Astralpool P320 XT P520 XT Скачать руководство пользователя страница 8

9

viron xt series 2 pumps   

Installation Manual

8

viron xt series 2 pumps   

Installation Manual

Section 3.  Getting Started

Install the Viron XT Series 2 Pump in accordance with 

the procedures in this manual, local codes and 

ordinances, and in accordance with the latest edition 

of the appropriate national code. See Section 4.2.

This manual provides the information needed to meet 

these requirements. Review all applications and 

installation procedures before continuing the 

installation.

3.1 

Contents

Before starting, check that you have the correct parts as 

indicated in Table 1. If any parts are missing or incorrect, 

please call your local distributor or technical support at 

1300 186 875 for assistance.

1

2*

3*

4*

*  XT pump shown with union nut, union tail and o-rings installed.

Figure 3. 

Viron XT Series 2 Pump Components

Item

Description

Quantity

1

Viron XT Series 2 Pump

1

2

50 mm Union Nut

2

3

50mm Universal Union Tail

2

4

50mm Universal Union O-ring

2

Table 1.  XT Pump Parts

3.2 

Technical Specifications

•  Power: P320XT - .85 Kw output, 240V 50 Hz, 7.5 Amp, 

max speed 2850 rpm; P520XT - 1.5 Kw output,240V 

50 Hz, 8.0 amp, max speed 2850 rpm 

• 

Opera� on from 600 to 2850 rpm + overdrive 

(se�  ngs per 25 rpm step)

• 

Number of programmable speeds: 3

• 

Number of programmable � mer se�  ngs: 4 per day

• 

Flow rate at 8 metres hydraulic head: 120 to 

200 litres/Minute at 2850 RPM

• 

Opera� ng temperatures: from 2 to 50°C air, and 2 to 

35°C water

• 

Protec� on index: IPX5

3.3 

Required Equipment

Please ensure that the following equipment is 

available to the installer at the time of installation.

3.3.1 

Required Tools

Safety Eye Wear

Gloves

Philips

Screwdriver

Flathead

Screwdriver

Pipe Wrench

Adjustable

Wrench

5mm (3/16”)

Hex Key

Multi Grips

Digital Differential

Manometer

Voltage Meter PVC Pipe Cutter

Tape Measure

Power Drill

Figure 4. 

Required Tools

Содержание P320 XT P520 XT

Страница 1: ...standards and any other local applicable regulations Before installing this product read and follow all warning notices and instructions that accompany this product Failure to follow warning notices...

Страница 2: ...R MODEL CONTROL PANEL MODEL SERIAL NUMBER NOTES For full warranty terms and conditions and to register your warranty simply visit www astralpool com au warranty and complete your details Or scan the Q...

Страница 3: ...1 Normal Operation 14 5 2 Starting Up the Pump 14 5 3 Pump Lid Removal 14 5 4 Conduct Pressure Test 15 Section 6 Viron XT Series 2 Pump Controls 16 6 1 Viron XT Series 2 Pump Control Panel 16 6 2 Spee...

Страница 4: ...ceptable standard WARNING To reduce the risk of property damage or injury do not attempt to change the backwash multiport slide or full flow valve position with the pump running WARNING AstralPool Pum...

Страница 5: ...e pump dry for any length of time will cause severe damage and will void the warranty WARNING To minimize risk of severe injury or death the filter and or pump should not be subjected to the piping sy...

Страница 6: ...3 feet apart centre to centre See Figure 1 The system must be built to include at least two 2 suction outlets drains connected to the pump whenever the pump is running However if two 2 suction outlet...

Страница 7: ...rate for your pool In addition special applications such as in floor cleaning or programming water features are enabled using the time clock and speed selection for different times of day The P520XT...

Страница 8: ...iption Quantity 1 Viron XT Series 2 Pump 1 2 50 mm Union Nut 2 3 50mm Universal Union Tail 2 4 50mm Universal Union O ring 2 Table 1 XT Pump Parts 3 2 Technical Specifications Power P320XT 85 Kw outpu...

Страница 9: ...ive feet horizontally from the edge of the pool and or spa Choose a location that will minimize turns in the piping 2 Place the pump on a solid foundation that will not vibrate To further reduce the p...

Страница 10: ...from only one main drain At least two main drains must be connected to the pump when it is in operation However if two main drains run into a single suction line the single suction line may be equipp...

Страница 11: ...IF USING A DIFFERENT BRAND HEATER All pool suction outlets and plumbing must be properly installed in compliance with applicable entrapment protection standards such as AS2610 2 Listed certified to t...

Страница 12: ...e not to exceed 45 degrees 7 Pumps must be either supplied by an isolating transformer or supplied through a residual current device RCD with a rated residual operating current not exceeding 30mA 4 4...

Страница 13: ...d by these devices The Viron P320XT and P520XT must have its in built timer deactivated if the pump operating times and speeds are to be operated by the compatible AstralPool Salt Chlorinator EQ RolaC...

Страница 14: ...the user interface display Viron XT Series 2 Pump primes 30 faster than conventional maximum speed Viron XT Series 2 Pump automatically limits maximum speed according to the system s total dynamic hea...

Страница 15: ...in death serious injury or property damage Be sure all air is properly purged out of the system before operating DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR LEAKS WARNING ELECTRICAL SHOCK...

Страница 16: ...special purpose flow rates may include but are not limited to operating spa jets operating water falls or water features operating a suction pool cleaner High Speed is generally set up to backwash you...

Страница 17: ...gain to set minutes and then press enter again to set AM or PM 5 Press Auto Power button to accept 6 The LCD screen will quickly flash 3 times to indicate the new setting has been accepted 6 3 3 Setti...

Страница 18: ...d above normal high speed We recommend high speeds for Priming 4 PRIMING TIME will now appear on the screen Prime period is defaulted to 5 minutes and high speed Use the up and down arrows to change t...

Страница 19: ...ods deactivated Pump speed can be changed from pump or controller 240V Power 24V Communication Data VX Salt Chlorinator TIMER CLOCK DAY Chlorine Output Set Point Decrease SAFETY BACKWASH POOL MODE SPA...

Страница 20: ...16 Viron XT Series 2 Pump with RJ12 Cable Connection Viron XT Series 2 Pump is connected to Viron Heater or Other Compatible AstralPool Heater via RJ12 cable Viron Heater Status Viron XT Series 2 Pump...

Страница 21: ...re release valve on the filter and make sure it is clean and ready for operation 10 Turn on the power to the pump Once all the air has been evacuated from the filter close the pressure release valve 7...

Страница 22: ...n the surfaces surrounding the control to prevent ant and insect ingress Repeat every three months or as necessary Note Regular maintenance is important to ensure long life and trouble free performanc...

Страница 23: ...nter season or other scheduling conflicts Check for debris build up in the skimmer basket This can cause reduced flow to the pump Also ensure that any suction cleaners are disconnected as this can be...

Страница 24: ...24 viron xt series 2 pumps Installation Manual Section 9 Spare Parts 9 1 Series 2 Model P320XT and P520XT 1 2 9 10 11 12 13 8 14 3 5 7 21 22 17 18 16 19 23 20 15 4 6...

Страница 25: ...NG SEAL PLATE 70030 1 1 13 SEAL PLATE SP40030 1 1 14 SEAL PLATE TO WET END BOLTS 40175 6 6 15 MOTOR RETAINING BOLT 40173 4 4 15 M8 HEX BRASS NUT 40272 6 6 16 MOTOR FOOT 4005002 1 1 16 MOTOR FOOT RUBBE...

Страница 26: ...TOP TIME TIMER 4 START TIME TIMER 4 STOP TIME CURRENT TIME LOW MED HIGH TIMER 2 LOW SPEED TIMER 2 MED SPEED TIMER 2 HIGH SPEED LOW MED HIGH TIMER 3 LOW SPEED TIMER 3 MED SPEED TIMER 3 HIGH SPEED LOW M...

Страница 27: ...ow Rate L min Overdrive High Speed 2850 RPM Medium Speed 2000 RPM Low Speed 1325 RPM 0 100 200 300 400 500 0 0 5 0 10 0 15 0 20 0 25 0 11 2 Series 2 Model P520XT Total Head m Flow Rate L min Overdrive...

Страница 28: ...2020 Fluidra S A All rights reserved This document is subject to change without notice Fluidra Group Australia 219 Woodpark Road Smithfield NSW 2164 Australia 1 300 186 875 www astralpool com au...

Отзывы: