background image

16

Printed in U.S.A. © 2019 Innovative Hearth Products           

P/N  900976-00  REV. A  06/2019

Innovative Hearth Products (IHP) reserves the right to make changes at any time, without 

notice, in design, materials, specifications, prices and the discontinuance of colors, styles 

and products. Consult your local distributor for fireplace code information.

1769 East Lawrence Street • Russellville, AL 35654

P900976-00

Содержание OrionLR32WH

Страница 1: ...2WS OrionLR36WS OrionLR42WS OrionLR32WH OrionLR36WH OrionLR42WH WARNING If the information in this manual is not followed exactly a fire or explosion may resultcausingpropertydamage personalinjury or loss of life FOR USE ONLY WITH A LISTED GAS FIRED UNVENTED DECORATIVE ROOM HEATER NOT TO EXCEED 40 000 BTU H DO NOT BUILD A WOOD FIRE WARNING IMPROPER INSTALLATION ADJUST MENT ALTERATION SERVICE OR MA...

Страница 2: ...alified service person The heater should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet ing bedding material etc It is important that control compart ments burners and circulating air passageways of the heater be kept clean Allow the heater to cool before servicing Always shut off any electrici...

Страница 3: ...rous installation These Built In Vent Free Fireboxes have been testedandapprovedasVentlessFireboxEnclo suresforGas FiredUnventedDecorativeRoom Heaters to ANSI Z21 91 CONGRATULATIONS In selecting this Astria Vent Free Gas Firebox you have chosen the finest and most dependable fireplace to be found anywhere A beautiful prestigious alternative to a wood burning fireplace Welcome to a family of Astria...

Страница 4: ...a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms com municating directly with the space in which t...

Страница 5: ... heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Not to Scale Figure 1 CAUTION Do not install in the vicinity where gasoline or other flammable liq uids may be stored The Vent Free firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this applian...

Страница 6: ...ture finish material for the mantels Clearances Ensure the minimum clearances shown in Figures 2 through 4 are maintained Left and right clearances are determined when facing the front of the firebox Follow these instructions carefully to ensure safe installation Failure to follow these requirements may create a fire hazard Combustible Side Clearances Clearances from the side of the firebox openin...

Страница 7: ...itdirectlyonacombustiblesurface The appliance should be mounted on a fully supported base extending the full width and depth of the unit The appliance may be located on or near conventional construction materials However if installed on combustible materials such as carpeting vinyl tile etc a metal or wood barrier covering the entire bottom surface must be used Combustible Mantel and Trim Clearanc...

Страница 8: ...osion over time DO NOT USE AN OPEN FLAME TO CHECK FOR LEAKS Leak Test Procedure Turn on gas supply and test for gas leaks using a gas leak test solution A Light the appliance refer to the lighting instructions label provided with gas logs B Brush all joints and connections with the gas leak detection solution If bubbles are formed or gas odor is detected turn the gas control knob off pilot on toth...

Страница 9: ...l covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by checking the top edge of the firebox Shim if necessary Step 3 Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face Use 8d na...

Страница 10: ... ORIONLR42WS 42 1067 27 7 8 708 47 3 4 1213 37 1 4 947 29 1 2 749 20 508 3 77 3 3 16 81 15 7 8 404 7 1 2 191 12 305 1 3 8 35 5 1 2 140 30 3 8 772 29 5 8 753 Dimensions are to assist you in selecting a log set that is a compatible size Interior Firebox Dimensions Firebox Model 32 36 42 Front Width 31 788 35 889 41 1042 Rear Width 19 1 4 489 23 1 4 591 29 1 4 743 Depth 17 3 8 441 17 3 8 441 17 3 8 4...

Страница 11: ...3 8 1254 Table 1 This Table corresponds to Figures 7 8 and 9 A C D H F G E Rough Framing Face Unfinished Shown Back Wall Of Chase Enclosure Including Finishing Materials If Any Back Wall Of Chase Enclosure Including Finishing Materials If Any Rough Framing Face Unfinished Shown Corner Installation A C G Parallel Installation Figure 8 Figure 9 This Figure corresponds to Table 1 This Figure correspo...

Страница 12: ...ebox for safe operation for model ORIONLR32 series in all installations this part is optional for ORIONLR36 and ORIONLR42 models See Figure 11 These hood kits are design to be fitted to the face of the appliance directly abovethefireboxopening Inadditiontoprovidinganaestheticallypleasing appearance to your appliance the hood reduces heat effects to decora tive mantels and finish materials located ...

Страница 13: ... Repairofminorscratchesanddiscolorationoftheapplianceblackpaintedsurfaces may be accomplished with the touch up paint kit PA I N T APPROVED ACCESSORIES AND COMPONENTS Outside Air Gate Duct Kit Cat No ModelNo Description H3991 OAK UVFRC Outside Air Gate Duct Kit ref Form 750206M Touch Up Paint Kit Cat No ModelNo Description F1882 SCTPSAB Black touch up paint powder coat for firebox face and hood F4...

Страница 14: ...can be found on the rating label located on the bottom left front corner of the appliance If you encounter any problems or have any questions concerning the installation of a Vent Free heater in this system please contact your dis tributorordealerorvisitourwebsiteatIHP us comforreferralinformation No Description OrionLR32WS Cat F4076 OrionLR32WH Cat F4077 OrionLR36WS Cat F4079 OrionLR36WH Cat F408...

Страница 15: ... fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive te...

Страница 16: ...arth Products IHP reserves the right to make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information 1769 East Lawrence Street Russellville AL 35654 P900976 00 ...