VENTING INSTALLATION

NOTICE: Read these instructions completely before 

attempting installation.

These models are tested and approved for use with an IHP (direct- 

vent) pipe components and terminations.
The venting system must terminate on the outside of the structure and 

can not be attached to a chimney or flue system serving a separate 

solid fuel or gas burning appliance. A direct-vent appliance must 

have its own venting system. DO NOT common vent this appliance.
These models are approved to be vented either horizontally through 

an outside wall or vertically through a roof or chase enclosure using 

the following guidelines:
•  When venting system terminates horizontally on an outside wall, 

you may install a standoff if the termination cap is to be installed 

directly on a combustible finish such as vinyl, wood, stucco, etc.

•  Never run the vent downward as this may cause excessive tem-

peratures which could cause a fire.

•  Vent pipe air space clearances to combustibles are 1" on all sides 

except on the horizontal sections, which requires 2" clearance 

from the top of the pipe. Where the termination cap penetrates a 

combustible wall, 1" air space clearance is required.

•  Have fireplace and selected vent components on hand to help 

determine the exact measurements when elbowing or offsetting. 

Always use wall firestops when penetrating walls and firestops 

when penetrating ceilings or attic spaces.

•  For installation of fireplace at elevations of 4000 feet or greater, 

pay special attention to venting requirement recommendations.

 WARNING: Read all instructions completely and 

thoroughly before attempting installation. Failure to 

do so could result in serious injury, property damage 

or loss of life.

NOTICE: Failure to follow these instructions will void the 

warranty.

NOTICE: Do not seal termination cap to vent pipe. Cap 

must be removable for vent inspection and mainte-

nance.

INSTALLATION PRECAUTIONS

•  Wear gloves and safety glasses for protection
•  Use extreme caution when using ladders or when on roof tops
•  Be aware of electrical wiring locations in walls and ceilings
The following actions will void the warranty on your venting system:
•  Installation of any damaged venting component
•  Unauthorized modification of the venting system (Do not cut or alter 

vent components)

•  Installation of any component part not manufactured or approved 

by IHP

•  Installation other than as instructed by these instructions

 WARNING: This gas fireplace and vent assembly 

must be vented directly to the outside. The venting 

system must NEVER be attached to a chimney serving 

a separate solid fuel burning appliance. Each direct-

vent gas appliance must use a separate vent system. 

Do not use common vent systems.

 WARNING: Vent pipe air space clearances to com-

bustibles are 1" on all sides except on the horizontal 

sections, which require 2" clearances from the top 

of the pipe. Where the termination cap penetrates a 

combustible wall, 1" air space clearance is required.

INSTALLATION PLANNING

There are two basic types of direct-vent installation:
•  Horizontal Termination
•  Vertical Termination 
Horizontal Termination Installation

IMPORTANT:

 Horizontal square terminations require only inner por-

tion of wall firestop. Horizontal installations using round termination 

require exterior portion of wall firestop.
1.  Set fireplace in its desired location and determine the route your 

horizontal venting will take. Do not secure fireplace until all venting 

has been installed. Some installations require sliding fireplace in 

and out of position to make final venting connections. 

Figures 

15 and 16 on Pages 12 and 13

, show different configurations 

for venting with horizontal termination that will help you decide 

which application best suits your installation. Check to see if wall 

studs or roof rafters are in the path of your desired venting route. 

If they are, you may want to adjust location of fireplace.

2.  Direct-vent pipe sections and components are designed with 

special twist-lock connections.

 

Twist-Lock Procedure:

 Female ends of pipes have locking lugs 

(indentations). These lugs will slide straight into matching slots 

on male ends of adjacent pipes. Push pipe sections together and 

twist one section clockwise approximately one-quarter turn until 

sections are fully locked 

(see 

Figure 9, Page 13

)

.

 

NOTE: 

Horizontal runs of vent must be supported every three feet. 

Use wall straps for this purpose.

3.  Assemble desired combination of pipe and elbows to fireplace flue 

collar. If there are long portions of venting run, pre-assembled 

pipe sections may be installed as subassemblies for convenience.

4.  Carefully determine location where vent pipe assembly will penetrate 

outside wall. Center of hole should line up with center line of horizontal 

vent pipe. Mark wall for an 11-1/2" x 11-1/2"  square hole. Cut and 

frame square hole in exterior wall where vent will be terminated. If 

wall being penetrated is constructed of noncombustible material, such 

as masonry block or concrete, an 8-1/2" hole with zero clearance is 

acceptable 

(see 

Figure 10, Page 13

).

 WARNING: Do not recess vent termination into any 

wall. This will cause a fire hazard.

f i r e - p a r t s . c o m

Содержание Sentinel 36TEN

Страница 1: ...out autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Netouchezàaucaninterrupteur Nepasvousservir des téléphones se trouvant dans le bâtiment où vous trouvez Sortez immédiatement de bâtiment Appelez immédiatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le ser...

Страница 2: ...NCA TOCAR EL VIDRIO CALIENTE LOS NIÑOS DEBEN NUNCA TOCAR EL VIDRIO L écran pare étincelles fourni avec ce foyer réduit le risque de brûlure en cas de contact accidentel avec la vitre chaude et doit être installé pour la protection Des enfants et Des personnes à risques Vea el volante adjunto para la representación de color adecuado See attached color flyer for proper color representation Voir ci j...

Страница 3: ...ents du danger de brûlure encouru Les surfaces de votre foyer deviennent EXTRÊMEMENT CHAUDES La vitre située à l avant du foyer atteint des températures EXTRÊMEMENT ÉLEVÉES et peut causer de graves blessures en cas de contact Tenez les enfants à l écart du foyer lorsqu il fonctionne Surveillez attentivement les enfants dans les pièces où un foyer est utilisé afin d éviter qu ils ne soient en conta...

Страница 4: ... vented gas fireplace is a sealed combustion gas fireplace de signed for residential applications This fireplace must be installed with INNOVATIVE HEARTH PRODUCTS IHP vent pipe components and terminations NOTICE Decorative product not for use as a heating appliance This fireplace must be installed by a qualified certified or licensed service person It brings in fresh air for combustion through the...

Страница 5: ...ontact avec la surface chaude Il est recommandé d installer une barrière physique si des personnes à risques habitent la maison Pour empêcher l accès à un foyer ou à un poêle installez une barrière de sécurité cette mesure empêchera les tout petits les jeunes enfants et toute autre personne à risque d avoir accès à la pièce et aux surfaces chaudes 7 Tout écran ou protecteur retiré pour per mettre ...

Страница 6: ...Continued Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be re quired due to excessive lint from carpeting bedding material etcetera It is imperative that control com partments burners andcirculatingairpassageways of the appliance be kept clean Childr...

Страница 7: ...to or under water Immediately call a qualified service person to arrange for replacement of the unit 10 Do not operate fireplace if any log is broken 11 Do not operate fireplace with glass door removed cracked or broken 12 Provide adequate clearances around air openings LOCAL CODES Install and use fireplace with care Follow all local codes In the absence to local codes use the current National Fue...

Страница 8: ...ile or any combustible material other than wood it must be installed on a metal or wood panel extending the full width and depth of the fireplace see Figure 3 Page 9 Your fireplace is designed to be used in zero clearance installations Wall or framing material can be placed directly against any exterior surface on back sides or top of your fireplace except where standoff spacersareintegrallyattach...

Страница 9: ... Model 35 889 mm 36 Model 42 1067 mm 42 Model 41 1041 mm 36 Model 48 1219 mm 42 Model 44 1118 mm 42 Model 40 1016 mm 36 Model 30 762 mm 36 Model 48 1219 mm 42 Model 24 610 mm 42 Model 13 5 8 346 mm 42 Model Requires IHP 5 127 mm I D 8 203 mm O D Direct Vent Pipe 2 1 4 57 mm 6 3 4 171 mm 10 3 4 273 mm 36 Model 11 1 2 292 mm 42 Model 2 1 4 57 mm GAS LINE KNOCK OUT NAILING FLANGE NAILING FLANGE ELECT...

Страница 10: ...l noncombustible mantels at any height above the fireplace NOTE Noncombustible mantels may discolor Ensure adequate accessibility clearances for servicing and proper operation Figure 5 Framing Clearances with Outside Air Flex Duct Figure 5a Framing Dimensions Figure 6 Framing Clearances for Corner Installation Figure 7 Clearances for Combustible Mantels C B A D E F G 3 2 1 4 5 6 7 Wall 36 3 8 924 ...

Страница 11: ... greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally L clearance above paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall extend a minimum o...

Страница 12: ...ce and vent assembly must be vented directly to the outside The venting system must NEVER be attached to a chimney serving a separate solid fuel burning appliance Each direct vent gas appliance must use a separate vent system Do not use common vent systems WARNING Vent pipe air space clearances to com bustibles are 1 on all sides except on the horizontal sections which require 2 clearances from th...

Страница 13: ...l with provided wood screws see Figure 12 Page 14 Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before connecting horizontal run to vent cap see Figure 13 Page 14 Carefully move fireplace with vent assembly attached toward wall and insert vent pipe into horizontal termination Pipe overlap should be...

Страница 14: ...g a venting configuration of only horizontal venting with no vertical run a 1 4 rise for every 12 of run toward the termination is required NOTICE Do not seal termination cap to vent pipe Cap must be removable for vent inspection and mainte nance WARNING Never run vent downward as this may cause excessive temperatures which could cause a fire Operation of improperly installed and maintained ventin...

Страница 15: ...uilding code requirements described in Figure 17a NOTE You must increase vent height for steep roof pitches Nearby trees adjoining rooflines steep pitched roofs and other similar factors may cause poor draft or down drafting in high winds Increasing vent height may solve this problem 7 Twist lock vent cap onto last section of vent pipe Venting with Two 90 Elbows Vertical V Horizontal H1 H2 feet me...

Страница 16: ...ireplace at an elevation above 4500 feet check with local authorities PARTS LIST FOR VENTING KITS AND COMPONENTS IHP 5 8 Pipe Vent Kits IMPORTANT NOTE The installation accessories shown in this section are part of the safety agency listing for the product models represented in this manual Cat No Part No Description J2209 P58 6 6 Section Double Wall Pipe Galvanized J2201 P58 12 12 Section Double Wa...

Страница 17: ...een 11 and 14 of W C pressure If you do not reduce incoming gas pressure fireplace regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 21 Pointing the vent down protects it from freezing rain or sleet CAUTION Use only new black iron or steel pipe Internally tinnedcoppertubingmaybeusedincertain areas Check your local codes Use pipe of 1 2 diam eter...

Страница 18: ...fireplace or using compressed air 4 Check all joints of gas supply piping system Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak Correct all leaks at once CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed 5 16 hex socket wrench or nut driver sealant resistant to propane LP gas not provided 1 Route flexible gas line provided by installer from equipment s...

Страница 19: ...nel securely in place For replacement part information see Replacement Parts Page 31 CAUTION Wear gloves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass WARNING A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed WARNING If fireplace has been ...

Страница 20: ... around base of burner Make sure burner ports are not covered see Figure 30 Page 21 4 Place ember flakes around front and sides of burner and on burner ports see Figure 31 Page 21 This will create the glowing ember appearance as the flame touches the ember flakes Do not block burner ports or pilot ports by overlapping ember flakes in one area It is not necessary to use all ember material provided ...

Страница 21: ... leak Apply noncorrosive leak detection fluid to joints Bubbles forming show a leak Correct leaks at once CAUTION The gas supply shall be shut off prior to disconnecting the electrical power if any before proceeding with this installation CAUTION Use gloves when removing the log set burner module from your firebox Some metal edges may be sharp Use caution with log sets as logs are fragile 1 Remove...

Страница 22: ...ower locate the learn button Figure 36 on the module Press and release the learn button There will be a beep sound from the module Then press any button on the remote transmitter Once the module s internal receiver accepts the transmitter code there will be a series of confirming beeps The remote system is ready for use BATTERY BACK UP This fireplace is equipped with a battery back up If the power...

Страница 23: ...pteur mural qui contrôle le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parlée dans la résidence du propriétaire En cas de doute collez l étiquette en anglais 2 Si une télécommande est utilisée pour contrôler le foyer nettoyez la soigneusement pour éliminer la poussière et les traces de graisse ou d huile Collez l étiquette sur le boîtier de la télé c...

Страница 24: ... logs will give off a paper burning smell Orange flame will also be present Open damper or window to vent smell This will only last a few hours 1 STOP Read the safety information in column 1 2 Turn off all electric power to fireplace 3 Turn safety shutoff switch to the OFF position 4 Remove center brick control cover 5 Turn equipment shutoff valve clockwise to the OFF position see Figure 37 Do not...

Страница 25: ...ola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared Figura B Seleccione el idioma que más se habla en la casa 2 Si se usa un control remoto para controlar la chimenea encuentre el transmisor y límpielo bien para quitar el polvo y aceite Pegue la etiqueta en...

Страница 26: ... on installation type and weather conditions If the vent configuration is installed incorrectly flames will lift or ghost This can be dangerous Inspect flames after installation to ensure proper installation and performance Figure 40 shows a typical flame pattern If burner flame pattern differs from that described turn fireplace off see To Turn Off Gas to Appliance Page 24 see Troubleshooting Page...

Страница 27: ...oves and safety glasses while handling or removing broken glass Do not remove if glass is hot Keep children and pets away from glass If glass has been broken carefully remove glass door see Remov ing Replacing Glass Door Page 19 Vacuum all glass pieces with a shop vacuum CAUTION Do not vacuum if pieces are hot Use only glass door replacement intended for this fireplace see Replacement Parts Page 3...

Страница 28: ...t inspect and clean any other possible obstructions 4 Contact your gas supplier to check pres sure 5 Have a qualified technician replace pilot line 6 Replace control valve Refer to Replace ment Parts Page 37 7 Check that main power is on and that all wire connections are made correctly to ignition model see Wiring Diagram Page 36 Check for 24 VAC at the secondary side of transformer If 24 VAC is p...

Страница 29: ...ame holes blocked 3 Improper venting or excessive blockage 4 Excessive amounts of embers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots Dark residue on logs or inside of fireplace REMEDY 1 Locate and correct all leaks see Checking Gas Connections Page 18 2 Replace control valve 1 Take apart gas tubing and remove foreign matter 2...

Страница 30: ...ite Brick Sentinel36TEN F1578 SENTINEL 36 Natural STK White Brick Sentinel36TEP F1579 SENTINEL 36 Propane HER White Brick Sentinel36TEP F1580 SENTINEL 36 Propane STK White Brick MODEL CATALOG NO DESCRIPTION Sentinel42TEN F1581 SENTINEL 42 Natural HER White Brick Sentinel42TEN F1582 SENTINEL 42 Natural STK White Brick Sentinel42TEP F1583 SENTINEL 42 Propane HER White Brick Sentinel42TEP F1584 SENTI...

Страница 31: ...Hearth Assembly 42 Propane LP 1 J7654 Hearth Assembly 36 NG High Altitude 1 J7655 Hearth Assembly 42 NG High Altitude 1 7 J7656 Grate 36 1 J7657 Grate 42 1 8 J7658 Door Latch 2 9 Firebox Leg 4 10 Firebox Bottom 1 11 J7659 Gasket 36 1 J7660 Gasket 42 1 12 J7661 Draft Diverter 1 13 Air Exchange 1 14 5 Gasket 1 15 5 Inner Connector 1 16 A E Insulation 1 17 Firebox Surround 1 18 Firebox Top 1 19 Relie...

Страница 32: ...tural HER White Brick Sentinel42TEN F1582 SENTINEL 42 Natural STK White Brick Sentinel42TEP F1583 SENTINEL 42 Propane HER White Brick Sentinel42TEP F1584 SENTINEL 42 Propane STK White Brick WARNING Failure to position the parts in accor dance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury AVERTISSEMENT Ris...

Страница 33: ...e 1 7 J7840 Pilot NG 1 J7841 Pilot Propane LP 1 8 Pilot Shield 1 9 J7696 Elbow Street 3 8 1 10 J7697 Front Orifice 47 NG 1 J7698 Front Orifice 56 Propane LP 1 J7699 Front Orifice 42 NG 1 J7698 Front Orifice 56 Propane LP 1 11 Base 1 12 J7700 Grommet SC 1 2 ID 1 1 16 OD 1 13 J7701 90 Brass Elbow 3 8 Tube x 3 8 NPT 3 14 J7720 Flextube Dormont 3 8 Dia x 11 1 15 J7723 Flextube Dormont 3 8 Dia x 24 1 1...

Страница 34: ... Natural STK White Brick Sentinel36TEP F1579 SENTINEL 36 Propane HER White Brick Sentinel36TEP F1580 SENTINEL 36 Propane STK White Brick MODEL CATALOG NO DESCRIPTION Sentinel42TEN F1581 SENTINEL 42 Natural HER White Brick Sentinel42TEN F1582 SENTINEL 42 Natural STK White Brick Sentinel42TEP F1583 SENTINEL 42 Propane HER White Brick Sentinel42TEP F1584 SENTINEL 42 Propane STK White Brick fire parts...

Страница 35: ...fractory Stacked 36 White 1 2 J7813 Left Refractory Herringbone 42 White 1 J7814 Left Refractory Herringbone 36 White 1 J7815 Left Refractory Stacked 42 White 1 J7816 Left Refractory Stacked 36 White 1 3 J7817 Right Refractory Herringbone 42 White 1 J7818 Right Refractory Herringbone 36 White 1 J7819 Right Refractory Stacked 42 White 1 J7820 Right Refractory Stacked 36 White 1 4 J7821 Left Front R...

Страница 36: ...Rating 41 000 Btu hr Gas Type Natural Gas Only Ignition Electronic Manifold Pressure 3 5 W C Minimum Inlet Supply Pressure 5 W C Maximum Inlet Supply Pressure 10 5 W C Front Orifice 42 Rear Orifice 44 SENTINEL36TEP Rating 31 000 Btu hr Gas Type Propane LP Gas Only Ignition Electronic Manifold Pressure 10 W C Minimum Inlet Supply Pressure 11 W C Maximum Inlet Supply Pressure 13 W C Front Orifice 56...

Страница 37: ... may feel your gas pressure is too low If so contact your local gas supplier ACCESSORIES Purchase these appliance accessories from your local dealer If they can not supply these accessories contact IHP at Astria us com for referral information You can also write to the address listed on the back Page of this manual Only kits supplied by IHP shall be used in the installation of this appliance Use o...

Страница 38: ..._____________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________________________________________...

Страница 39: ...ood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatur...

Страница 40: ...our local distributor for fireplace code information Printed in U S A 2014 Innovative Hearth Products P N 126733 01 Rev H 01 2019 1769 East Lawrence Street Russellville AL 35654 P126733 01 Astria us com Record the following important information about your fireplace Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name fire parts com ...

Отзывы: