IMPORTANT:

 Vent-free gas log heaters add 

moisture to the air. Although this is beneficial, 

installing  firebox  in  rooms  without  enough 

ventilation air may cause mildew to form from 

too much moisture. See 

Air for Combustion 

and Ventilation

, page 8. 

IMPORTANT:

 Make sure firebox is level. 

If  firebox  is  not  level,  log  set  will  not  work 

properly. 

Note: Your firebox is designed to be used in 

zero clearance installations. Wall or framing 

material can be placed against any exterior 

surface on the rear, sides, top or bottom of 

your firebox, except where standoff spacers 

are integrally attached. If standoff spacers are 

attached to your firebox, these spacers can 

be placed directly against wall or framing ma

-

terials. Use the dimensions shown for rough 

opening to create the easiest installation.

Use  dimensions  shown  for  rough  openings 

to create the easiest installation (see 

Built-In 

Firebox Installation

, page 12).

INSTALLATION CLEARANCES

 WARNING: Maintain the 

minimum clearances. If you can, 

provide greater clearances from 

floor, ceiling and adjoining wall.

Carefully follow these instructions. This will 

ensure safe installation.

Minimum Wall and Ceiling Clearances (see 

Figure 6)

A.  Clearances from the side of fireplace 

cabinet to any combustible material and 

wall should follow diagram in Figure 6.

 

Example:

 The face of a mantel, bookshelf, 

etc. is made of combustible material and 

protrudes 3 

1

/

2

" from the wall. This com-

bustible material must be 4" from the side 

of the fireplace cabinet (see Figure 6).

B.  Clearances from the top of firebox opening 

to ceiling should not be less than 42".

C.  When firebox is installed on carpeting or 

other combustible material, other than 

wood flooring, firebox should be installed 

on a metal or wood panel extending the 

full width and depth of enclosure.

D.  Clearances from bottom of firebox to the 

floor is 0".

These fireboxes can be installed as freestand-

ing  units  against  a  wall  with  the  approved, 

INSTALLATION

Continued

*Minimum 16" from Side Wall 

*

optional cabinet mantels (see 

Accessories

page 22) or as a built-in unit. Clearances are the 

same for either installation method. 

 CAUTION: Do not install 

the  firebox  directly  on  carpet 

or vinyl. 

Example

Mantel Clearances for Built-In Installation

If placing custom mantel above built-in firebox, 

you must meet the minimum allowable clear-

ance between mantel shelf and top of firebox 

opening shown in Figure 7, page 12. These 

are the minimum allowable mantel clearances 

for a safe installation. Use larger clearances 

wherever possible to minimize the heating of 

objects and materials placed on the mantel.

 CAUTION: Do not allow the 

vent-free gas log heater to touch 

or extend beyond the fireplace 

screen.

NOTICE: Surface temperatures 

of adjacent walls and mantels 

become hot during operation. 

Walls and mantels above the 

firebox  may  become  hot  to 

the touch. If installed properly, 

these temperatures meet the 

requirement of the national 

product standard. Follow all 

minimum clearances shown in 

this manual.

Figure 6 - Minimum Clearance for 

Combustible to wall 

f i r e - p a r t s . c o m

Содержание Astria Vega32ZP2

Страница 1: ...ay result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SM...

Страница 2: ...assemble operate or service this heater Improper use of this fireplace can cause serious injury or death from burns fire explo sion electricalshockandcarbon monoxide poisoning WARNING Any change to t...

Страница 3: ...ed under dusty conditions 6 Do not use this firebox to cook food or burn paper or other objects 7 Turn firebox off and let cool before servic ing Only a qualified service person should service and rep...

Страница 4: ...ect the performance of the fireplace or vent free gas logs OPTIONAL FIBER AND PORCELAIN LINERS For a vintage look the fiber panels give a old masonry brick look and are light weight and easy to instal...

Страница 5: ...10 517 3 518 3 282 8 152 6 866 13 119 8 132 3 522 8 152 10 457 23 919 12 564 16 586 19 461 4 366 6 039 22 444 PRODUCT SPECIFICATIONS Figure 1 Product Specifications 32 Models Right Side View Left Sid...

Страница 6: ...49 20 962 8 063 7 410 8 513 11 492 3 277 2 550 8 175 8 525 8 331 8 175 13 892 10 349 24 934 21 081 6 043 29 101 26 366 40 250 Right Side View Left Side View Front View Firebox Top View 36 MODELS Figur...

Страница 7: ...2 281 3 120 44 253 7 564 10 532 13 369 2 520 8 153 3 265 10 768 10 436 2 523 8 153 14 233 12 582 50 045 23 216 4 479 6 028 36 143 27 117 Right Side View Left Side View Front View Firebox Top View 42 M...

Страница 8: ...rectly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the un confined space Adjoining rooms are communicating only if there are...

Страница 9: ...rs and vents to the outdoors Example Gas water heater __________ Btu Hr Vent free heater _________ Btu Hr Total _________ Btu Hr AIR FOR COMBUSTION AND VENTILATION Continued 4 Compare the maximum Btu...

Страница 10: ...size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermo stat controlled power vent Heated air entering the attic will activate t...

Страница 11: ...all This com bustible material must be 4 from the side of the fireplace cabinet see Figure 6 B Clearances from the top of firebox opening to ceiling should not be less than 42 C When firebox is instal...

Страница 12: ...Height Figure 8a Figure 8b Figure 8c Figure 8d NOTICE Ifyourinstallationdoes not meet the minimum clear ances shown you must do one of the following raise the mantel to an accept able height remove t...

Страница 13: ...nt facing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing INSTALLATION Continued Figure 9 Attaching Firebox to Wall Studs Model May Vary From Illustration Nailing Flang...

Страница 14: ...he firebrick concrete insert Figure 11 Location of Knockout for Gas Line Knockout Chisel Firebrick Side Wall Remove this Area Side View INSTALLING OPTIONAL BLOWER ACCESSORIES NOTICE The firebox identi...

Страница 15: ...you intend to gain access into the bottom rear of the firebox to install the blower accessory The lower front panel can be removed easily by snapping out the front with a flat blade screwdriver Use c...

Страница 16: ...ire routing is not pinched or in a precarious position Correct accordingly INSTALLATION Continued Model BK Installation 1 Be certain that all wire terminals are securely attached to terminals on blowe...

Страница 17: ...tion Turn blower off by turning knob fully coun terclockwise before continuing 9 Peel off backing paper and stick supplied wiring diagram decal on firebox bottom approximately 12 in front of blower se...

Страница 18: ...n Turn blower off before continuing 8 Peel off backing paper and stick supplied wiring diagram decal on firebox bottom approximately 12 in from of blower see Figure 18 page 17 9 Replace all panels and...

Страница 19: ...ed through a vented crawl space AK4F or through a sidewall AK4 See Figure 21 CAUTION Combustion air inlet ducts shall not terminate in attic space Figure 21 Outside Air Kit Secure to Collars with Meta...

Страница 20: ...of firebox and fasten using remaining Phillips screw LOCATING ACCESS COVER PLATE Sheet metal cover plates located underneath front hearth refractory if included may have shifted or moved out of place...

Страница 21: ...0 655 2008 When calling have ready your name your address model and serial numbers of your heater how heater was malfunctioning purchase date Usually we will ask you to return the part to the factory...

Страница 22: ...ide additional air to reduce build up of condensation that occurs in today s tightly constructed homes AK4F Outside Air Kit for Floor Installation AK4X Collar and Hood accepts any length of 4 flex tub...

Страница 23: ...ssic C32GO 32 Oak Stain Georgian 36 WALL MANTELS W36TU 36 Unfinished Traditional W36TO 36 Oak Stain Traditional 36 CORNER MANTELS C36TU 36 Unfinished Traditional C36TO 36 Oak Stain Traditional UNIVERS...

Страница 24: ...www Astria US com 126694 01B 24 1 2 3 4 5 6 7 8 PARTS MODELS 32 36 AND 42 fire parts com...

Страница 25: ...sh Face 42 VF Firebox White Stacked Brick VEGA42ZP2 F0404 Louver Face 42 VF Firebox White Stacked Brick VEGA42ZP2 F0405 Flush Face 42 VF Firebox Red Stacked Brick VEGA42ZP2 F0406 Louver Face 42 VF Fir...

Страница 26: ...www Astria US com 126694 01B 26 1 2 3 4 5 6 6 PARTS MODELS Vega32ZP2 Vega36ZP2 Vega36ZP3 Vega42ZP2 and Vega42ZP3 fire parts com...

Страница 27: ...ck 1 125286 02 Right Refractory Red Herringbone 1 125296 02 Right Refractory Red Herringbone 1 3 108430 01 Rear Refractory White Stack 1 125282 01 Rear Refractory White Stack 1 125292 01 Rear Refracto...

Страница 28: ...product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep receipt for...

Страница 29: ...r acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Pro...

Страница 30: ...NOTES 30 fire parts com...

Страница 31: ...NOTES 31 fire parts com...

Страница 32: ...in design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126694 01 Rev B 0...

Отзывы: