21
•
Polarity Inversion Duration menu -
display :
dUr
(only the Selwatch model
T
ype
3-03, 3-04
and
3-05)
By default, the device displays
4
. The polarity
of the electrodes is inverted every four hours.
In the event of problems with the electrodes,
you may change the duration of the cycle
(askyour technician for advice).
•
Amperage menu -
display :
INT
(only the Selwatch model 3
T
ype
3-03, 3-04
and
3-05
)
By default, the device is set to
10
amperes and
displays 10. You may change the amperage if
there are problems with the electrodes (ask
your technician for advice about this).
The display shows a value of between 1 and 10.
•
Reset menu -
display :
rCL
(only for the analysis values)
Press
C
Cl
twice to return the whole Chlorine
menu to its default settings.
•
ACL menu
This menu is for technical support only, so do
not change anything in it. Press
C
Cl
for three
seconds to exit the menu.
At the end of the countdown,
the device displays
NOR
.
You may:
•
Launch a top-up chlorination
(over-production
of chlorine) Press
Cl
+
for five seconds. The
display shows CLC. Chlorination will be
accelerated for five hours until a maximum
chlorine content of 4 ppm is obtained.
•
Place the regulation function on standby
(by-pass)
Press
+
for 10 seconds
The display shows
Byp
. Press
+
again for 10
seconds to put the electrolyser or chlorine meter
pump back in regulated mode.
•
Press
+
to stop the countdown.
This will trigger a chlorine and pH analysis
request (without changing anything). Switch
the machine off and then on again to restart
the countdown, if you so wish.
Common functions
Programming the Chlorine and pH menu..
•
Adjust the chlorine and pH settings
The dial always shows the true chlorine content
and pH of your swimming pool.
Press and hold down
C
Cl
or
C
pH
to see th
requested setting value on the dial. Then increase
or decrease the value using the
+
and buttons.
The device is set to 1.5 ppm for the chlorine
and 7.4 for the pH by default.
•
Launch an immediate and forced analysis
Press
C
Cl
or
C
pH
for three seconds (valid only
if the device has undertaken three or four
analyses).
•
Control the reagents level
Press
C
Cl
or
C
pH
for five seconds then read
the display:
IIIIII
: there are more than 1.000 analyses left.
999
to
099
: indicates the number of remaining
analyses.
999
to
099
(flashing): warning that there is no
more reagent.
Press
C
Cl
or
C
pH
for 3 seconds to leave the menu.
Note: the device can still make several more
analyses once the counter reaches zero.
Press
C
Cl
or
C
pH
then the
+
and buttons
to reset the counter to zero. When the display
flashes, press
C
Cl
or
C
pH
twice.
•
Display the most recent contents measured
Press
C
Cl
or
C
pH
for eight seconds. If no content
value is available, the display indicates
---
.
pH menu
Press… to enter
the pH menu
C
pH
then
+
Press… to navigate
the menu
C
pH
then press
+
to
switch from one
setting to another
Press… to enter
a setting and change it
C
pH
then
+
or to
change the value
Press ... for three
seconds to validate
and exit the pH menu
C
pH
ENGLISH