![Astria Fireplaces Aries 33 Series Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/astria-fireplaces/aries-33-series/aries-33-series_manual_2990880037.webp)
Installation
900923-00A, 09/2019
Innovative Hearth Products
Aries™ Direct-Vent Fireplaces
37
Ground: green Neutral: white 120 V
AC: black
Wall-mounted ON/
OFF blower switch
or variable speed
control switch
*
Junction
box
Tab
broken
Hot side of
receptacle
Neutral side
of receptacle
Green ground screw
Tab
intact
Field wired
Factory wired
Blower
Ground
Plug blower into
this receptacle
Red
Black
Green
White
1.
If installing an ON/OFF wall switch or thermostat, mount it in a convenient location on a wall near the fireplace.
2.
Wire the control switch within the millivolt control circuit using the 15 ft of 2-conductor wire supplied with the
unit
(
Figure 31
).
NOTE:
The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and
the other end of each conductor placed loose inside the bottom compartment.
CAUTION
In millivolt systems, do NOT connect a wall switch to a 120 V power supply.
TP-TH
TP
TH
APPLIANCE- MOUNTED
ON/OFF SWITCH
(OPTIONAL)
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
JUNCTION BOX
BLACK
W
GR
120 V
AC
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
BK
R
THERMOPILE
GAS VALVE
FAN
(OPTIONAL)
Figure 32 - Wiring Diagram - Millivolt Gas Valves
Figure 33 - Junction Box Wiring, 120 V, 60 hz, 1 phase