Astria Craftsman 42P2 Скачать руководство пользователя страница 14

Astria.US.com

126662-01D

14

Figure 24 - Glass Doors

OPERATION AND MAINTENANCE

Doors Fully Closed

Doors Fully Opened

Fireplace Front

Fireplace Front

GLASS DOORS

Glass  doors  are  optional  with  this  fireplace.  When  fireplace  is  in 

operation, doors must be fully opened or fully closed position only 

or a fire hazard may be created (see Figure 24).

A fireplace equipped with glass doors operates much differently than 

a fireplace with an open front. A fireplace with glass doors has a 

limited amount of air for combustion. Excessive heat within fireplace 

can result if too large a fire is built or if combustion air gate is not 

completely open.
The following tips should be used to assure that both fireplace and 

glass door retain their beauty and function properly. Both the flue 

damper and glass doors must be fully opened before starting a 

fire. This will provide sufficient combustion air and maintain safe 

temperatures in firebox.

IMPORTANT: 

The glass must be allowed to warm slowly and evenly. 

Tempered glass will withstand a gradual temperature rise to 550° 

F, which is more than a normal fire will generate. Such materials as 

pitch/wax laden logs, very dry mill end lumber and large amounts 

of paper or cardboard boxes can create an excessively hot fire and 

should not be burned in this fireplace. Always keep fire back from 

doors and never allow flames to contact glass.

 " WARNING: FIREPLACES EQUIPPED WITH DOORS 

SHOULD BE OPERATED ONLY WITH DOORS FULLY 

OPEN OR DOORS FULLY CLOSED. IF DOORS ARE LEFT 

PARTLY OPEN, GAS AND FLAME MAY BE DRAWN OUT 

OF THE FIREPLACE OPENING, CREATING RISKS OF 

BOTH FIRE AND SMOKE".

WARNING: Discontinue use of the appliance imme-

diately if doors are damaged and contact a qualified 

installer for repair. Only doors certified with the 

appliance shall be used.

 WARNING: Do not slam or strike doors. Damage 

can result in a hazardous condition.

Figure 23 - Gas Line Installation

Figure 22 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded End for 

Fitting Connection

If you install a decorative gas appliance (vented gas log), decorative 

gas appliance must comply with the Standard for Decorative Gas 

Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI 

Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance 

with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/

CGA-B149.1 National Gas And Propane Installation Code (Canada).

 

WARNING: To avoid the risk of damaging fireplace 

materials and increasing the risk of spreading a fire, 

do not use fireplace to cook or warm food.

 WARNING: If the fireplace has been used for wood 

burning, firebox and chimney must be cleaned of soot, 

creosote and ashes be a qualified chimney cleaner. 

Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas 

log, damper must be removed or permanently locked 

in fully open position and glass doors must be in fully 

open position.

OPTIONAL GAS LINE INSTALLATION 

Continued

Содержание Craftsman 42P2

Страница 1: ...wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HEARTH PRODU...

Страница 2: ...e voided by and IHP disclaims any respon sibility for the following actions a Modification of the fireplace components doors air inlet system and damper control b Use of any component part not manufac...

Страница 3: ...insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxide Poiso...

Страница 4: ...TIBLE MATERIAL ON FACE NO COMBUSTIBLE MATERIAL BELOW TOP SPACERS GAS LINE KNOCK OUT AIR KIT KNOCK OUTS GAS LINE STARTER SECTION 8DM PIPE INNER DIA OUTER DIA 15 KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE R...

Страница 5: ...ace directly in front of this opening and slide unit back until nailing flanges touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prep...

Страница 6: ...ce if projection from front face falls within limits shown in Figure 6 Figure 4 Mantel Clearances to Combustible Material with Louver Figure 5 Mantel Clearances to Combustible Material without Louver...

Страница 7: ...ower Source Receptacle Supplied Power Source Wiring Not Supplied Prewired Receptacle and Ground Sheet Metal Screws Figure 8 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1...

Страница 8: ...ELBOW OFFSET 30E 12DMO 8DMR To clear overhead obstructions you may offset your chimney system using 30E 12DMO 8DMR 30 Offset return elbow A section or sections of chimney may be used between offsets a...

Страница 9: ...e Detail B Ceiling Support Pipe 12S 8DM 30E 8DM Return Elbow 30E 8DM Return Elbow 30E 8DM Offset Elbow 30E 8DM Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offset Elbow 30E 12DMO 8DMR Offse...

Страница 10: ...with Living Space Above Ceiling If area above is a living space install firestop below framed hole Figure 12 Elbow Offset OFFSET CHART WITH TRANSITION PIPE OFFSET RISE OFFSET RETURN ELBOW TRANSITION...

Страница 11: ...Attic Space Above Ceiling If area above is an attic or insulated area install firestop above framed hole IMPORTANT NOTICE When penetrating a ceiling into an attic a firestop thimble 38FST or FST30 is...

Страница 12: ...l use only noncombustible mortar or adhesive Storm Collar Installation SC1 Place storm collar over pipe and slide down until it is snug against open edge of flashing see Figure 17 Use SC1 for all roun...

Страница 13: ...duit sleeve if using a raised platform add height Provide sufficient gas line into fireplace chamber for fitting OPTIONAL GAS LINE INSTALLATION VENTING INSTALLATION Continued connection see Figure 23...

Страница 14: ...ARELEFT PARTLYOPEN GASANDFLAMEMAYBEDRAWNOUT OF THE FIREPLACE OPENING CREATING RISKS OF BOTH FIRE AND SMOKE WARNING Discontinue use of the appliance imme diately if doors are damaged and contact a qual...

Страница 15: ...of place while fireplace was in transit These coverplatesmustbekeptintheproperlocationpriortousingthefireplace See Figure 26 For further operating guidelines instructions and warranty informa tion ple...

Страница 16: ...tria US com 126662 01D 16 PARTS WOOD BURNING FIREPLACE MODELS Craftsman 42P2 Craftsman 42P3 9 12 25 20 30 17 8 1 5 21 2 34 18 11 14 3 37 13 22 10 6 31 7 38 36 35 28 29 15 27 26 16 16 27 4 32 33 19 23...

Страница 17: ...ractory 1 12 See Page 18 Bottom Rear Refractory 1 13 See Page 18 Bottom Front Refractory 1 14 Firebox Support Leg 4 15 106687 02 Damper Can Collar 1 16 107839 01 Screen Rod 2 17 Firebox Top Assembly 1...

Страница 18: ...hed Brass BD42P Platinum FAN KIT BK3 30 OFFSET AND RETURN 30E 8DM 30E 8HT 30E 12DMO 8DMR F1908 30E 12HTO 8HTR F2199 HERRINGBONE BRICK LINER WHITE Craftsman 42P3 F0713 F0716 Left 108169 01 Right 108170...

Страница 19: ...8DM MESH SQUARE TOP TERMINATION WITH SLIP SECTION ETLO 8DM OUTSIDE AIR KIT FOR FLOOR INSTALLATION AK4F MESH ROUND TOP TERMINATIONS RT 8DM TR 8HT RTL 8DM AND RTL 8HT 1 FIRESTOP SPACER 3600FS 8DM 1 OUTS...

Страница 20: ...n design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126662 01 Rev D 10...

Отзывы: