background image

Astria.us.com

900635-00A

6

NOTICE: Surface temperatures of adjacent 

walls and mantels become hot during opera-

tion. Walls and mantels above the firebox may 

become hot to the touch. If installed properly, 

these temperatures meet the requirement of the 

national product standard. Follow all minimum 

clearances shown in this manual.
NOTICE: If your installation does not meet the 

minimum clearances shown, you must do one 

of the following: 

• operate the logs only with the flue damper 

open

• raise the mantel to an acceptable height

• remove the mantel

FLOOR CLEARANCES

A. If installing appliance on the floor level, you must maintain 

the minimum distance of 14" to combustibles 

(see 

Fig-

ure 6

)

.

B. If combustible materials are less than 14" to the fireplace, 

you must install appliance at least 5" above the combustible 

flooring 

(see 

Figure 7

)

.

Figure 4 - Minimum Mantel Clearances Without Using Hood

14"

Min.

Combustible 

Material 

Noncombustible Material 

Figure 6 - Minimum Fireplace Clearances If Installed at 

Floor Level

Figure 5 - Minimum Mantel Clearances When Using Hood

Minimum Non- 
Combustible  
Material  

Minimum Non- 
Combustible  
Material Height  

Distances to  
Underside of 
Mantel  

Top of Fireplace 
Opening 

Underside of 
Mantel Shelf 

12"

(A) 

18"

20"

22"

24"

All minimum  
distances are 
in inches 

1/2

6" 

8" 

10" 

Mantel Shelf 

Minimum
Noncombustible 
Material 

8"
Min.

12"

15" 18" 20"

1/2

"

6"

8"

10"

12"

Distances to 

Underside of

Mantel 

Hood (GA6050

or GA6053)

Top of
Fireplace
Opening

Underside

of Mantel

Shelf

Mantel Shelf

 

Hearth

5"

Min.

Combustible 

Material 

Figure 7 - Minimum Fireplace Clearances Above 

Combustible Flooring

INSTALLATION

Continued

Determining Minimum Mantel Clearance When Using a 

Hood

If minimum clearances in 

Figure 4

, are not met, you must have 

a hood. When using a hood there are still certain minimum 

mantel  clearances  required.  Follow  minimum  clearances 

shown in 

Figure 5

, when using hood.

INSTALLING DAMPER CLAMP ACCESSORY FOR 

VENTED OPERATION

NOTE

: When used as a vented indoor appliance, appliance 

must be installed only in a solid-fuel burning fireplace with 

a working flue and constructed of noncombustible material.

MANTEL CLEARANCES

In addition to meeting noncombustible material clearances, 

you must also meet required clearances between fireplace 

opening and mantel shelf. If you do not meet the clearances 

listed below, you will need a hood.

Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel shelf and top 

of fireplace opening, a hood is not required 

(see 

Figure 4, 

Page 6

).

Содержание MAGNIFLAMEOD30NE

Страница 1: ...og Appliance Remote Ready Log Set And Burner System Models Models MAGNIFLAMEOD30NE MAGNIFLAMEOD30PE SOUTHERNCOMFORT30A B SOUTHERNCOMFORT36A B SHADYHOLLOW30A B SHADYHOLLOW36A B P N 900635 00 REV A 01 2...

Страница 2: ...nt children from turning on burners with remote WARNING Improper installation adjust ment alteration service or maintenance can cause injury or property damage Refer to this manual for correct install...

Страница 3: ...ance Page 16 8 Before using furniture polish wax carpet cleaner or similar products turn appliance off If heated the vapors from these products may create a white powder residue within burner box or o...

Страница 4: ...appliance Follow all local codes NOTICE State or local codes may only allow operation of this appliance in a vented con figuration Check your state or local codes WARNING Make sure the selector switch...

Страница 5: ...8 up for all models If noncom bustible material is less than 12 you must install the fireplace hood accessory See Figure 3 for minimum clearances If Using Mantel You must have noncombustible material...

Страница 6: ...ide of Mantel Top of Fireplace Opening Underside of Mantel Shelf 12 A 18 20 22 24 All minimum distances are in inches 2 1 2 6 8 10 Mantel Shelf Minimum Noncombustible Material 8 Min 12 15 18 20 2 1 2...

Страница 7: ...provided electric drill with 3 16 masonry drill bit 1 Apply pipe joint sealant lightly to male threads of the 1 2 NPT side of gas fitting elbow provided and connect to inlet side of gas control Remov...

Страница 8: ...ealant that is resistant to liquid petroleum LP gas We recommend that you install a sediment trap in supply line as shown in Figure 12 Locate sediment trap where it is within reach for cleaning Instal...

Страница 9: ...er 5 W C to 10 5 W C Pressure 3 Pressurize supply piping system by either opening pro pane LP supply tank valve for propane LP gas or opening main gas valve located on or near gas meter for natural ga...

Страница 10: ...CONTROL AND BATTERY PACK Figure 16 MF Series Burner System Log Compatibility Chart INSTALLING LOGS AND VOLCANIC STONE WARNING Failure to position the parts in accordance with these diagrams or failur...

Страница 11: ...hadyHollow24 inch models D 060 or SouthernComfort30 and ShadyHollow30 inch models D 018 or SouthernComfort36 and ShadyHollow36 inch models D 026 See Figures 18 18A and 18B Figure 18A shows how the log...

Страница 12: ...he front left log SouthernComfort30 and ShadyHol low30 inch models D 017 or SouthernComfort36 and ShadyHollow36 inch models D 025 See Figures 19 19A and 19B The log has a rectangular stand off on the...

Страница 13: ...Split Log D 021 Middle Split Log D 063 D 021 or D 028 Square Peg Square Grate Log Notch Figure 23 Installing Front Top Log Front Top Log D 024 Rectangular Peg Right Split Crossover Log D 022 Middle Sp...

Страница 14: ...loor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Fol...

Страница 15: ...mote system is ready for use Pushing and holding the LEARN button for 6 seconds will result in clearing the transmitter security code from the module s memory The module will make three long beeps in...

Страница 16: ...er for dust and dirt see Figure 31 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust dirt lint o...

Страница 17: ...ge Orange Orange Red Brown Black Solenoid White Brown Brown Green Igniter Pilot I S AUX AF 5000MOD AF 4000 AF 4000B P Control Module Black Black Option Battery Red SWI SWI GND Black Red HI LO Main Bla...

Страница 18: ...ct igniter cable 2 Free igniter cable if pinched by any metal or tubing Keep igniter cable dry 3 Replace igniter 4 Replace igniter 5 Adjust igniter wires as shown in Figure 28 on Page 15 Replace ignit...

Страница 19: ...air is re moved from line Have gas line checked by local natural or pro pane LP gas company 2 Observe minimum installation clearances see Pages 9 11 3 Clean burner see Cleaning and Maintenance Page 16...

Страница 20: ...Warning state ment at top of page 2 Control valve or gas control de fective 1 The module s internal tempera ture is too high 1 The burner did not successfully ignite 1 Gas leak See Warning state ment...

Страница 21: ...f the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions concerning the installation or application of this appliance please cont...

Страница 22: ...ia us com 900635 00A 22 PARTS MODELS MAGNIFLAMEOD30NE AND MAGNIFLAMEOD30PE 1 2 4 5 6 7 8 9 10 11 12 13 15 16 18 19 20 21 23 24 25 26 22 17 14 8 3 Cat No Model F0561 MAGNIFLAMEOD30NE F0563 MAGNIFLAMEOD...

Страница 23: ...ech 1 J8244 Screw 00 Min Rate Skytech 1 15 J8238 Cap 3 8 Compression 1 16 J4833 T Fitting Brass 3 8 Tube x 3 8 NPT 1 17 J6532 Grate MF42 Stainless Steel 1 J8237 Grate MF48 Stainless Steel 1 18 J4711 F...

Страница 24: ...ssembly The next two numbers indicate the set size 2 6 3 9 1 7 8 5 4 KEY NO PART NO LOG ID NO PART NO LOG ID NO DESCRIPTION QTY 1 J6516 D 019 J6527 D 027 Log Front Right 1 2 J6517 D 018 J6528 D 026 Lo...

Страница 25: ...ted under Replacement Parts on Page 21 of this manual KEY NO CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8254 D 018 J8260 D 026 Log Back Left 1 3 J8255 D...

Страница 26: ...___________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______...

Страница 27: ...damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions pr...

Страница 28: ...er Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials specifications pric...

Отзывы: