearance

Top View of Fireplace

Min. 12" from 

Perpendicular Side Wall

3"

2" Max.

33°

8"

MANTELS

A mantel may be installed if desired (see Figures 4 and 5). Woodwork 

such as wood trims, mantels or any other combustible material 

projecting from front face, must not be placed within 12" of fireplace 

opening and within 9" of top louver opening. Combustible materials 

above 12" and projecting more than 1 1/2" from fireplace must not 

be placed less than 12" from top opening of fireplace (NFPA 211, 

Section - Clearance from Combustible Material).

Mantels or any other combustible material may come up to side edge 

of black metal face of fireplace if projection from front face falls within 

limits shown in Figure 6.

Figure 4 - Mantel Clearances to Combustible Material (with 

Louver)

Figure 5 - Mantel Clearances to Combustible Material (without 

Louver)

12 

1

/

4

" Ref.

1

/

2

"

Max.

Upper Section

of Circulating

Fireplace

6"

Ref.

9"

Min.

33°

3" Nom.

*Note

: Drawing Not To Scale

Safe Zone For

Projection of

Combustible

Materials

Combustible

Material

Non Combustible

Materials Below 

Top Spacer

15"

Min.

12"

Min.

Fireplace Opening

Top of 

Louvered

Opening

12 

1

/

4

" Ref.

6"

Ref.

15" Min.

12" Min.

1

1

/

2

" Max.

3" Nom.

33°

Combustible 

Material

Safe 

Zone for 

Projection of 

Combustible 

Materials

Fireplace Opening

Top 

Spacer

Upper 

Section of 

Fireplace

Fireplace Front

Fireplace Front 

Raised Hearth

Fireplace Front 

Elevated

Seal Gap

Seal Gap

Seal Gap

Seal Gap

Fireplace Front

Ember Protector

Fireplace Front 

Elevated

Do Not Block Louver

Ember Protector

Ember Protector

Ember Protector

Ember Protector

Hearth 

Extension

Hearth 

Extension

Hearth Extension, Circulating Models

Hearth Extension, Noncirculating Models

NO

Содержание Craftsman 42P2

Страница 1: ...wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODU...

Страница 2: ...e voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufac...

Страница 3: ...insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poiso...

Страница 4: ...TIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE R...

Страница 5: ...ace directly in front of this opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prep...

Страница 6: ...ce if projection from front face falls within limits shown in Figure 6 Figure 4 Mantel Clearances to Combustible Material with Louver Figure 5 Mantel Clearances to Combustible Material without Louver...

Страница 7: ...ower Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1...

Страница 8: ...ELBOW OFFSET 30E 12DMO 8DMR To clear overhead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets a...

Страница 9: ...e Detail B Ceiling Support Pipe 12S 8DM 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offse...

Страница 10: ...with Living Space Above Ceiling If area above is a living space install firestop below framed hole Figure 12 Elbow Offset OFFSET CHART WITH TRANSITION PIPE OFFSET RISE OFFSET RETURN ELBOW TRANSITION...

Страница 11: ...Attic Space Above Ceiling If area above is an attic or insulated area install firestop above framed hole IMPORTANT NOTICE When penetrating a ceiling into an attic a firestop thimble 38FST or FST30 is...

Страница 12: ...l use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 17 Use SC1 for all roun...

Страница 13: ...duit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figure 23...

Страница 14: ...ARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qual...

Страница 15: ...of place while fireplace was in transit These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 26 For further operating guidelines instructions and warranty informa tion ple...

Страница 16: ...tria US com 126662 01D 16 PARTS WOOD BURNING FIREPLACE MODELS Craftsman 42P2 Craftsman 42P3 9 12 25 20 30 17 8 1 5 21 2 34 18 11 14 3 37 13 22 10 6 31 7 38 36 35 28 29 15 27 26 16 16 27 4 32 33 19 23...

Страница 17: ...ractory 1 12 See Page 18 Bottom Rear Refractory 1 13 See Page 18 Bottom Front Refractory 1 14 Firebox Support Leg 4 15 106687 02 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1...

Страница 18: ...hed Brass BD42P Platinum FAN KIT BK3 30 OFFSET AND RETURN 30E 8DM 30E 8HT 30E 12DMO 8DMR F1908 30E 12HTO 8HTR F2199 HERRINGBONE BRICK LINER WHITE Craftsman 42P3 F0713 F0716 Left 108169 01 Right 108170...

Страница 19: ...8DM MESH SQUARE TOP TERMINATION WITH SLIP SECTION ETLO 8DM OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F MESH ROUND TOP TERMINATIONS RT 8DM TR 8HT RTL 8DM AND RTL 8HT 1 FIRESTOP SPACER 3600FS 8DM 1 OUTS...

Страница 20: ...n design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126662 01 Rev D 10...

Отзывы: