NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Installation

900301-01 04/2017

Innovative Hearth Products
Marin™ See-Through B-Vent Gas Fireplaces

Figure 28

SAFETY SWITCH LOCATION (EBVST and EBVPF Safety Switch Location Shown)

MANUALLY-RESET
SAFETY LIMIT SWITCH

FIREBOX SIDE BAFFLE

FIREBOX SIDE BAFFLE SECURING SCREW

FIREBOX

SIDE WALL

CABINET

SIDE WALL

TOP RADIANT PANEL

 AND EYEBROW

BRACKET

SECURING SCREW

SAFETY SWITCH

Step 12. Spillage Test and Safety Limit 
Switch Operation

Spillage Test

After appliance installation, perform this spillage 
test to verify that proper venting conditions exist:

1

 -  Place unit in its normally-operated condi-

tion, that is, with the glass enclosure panels 
in place. 

-  Close all doors and windows in the room. 

Turn on all exhaust fans in the house.

3

 -  Light the appliance.

4

 -  Wait 15 minutes.

5

  -  To check for venting action, start by holding 

a smoke producing device within an inch 
of one edge (side edge, not top or bottom 
edge) of one glass enclosure panel. The 
smoke should be drawn toward the edge 
of the glass enclosure panel. Continue the 
test by moving the smoke producing device 
along the entire length of both side-edges of 
the glass door. Repeat the test for all glass 
enclosure panels.

6

 - 

If the smoke is not drawn towards the edges 
of the glass door turn off the appliance and 
call a qualifi ed service technician.

Manually-Reset Safety Limit Switch

This appliance is equipped with a manually-reset blocked fl ue safety limit switch. Refer to 

Figure 

28

 

for its location. If, during appliance operation, the fl ame goes out (independently of the burner 

on/off wall switch), it may be due to the operation of this safety limit switch.  

First allow the appli-

ance to cool

, then reset the safety switch by pushing the red reset button on the back of the switch.

To access the blocked fl ue safety limit switch

 

refer to

 Figure 28

:

- To access the blocked fl ue safety switch:

1

 -  Remove the hood by pulling directly out from the unit. Remove the front face assembly by 

lifting approximately 1/2" and pulling out from the unit.

-  Reach between the cabinet side and the fi rebox side wall and locate the blocked fl ue safety 

switch.

3

 -  Push the red reset button on the switch.

The appliance should then relight and remain lit.  If this does not occur, 

turn off the appliance and 

call a qualifi ed service technician

.

- To access the blocked fl ue safety switch:

NOTE -

 This procedure should only be performed by a qualifi ed service technician.

Important - Turn electrical power off before beginning this procedure.

1

 -  Open the lower bottom hinged panel on the control side of the fi replace. Remove the modesty 

panel and glass enclosure panel as described on 

Pages 10

 

and

 

21

.

-  Remove the side baffl e securing screws (5) and then remove the baffl e.

3

 -  Remove the safety switch bracket securing screws (2), and pull the switch/bracket assembly 

through the side panel slot.

4

 -  Push the red reset button on the switch.

5

 -  Reinstall the switch/bracket assembly.

6

 -  Reinstall the side baffl e.

7

 -  Reinstall front glass door and front face assembly with barrier.

8

 -  Reinstall the hood.

The appliance should then relight and remain lit.  If this does not occur, check unit for a blocked 
fl ue condition.

TOP OF ASSEMBLY 
AND HOOD

NOTE: Front Face Assembly with barrier installed must be reinstalled 
prior to operation.

Содержание Marin 40STTMN

Страница 1: ...appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Netouchez aucaninterrupteur Nepasvousservir des t l phones se trouvant dans le b timent...

Страница 2: ...ITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas...

Страница 3: ...uncionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quido...

Страница 4: ...e barrier becomes dam aged the barrier shall be re placedwiththemanufacturer s barrier for this appliance For use with barrier s Part No s J7420 INTRODUCTION The Millivolt appliances have a millivolt...

Страница 5: ...TheInstallationmustconformtolocalcodesor in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition InCanada thecurrentCAN CGA B149 1 installation code The appli...

Страница 6: ...ude THE CONVERSION SHALL BE CAR RIED OUT BY A MANUFACTURER S AUTHO RIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANU FACTURER PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTI...

Страница 7: ...so important Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Figure 2 En raison des temp ratures lev es l appareildevrait treinstall dansu...

Страница 8: ...y from the roof surface National Fuel Gas Code ANSI Z223 1 NFPA 54 CAN CGA B149 1 Multiple Terminations These appliances may vent adjacent to and at the same level with any other gas appliances includ...

Страница 9: ...ee Figure 5 Mantels constructed of non combustible materials may be installed at any height above the appliance opening however donotallowanythingtohangbelowthefireplacehood Minimumclearancerequiremen...

Страница 10: ...or detailed procedures Step 1 Page 11 Construct the appliance framing Position the appliance within the framing and secure with nailing brackets and floor anchor tabs Step 2 Page 13 Route gas supply l...

Страница 11: ...nailing flanges Install the 8 nailing flanges as shown in Figure 8 using the existing screws Position the fireplace within the framing When required theflangesmaybebent90degreesby hand or with the ass...

Страница 12: ...19 41 1 8 1045 37 3 4 959 40 1 4 1022 41 1041 37 940 34 1 8 867 23 1 2 597 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top S...

Страница 13: ...mpounds are used in propane applications Be very careful that the pipe compound does not get inside the pipe It is recommended to install a sediment trap in the supply line as close as possible to the...

Страница 14: ...both models A Millivolt Wiring See Figure 14 Install Optional Control Switch OFF ON wall switch or remote control receiver Install snap bushing onbrownwallswitchwire intocontrol switch knock out in s...

Страница 15: ...o the left away from the fireplace The lower control compartment door on the side opposite the valve lifts on and off The millivolt control valve has a 3 8 10mm NPT thread inlet port Secure all joints...

Страница 16: ...loor Joists and under the home to a ventilated crawlspace not considered part of the living area of the home NOTE Do not terminate outside air kit in attic space under any circumstances CAUTION NEVER...

Страница 17: ...any ports are blocked or partially blocked clean out the ports With gas line installed run initial system checkout before closing up the front of the unit Follow the pilot lighting instructions provi...

Страница 18: ...volcanic stone evenly over firebox floor 6 Install Vermiculite Place some vermiculite on the firebox floor around thegrate theentirebagofvermiculitewillNOTbeused DONOTPLACE ANY VERMICULITE ON THE BUR...

Страница 19: ...nst The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide It Against The Back Of The Gra...

Страница 20: ...The Grate Rest Log 5 Against The Grate Here Log 5 Sits In Front Of The Grate STEP 5 NOTICE Marin40ST model fireplac es include barriers to reduce the risk of burns from hot viewing glass The barriers...

Страница 21: ...ring that the gasket seats evenly as the door frame draws shut Fasten the latch located underneath the firebox floor to the door s vee flange Close the latch securely NOTE Front Face Assembly with bar...

Страница 22: ...lation and Page 9 for Clearances Figure 27 Finishing Requirements This Area Must Remain Clear of Combustible Materials Top of Appliance 1 Min 25 mm Combustible Wall Framing Spacer Top of Door Frame Ho...

Страница 23: ...y of the burner on off wall switch it may be due to the operation of this safety limit switch First allow the appli ance to cool then reset the safety switch by pushing the red reset button on the bac...

Страница 24: ...une t l commande est utilis e pour contr ler le foyer nettoyez la soigneusement pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure...

Страница 25: ...r s left side to the right until it disengages from the left corner post hole Pull the door diagonally to the left away from the fireplace Remove the modesty panel by pulling the bottomrightcornerofth...

Страница 26: ...ter to the manifold side pressure test fitting and verify manifold pressure reads 3 5 water column 0 87 kPa for natural gas and 10 0 water column 2 49 kPa for propane gas Step 6 Refer to Figure 31 and...

Страница 27: ...2 todisengage and swing the panel open from top On millivolt systems the piezo igniter Hi Lo flame adjustment knob and pilot and main gas ON OFF control knob are located on the modesty panel The gas...

Страница 28: ...nfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour em...

Страница 29: ...tiquette sur la surface de la plaque de l interrupteur mural quicontr lelefoyer FigureA Choisissezlalangue qui est principalement parl e dans la r sidence du propri taire 2 Si une t l commande est ut...

Страница 30: ...gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appliances are designed to oper ate on natural gas or propane gas only The...

Страница 31: ...ng thefirsttwoweeksofusetopreventthefilmfrom baking on making it very difficult to remove See Cleaning Glass on Page 34 Orifice Sizes Sea Level to High Altitude All Models These appliances are tested...

Страница 32: ...ressure Port Main Gas Control Knob IN OUT SIT Millivolt Gas Valve Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to pr...

Страница 33: ...ly of the burner on off wall switch it may be due to the operationofthissafetylimitswitch Firstallow the appliance to cool then reset the safety switch by pushing the red reset button on it A To acces...

Страница 34: ...before initial use and at least annually by a qualified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged...

Страница 35: ...closure Panel see Figure 38 Retrieve the glass door Visually inspect the gasket on the backside of the frame Gasket surface must be clean free of irregularities and seated firmly Position the door in...

Страница 36: ...evenly over firebox floor 6 Install Vermiculite Place some vermiculite on the firebox floor around the grate the entire bag of vermiculite will NOT be used DO NOT PLACE ANY VERMICULITE ON THE BURNER N...

Страница 37: ...The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide It Against The Back Of The Grate P...

Страница 38: ...2 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots Face The Front Position The Groove In...

Страница 39: ...shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be o...

Страница 40: ...ng conditions are present adjust accordingly If flame appears weak or sooty adjust the air shutter incrementally to a more open position until the proper flame appearance is achieved If flame remains...

Страница 41: ...___________________ Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number...

Страница 42: ...Volcanic Stone Bag of Vermiculite Replacement ember materials volcanic stone or vermiculite are available for use with these appli ances Order kits as part of the periodic maintenance of the applianc...

Страница 43: ...Remote Two Button Timer On Off Or Timer Mode Cat No Model No Description H8860 RC S 1 Remote Control Cost Effective Solution Simple On Off operation Kit includes Remote and Receiver Manual or up to 3...

Страница 44: ...d by long lateral runs too many elbows and or exterior portions of the systembeingexposedtocoldweather Alsoinspectwallstraps or plumbers s tape to ensure it is secure and in place Appliance Checkout Q...

Страница 45: ...AND IMMEDIATELY CALL your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE s F THE PILOT WILL NOT STAY LIT AFTER SEVERAL TRIES TURN THE GAS CONTROL knob to OFF and...

Страница 46: ...LA VEILLEUSE NE RESTE PAS ALLUM E APR S PLUSIEURS TENTATIVES r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fournisseur de gaz 10 Tournez le bouton de r g...

Страница 47: ...ot flame it must impinge on thermocouple see Figure 45 on Page 40 Clean and or adjust pilot for maximum flame impingement on thermocouple Ensure that the connection between the valve and thermocouple...

Страница 48: ...ty 1 Hood Black 40 J7536 2 2 Glass Enclosure Assembly 40 H6365 2 3 Log Set 55M04 1 4 Bag of Vermiculite H6319 1 5 Bag of Embers rockwool 88L53 1 6 Bag of Decorative Volcanic Stone 80L42 1 7 Burner Ass...

Страница 49: ...2017 Innovative Hearth Products Marin See Through B Vent Gas Fireplaces NOTE See the tables on Page 48 for replacement parts applicables REPLACEMENT PARTS Cat No Model F0869 Marin 40STMN 3 2 14 5 6 4...

Страница 50: ...______ _____________________________________________________ _____________________________________________________ _____________________________________________________ _______________________________...

Страница 51: ...t re ood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal u...

Страница 52: ...rices and also to discon tinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2015 Innovative Hearth Products P N 900301 01 Rev D 04 2017 150...

Отзывы: