Astria Fireplaces MAGNIFLAMEOD24NM Скачать руководство пользователя страница 3

Astria.us.com

126780-01D

3

You must operate this appliance with the fireplace 

screen and hood in place. Make sure fireplace screen 

and hood are in place before running appliance. The 

fireplace screen shall have openings for introduction of 

combustion air.

If used with MFEB accessory ember burner, this appli-

ance shall only be installed in a wood burning fireplace.

 

WARNING: This appliance shall not be installed in 

a room or space unless the required volume of indoor 

combustion air is proved by the method described in 

the National Fuel Gas Code, ANSI Z223.1/NFPA 54, 

the International Fuel Gas Code.

When installing as a vented appliance in a manufac-

tured home or mobile home, the installation must 

conform with the Manufactured Home Construction 

and Safety Standard, Title 24 CFR, Part 3280 or when 

standard is not applicable, with Manufacture Home In-

stallations Standard, ANSI/NCSBCS A225.1/NFPZ 501A.

Any part removed for servicing the appliance must be 

replaced prior to operating the appliance.

SAFETY

  Continued

Children and adults should be alerted to the hazards 

of high surface temperatures and should stay away to 

avoid burns or clothing ignition. Appliance will remain 

hot for a time after shutdown. Allow surfaces to cool 

before touching.

Carefully supervise young children when they are 

in the room with fireplace. When using the remote 

control, keep selector switch in the OFF position to 

prevent children from turning on burners with remote.

Keep the appliance area clear and free from combus-

tible materials, gasoline and other flammable vapors 

and liquids.

 WARNING: Young children should be carefully su-

pervised when they are in the area of the appliance. 

Toddlers, young children and others may be susceptible 

to accidental burns. A physical barrier is recommended 

if there are at-risk individuals in the house. To restrict 

access to a fireplace or stove, install an adjustable safety 

gate to keep toddlers, young children and other at-risk 

individuals out of the room and away from hot surfaces.

2.  Do not place propane/LP supply tank(s) inside any structure. 

Locate propane/LP supply tank(s) outdoors (propane/LP units 

only).

3.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not use any phone in your 

building

• leave the building immediately

• immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions

• if you cannot reach your gas supplier, call the fire department

4.  This appliance shall not be installed in a bedroom or bathroom, 

unless installed as a vented appliance. See Installing Damper 

Clamp Accessory for Vented Operation,  Page 8. This gas log 

set may not be installed as a vented appliance in a bedroom or 

bathroom in the Commonwealth of Massachusetts.

5.  Before installing in a solid fuel-burning fireplace, the chimney flue 

and firebox must be cleaned of soot, creosote, ashes and loose 

paint by a qualified chimney cleaner. Creosote will ignite if highly 

heated. A dirty chimney flue may create and distribute soot within 

the house. Inspect chimney flue for damage. If damaged, repair 

flue and firebox before operating appliance.

Installation and repair should be done by a qualified 

service person. The appliance should be inspected 

before use and at least annually by a qualified service 

person. More frequent cleaning may be required as 

necessary. It is imperative that the control compart-

ment, burners, and circulating air passageways of the 

appliance are kept clean.

1.  WARNING: This appliance is only for use with the type of gas 

indicated on the rating plate. This appliance is not convertible 

for use with other gases. 

 

 WARNING: Fireplace must be operated only with 

doors fully open.

 

WARNING: Vent-free products are prohibited for 

bedroom and bathroom installation in the Common-

wealth of Massachusetts.

WARNING: Do not place log scraps or volcanic 

stone on burner.

Appliance base assembly becomes very hot when 

running appliance. 

Содержание MAGNIFLAMEOD24NM

Страница 1: ...ever use this appliance in an en closed space such as a camper tent car or home DANGER FIRE OR EXPLOSION HAZARD If you smell gas Shut off gas to the appliance Extinguish any open flame If odor continu...

Страница 2: ...ion consult a qualified installer service agency or the gas supplier DANGER Carbon monoxide poisoning may lead to death WARNING This product can expose you to chemi calsincludingCarbonBlack whichiskno...

Страница 3: ...nadjustablesafety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces 2 Do not place propane LP supply tank s inside any structure Locate prop...

Страница 4: ...cts turn appliance off If heated the vapors from these products may create a white powder residue within burner box or on adjacent walls and furniture 9 Do not use this appliance as a wood burning app...

Страница 5: ...than 1 With walls on all sides but with no overhead cover 2 Within a partial enclosure which includes an overhead cover and no more than two side walls These side walls may be parallel as in a breezew...

Страница 6: ...d accessory Even if noncombustible material is more than 12 you may need the hood accessory to deflect heat away from your mantel shelf See Figure 3 and Figures 4 and 5 Page 7 for minimum clearances I...

Страница 7: ...ES In addition to meeting noncombustible material clearances you must also meet required clearances between fireplace opening and mantel shelf If you do not meet the clearances listed below you will n...

Страница 8: ...inches WARNING You must secure this appliance to fire placefloor Ifnot appliancewillmovewhenyouadjust controls Moving appliance may cause a gas leak WARNING Ifinstallinginasunkenfireplace special care...

Страница 9: ...cal codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench approved flexible gas line with gas connector if allowed by local codes...

Страница 10: ...ive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once PRESSURE TESTING APPLIANCE GAS CONNECTIONS 1 Open equipment shutoff valve see Figure 13 2 Open main gas v...

Страница 11: ...rvicepersonmustconnect anddisconnectgastoappliance Followalllocalcodes 2 Carefully remove logs and set aside 3 Locate mounting screws on sides of appliance base assembly and remove screws Set screws a...

Страница 12: ...o Hi check to see if flamescontactanylog Ifso repositionlogsaccording to log installation instructions in this manual Flames contacting logs will create soot INSTALLING LOGS AND VOLCANIC STONE LOG PLA...

Страница 13: ...e base assembly by inserting it from the left side as shown in Figure 19 You will need to twist the log slightly to get it to fit against the burners properly It will rest even with the back edge of t...

Страница 14: ...2A The split side of the log faces forward The log has a notch that fits around the burner tube on the right side The left side of the burner tube fits into the notch on the back side of this log The...

Страница 15: ...ee Figures 25 and 25A The left end of this log has a round hole that fits over the round peg that is on the top of the back left log The rightendofthisloghasarectangularholethatfitsovertherectangular...

Страница 16: ...NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly DO NOT FORCE 5 Wait five 5 minutes to clear out any gas If you then smell gas STOP Follow B in the safety information in...

Страница 17: ...provides a clean burning flame Keep these holes clear of dust dirt lint and pet hair Clean these air inlet holes prior to each heating season Blocked air holes will create soot We recommend that you...

Страница 18: ...Volcanic Stone Page 12 to properly replace logs Replace log s if broken or chipped dime sized or larger MAIN BURNER Periodically inspect all burner flame holes with appliance running All slotted burn...

Страница 19: ...MNF30ONM Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose of input adjustment To Th...

Страница 20: ...cable dry 3 Replace igniter cable 4 Replace igniter 5 Replace pilot assembly 6 Replace pilot assembly 7 Install new alkaline battery in electronic igniter Verify battery is installed correctly Whenig...

Страница 21: ...Maintenance Page 17 or replace ODS pilot assembly 6 Hand tighten until snug then tighten 1 4 turn more 7 Replace pilot assembly 8 Replace control valve Burner does not light after pilot is lit 1 Inlet...

Страница 22: ...7 4 Clean burner see Cleaning and Main tenance Page 17 or replace burner orifice s White powder residue forming within burner box or on adjacent walls or furniture 1 When heated vapors from furniture...

Страница 23: ...ontrol defective 1 Locate and correct all leaks see Checking Gas Connections Page 10 2 Replace control valve or gas control Gas odor during combustion 1 Foreign matter between control valve and burner...

Страница 24: ...place Fits openings 28 to 48 wide RECEIVER AND HAND HELD REMOTE CONTROL KIT MRC REMOTE READY MODELS ONLY Cat No F1077 Model MRC For all models Allows the fireplace to be turned on and off by using a h...

Страница 25: ...13 14 15 16 17 18 19 20 21 23 24 25 22 11 12 12 7 3 4 Cat No Model F0558 MagniFlameOD24NM F0560 MagniFlameOD24PM F0562 MagniFlameOD30NM F0564 MagniFlameOD30PM WARNING Failure to position the parts in...

Страница 26: ...er 1 16 J5198 Shutter Air NG 1 J5199 Shutter Air LP 1 17 J3604 Orifice 0 12 NG 1 J3615 Orifice 0 07 LP 1 18 J6127 Orifice Holder 90 Degrees 1 19 J4733 Nut and Sleeve Brass Compression 1 20 J4711 Tube...

Страница 27: ...9 1 7 8 5 4 KEY NO CAT NO Log Id CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J6696 D 061 J6516 D 019 J6527 D 027 Log Front Right 1 2 J6697 D 060 J6517 D 018 J6528 D 026 Log Back Left 1 3 J6698 D 05...

Страница 28: ...k Left 1 3 J8247 D 059 J8255 D 017 J8261 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J8248 D 063 J8256 D 021 J8262 D 028 Log Middle Split 1 6 J8249 D 022 J8257 D 022 J...

Страница 29: ...have any questions concerning the installation or application of this appliance please contact your dealer IHP 1769 East Lawrence Street Russellville AL 35654 Visit us at Astria us com SERVICE HINTS...

Страница 30: ...____________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______...

Страница 31: ...damage to the Product will produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions pr...

Страница 32: ...name Printed in U S A 2015 Innovative Hearth Products P N 126780 01 Rev D 11 2019 Innovative Hearth Products IHP reserves the right to make changes at any time without notice in design materials speci...

Отзывы: