Astralpool KIVU 56633 Скачать руководство пользователя страница 1

KIVU MANUAL
MANUEL KIVU
MANUAL KIVU
MANUALE KIVU
KIVU MANUELL
MANUAL KIVU

ORIGINAL INSTRUCTIONS

INSTRUCTIONS D’ORIGINE

INSTRUCCIONES ORIGINALES

ISTRUZIONI ORIGINALI

ORIGINAL

ANLEITUNG

INSTRUÇÔES ORIGINAIS

CENTRIFUGAL PUMP FOR SWIMMING POOLS
POMPES CENTRIFUGE POUR PISCINES
BOMBAS CENTRÍFUGAS PARA PISCINAS
POMPE CENTRIFUGHE PER PISCINE
ZENTRIFUGALPUMPEN FÜR SCHWIMMBECKEN
BOMBAS CENTRÍFUGAS PARA PISCINAS

K I V U

63042 / 63043 / 63044

66047 / 66048 / 66049

56633 / 56634 / 56635 / 56637 / 56638 / 56639

Содержание KIVU 56633

Страница 1: ...ES ISTRUZIONI ORIGINALI ORIGINALANLEITUNG INSTRU ES ORIGINAIS CENTRIFUGAL PUMP FOR SWIMMING POOLS POMPES CENTRIFUGE POUR PISCINES BOMBAS CENTR FUGAS PARA PISCINAS POMPE CENTRIFUGHE PER PISCINE ZENTRIF...

Страница 2: ...ccessories authorised by the manufacturer ensure greater safety The pump manufacturer is exempt from all liability regarding any damage caused by unauthorised spare parts or accessories When working o...

Страница 3: ...ine is running and or before it comes to a complete standstill Wait for the machine to come to a halt before handling it Before any electrical or mechanical maintenance operation disconnect the unit f...

Страница 4: ...motor one on the cover of the terminal box and another on the fan cover LABEL ON THE COVER OF THE TERMINAL BOX It provides information on the hydraulic characteristics of the pump Fig 4 Ref Pump code...

Страница 5: ...ing and receives dry ventilation 6 INSTALLATION AND ASSEMBLY Our pumps may only be assembled and installed in pools or ponds that are compliant with HD 384 7 702 Should you have any doubts please cons...

Страница 6: ...ut off valves on both sides of the pump to prevent the system from emptying if we have to clean or repair the pump Check that the pipes are held in place as close as possible to the pump both on the s...

Страница 7: ...itable mains connections involve the risk of electrocution For pumps with a three phase motor Use a motor guard with magneto thermal protection Protect the pump against overloads with a cut off switch...

Страница 8: ...rew on tight not forgetting to fit the seal in its housing 5 Check that the mains voltage and frequency correspond with those indicated on the pump characteristics plate The pumps must not be run with...

Страница 9: ...mmediately and contact the nearest Technical Assistance Service Should the pump stop check that consumption of the running motor in amperes is equal to or below that indicated on the manufacturer s ch...

Страница 10: ...tor turning Invert 2 power phases Wrong voltage Check the voltage on the characteristics plate and that of the mains Pre filter blocked Clean the filter Load loss in the installation Prevent parts fro...