Astralpool KIVU 56633 Скачать руководство пользователя страница 9

ENGLISH

10

KIVU PUMP

 - ASTRALPOOL

MAXIMUM FLOW RATE

-  The maximum flow rate is determined by the minimum differential pressure of the pump. The minimum pressure should 

never be less than that indicated on the pump label. (Fig.4)

MINIMUM FLOW RATE

-  The pump should not work against a closed discharge valve, as this would cause an increase in temperature which could 

damage parts of the pump and shorten its useful life.

-  The continuous minimum flow rate must be at least 10% of the nominal flow rate indicated on the pump label. (Fig.4).

9. MAINTENANCE

-   For regular control:

• Check that the mechanical parts are tightly secured and check the condition of the screws supporting the machine.
• Clean the pre-filter basket regularly to avoid drops in pressure. To prevent the basket from breaking, do not hit it 

during the cleaning process.

• The pump should be checked every 100 hours of operation or less, depending on the level of cleanliness of the water.
• Check the temperature of the machine and the electric motor. In the event of a fault, stop the machine immediately and 

contact the nearest Technical Assistance Service.

• Check for machine vibrations. In the event of a fault, stop the machine immediately and contact the nearest Technical 

Assistance Service. 

-   Should the pump stop, check that consumption of the running motor in amperes is equal to or below that indicated on 

the manufacturer’s characteristics plate. If this information is available, contact the nearest Technical Assistance Service.

-   Empty the pump if it is to remain at a standstill for a certain length of time, especially in cold countries where there is a 

risk of freezing.

-   Remove the purge cap to empty the pump.
-   Every time the pre-filter is opened, clean the seal and its seating of any impurities to ensure airtightness when the cap 

is closed.

-   Pump components that, due to their normal use, suffer wear and/or tear must be regularly replaced to ensure good pump 

performance. The following table shows the perishables and/or consumables used in the pump and their estimated 

working life.

COMPONENT DESCRIPTION

ESTIMATED WORKING LIFE

O rings and general seals

1 year

Mechanical seal

1 year

Bearings

1 year

The estimated working life of the parts above has been established according to normal product use and installation conditions.
Follow the instructions in the installation manual to maintain the working life of the pump.

10. REMOVAL

-   The motor unit can be removed from the pump body without having to disconnect the pump’s suction and return pipes.
-   To remove the Motor unit from the pump body, remove the screws joining them together.

Содержание KIVU 56633

Страница 1: ...ES ISTRUZIONI ORIGINALI ORIGINALANLEITUNG INSTRU ES ORIGINAIS CENTRIFUGAL PUMP FOR SWIMMING POOLS POMPES CENTRIFUGE POUR PISCINES BOMBAS CENTR FUGAS PARA PISCINAS POMPE CENTRIFUGHE PER PISCINE ZENTRIF...

Страница 2: ...ccessories authorised by the manufacturer ensure greater safety The pump manufacturer is exempt from all liability regarding any damage caused by unauthorised spare parts or accessories When working o...

Страница 3: ...ine is running and or before it comes to a complete standstill Wait for the machine to come to a halt before handling it Before any electrical or mechanical maintenance operation disconnect the unit f...

Страница 4: ...motor one on the cover of the terminal box and another on the fan cover LABEL ON THE COVER OF THE TERMINAL BOX It provides information on the hydraulic characteristics of the pump Fig 4 Ref Pump code...

Страница 5: ...ing and receives dry ventilation 6 INSTALLATION AND ASSEMBLY Our pumps may only be assembled and installed in pools or ponds that are compliant with HD 384 7 702 Should you have any doubts please cons...

Страница 6: ...ut off valves on both sides of the pump to prevent the system from emptying if we have to clean or repair the pump Check that the pipes are held in place as close as possible to the pump both on the s...

Страница 7: ...itable mains connections involve the risk of electrocution For pumps with a three phase motor Use a motor guard with magneto thermal protection Protect the pump against overloads with a cut off switch...

Страница 8: ...rew on tight not forgetting to fit the seal in its housing 5 Check that the mains voltage and frequency correspond with those indicated on the pump characteristics plate The pumps must not be run with...

Страница 9: ...mmediately and contact the nearest Technical Assistance Service Should the pump stop check that consumption of the running motor in amperes is equal to or below that indicated on the manufacturer s ch...

Страница 10: ...tor turning Invert 2 power phases Wrong voltage Check the voltage on the characteristics plate and that of the mains Pre filter blocked Clean the filter Load loss in the installation Prevent parts fro...